American Journal of Neuroradiology, Vol 16, Issue 2 281-288, Copyright © 1995 by American Society of Neuroradiology
ARTICLES |
MR evaluation of vertebral metastases: T1-weighted, short-inversion- time inversion recovery, fast spin-echo, and inversion-recovery fast spin-echo sequences
RC Mehta, MP Marks, RS Hinks, GH Glover and DR Enzmann
Department of Radiology, Stanford University Medical Center, CA 94305- 5105, USA.
PURPOSE: To compare the detectability of vertebral metastatic disease on T1-weighted, short-inversion-time inversion recovery (STIR), fast spin-echo (FSE), fat-saturated FSE, and inversion recovery FSE (IRFSE) MR sequences using percent contrast and contrast-to-noise ratios. METHODS: Patients with proved metastatic disease underwent imaging on a 1.5-T MR system with sagittal T1-weighted (800/20/2 [repetition time/echo time/excitations]) (91 patients), STIR (1400/43/2; inversion time, 140) (91 patients), FSE (4000/180/2) (46 patients), fat-saturated FSE (4000/180/2) (16 patients), and IRFSE (29 patients) sequences. Percent contrast and contrast-to-noise ratio were calculated for the lesions. The number of metastatic lesions detected with each of the pulse sequences was also calculated. RESULTS: Mean percent contrast was, for T1-weighted sequence, -42.2 +/- 1%; STIR, 262 +/- 34%; FSE, 121 +/- 21%; fat-saturated FSE, 182 +/- 6%; and IRFSE, 272 +/- 47%. The mean contrast-to-noise ratio for T1-weighted was -4.63 +/- 1.7; STIR, 10.8 +/- .98; FSE, 4.16 +/- .76; fat-saturated FSE, 4.87 +/- .19; and IRFSE, 5.2 +/- .87. STIR and IRFSE showed the highest number of lesions, followed by T1-weighted, fat-saturated FSE, and FSE sequences. T1-weighted sequences showed 94%, FSE 55%, and fat-saturated FSE 78% of the lesions detected. Epidural metastatic lesions were better depicted on T1-weighted, FSE, and fat-saturated FSE sequences. CONCLUSION: STIR was superior to both T1-weighted and FSE (with and without fat saturation) for detection of metastatic lesions, in terms of both percent contrast and contrast-to-noise ratio and visibility. IRFSE was equal to STIR for the detection of metastasis by both subjective and objective criteria. T1-weighted, FSE, and fat-saturated FSE sequences were superior to STIR and IRFSE in the detection of epidural metastatic disease. IRFSE provided faster scanning time, which could be translated into greater resolution.
This article has been cited by other articles:
![]() |
D. C. Zajick Jr, W. B. Morrison, M. E. Schweitzer, J. A. Parellada, and J. A. Carrino Benign and Malignant Processes: Normal Values and Differentiation with Chemical Shift MR Imaging in Vertebral Marrow Radiology, November 1, 2005; 237(2): 590 - 596. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Metser, H. Lerman, A. Blank, G. Lievshitz, F. Bokstein, and E. Even-Sapir Malignant Involvement of the Spine: Assessment by 18F-FDG PET/CT J. Nucl. Med., February 1, 2004; 45(2): 279 - 284. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. H. Bilsky, E. Lis, J. Raizer, H. Lee, and P. Boland The Diagnosis and Treatment of Metastatic Spinal Tumor Oncologist, December 1, 1999; 4(6): 459 - 469. [Abstract] [Full Text] |
||||
![]() |
J. S. Ross Newer Sequences for Spinal MR Imaging: Smorgasbord or Succotash of Acronyms? AJNR Am. J. Neuroradiol., March 1, 1999; 20(3): 361 - 373. [Full Text] |
||||



