AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bhadelia, R. A.
Right arrow Articles by Wolpert, S. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bhadelia, R. A.
Right arrow Articles by Wolpert, S. M.

American Journal of Neuroradiology, Vol 16, Issue 2 389-400, Copyright © 1995 by American Society of Neuroradiology


ARTICLES

Analysis of cerebrospinal fluid flow waveforms with gated phase- contrast MR velocity measurements

RA Bhadelia, AR Bogdan and SM Wolpert
Department of Radiology, New England Medical Center Hospitals, Boston, Mass 02111, USA.

PURPOSE: To analyze the characteristics of normal cerebrospinal fluid (CSF) flow waveforms and to relate them to the arterial input and venous output flow waveforms in healthy volunteers. METHODS: Cine phase- contrast MR was obtained in 17 volunteers. The temporal velocity information from the cervical pericord CSF spaces, basal cisterns, and aqueduct, as well as the internal carotid and vertebral arteries and internal jugular veins, were plotted as waveforms. The waveforms were analyzed for configurations, amplitudes, and temporal patterns. In four volunteers the reproducibility of the precord CSF flow waveforms was examined on different days. In three volunteers the effect of jugular venous compression on the precord and aqueductal CSF flow waveforms was also evaluated. RESULTS: (a) Distinct and reproducible configurational features were observed in the CSF flow waveforms. Jugular venous compression produced elevation of the disatolic slope of the precord waveforms. (b) The amplitudes were variable. Jugular venous compression reduced the precord CSF velocities. (c) The systolic temporal parameters were less variable and more reproducible than the diastolic temporal parameters. Jugular venous compression resulted in delay in the systolic parameters of the precord waveforms. (d) Craniocaudal and caudocranial postcord CSF flow occurred either simultaneous with or earlier than the precord CSF flow. Pericord CSF flow in either direction preceded that in the cisterns and in the aqueduct. (e) A significant temporal relationship was noted in the precord space between the time of the R wave to the maximum velocities and the arterial flow. CONCLUSION: CSF flow waveform analysis seems to be a reliable, reproducible, and sensitive method for assessing the CSF dynamics.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
D. Reubelt, L.C. Small, M.H.K. Hoffmann, T. Kapapa, and B.L. Schmitz
MR Imaging and Quantification of the Movement of the Lamina Terminalis Depending on the CSF Dynamics
AJNR Am. J. Neuroradiol., January 1, 2009; 30(1): 199 - 202.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
V. B. Joseph, L. Raghuram, I. P. Korah, and A. G. Chacko
MR Ventriculography for the Study of CSF Flow
AJNR Am. J. Neuroradiol., March 1, 2003; 24(3): 373 - 381.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
P. Brugieres, I. Idy-Peretti, C. Iffenecker, F. Parker, O. Jolivet, M. Hurth, A. Gaston, and J. Bittoun
CSF Flow Measurement in Syringomyelia
AJNR Am. J. Neuroradiol., November 1, 2000; 21(10): 1785 - 1792.
[Abstract] [Full Text] [PDF]