AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Feygelman, V. M.
Right arrow Articles by Peters, K. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Feygelman, V. M.
Right arrow Articles by Peters, K. R.

American Journal of Neuroradiology, Vol 13, Issue 3 845-849, Copyright © 1992 by American Society of Neuroradiology


ARTICLES

Effective dose equivalents to patients undergoing cerebral angiography

VM Feygelman, W Huda and KR Peters
Department of Radiology, JHMHC, University of Florida College of Medicine, Gainesville 32610-0374.

PURPOSE: To determine values of the effective dose equivalent, HE, for patients undergoing diagnostic cerebral angiography and compare these values with radiation doses received by patients undergoing other diagnostic examinations of the head. METHODS: The radiographic techniques for ten patients undergoing cerebral angiography were recorded and used to obtain the product of the entrance skin dose and the x-ray beam cross-sectional area. These measured dose-area product data were converted into effective dose equivalents employing published conversion factors which take into account the part of the patient anatomy irradiated and the radiographic technique factors employed. RESULTS: The average patient HE value was 10.6 mSv, with a range of 2.7- 23.4 mSv. Fluoroscopy contributed approximately 67% of the total HE, with cut films and digital subtraction angiography contributing 26% and 7%, respectively. CONCLUSIONS: The radiation doses (HE) to patients undergoing diagnostic cerebral angiography are comparable to the patient doses in nuclear medicine brain studies where the typical HE is approximately 10 mSv. In CT, the patient dose is approximately 2 mSv, whereas in plain skull x-ray examinations, the patient dose is much lower at approximately 0.15 mSv.


This article has been cited by other articles:


Home page
RadiologyHome page
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Radiology, July 1, 2008; 248(1): 254 - 263.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
P. M. Meyers, V. V. Halbach, A. M. Malek, C. C. Phatouros, C. F. Dowd, M. T. Lawton, T. E. Lempert, and R. T. Higashida
Endovascular Treatment of Cerebral Artery Aneurysms during Pregnancy: Report of Three Cases
AJNR Am. J. Neuroradiol., July 1, 2000; 21(7): 1306 - 1311.
[Abstract] [Full Text] [PDF]