AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Clunie, D. A.
Right arrow Articles by Szumowski, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Clunie, D. A.
Right arrow Articles by Szumowski, J.

American Journal of Neuroradiology, Vol 16, Issue 7 1435-1440, Copyright © 1995 by American Society of Neuroradiology


ARTICLES

Detection of discrete white matter lesions after irreversible compression of MR images

DA Clunie, PJ Mitchell, J Howieson, S Roman-Goldstein and J Szumowski
Department of Diagnostic Imaging, King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia.

PURPOSE: To validate the use of techniques of irreversible compression of images, which can be performed using a block-based discrete cosine transform technique as defined by the Joint Photographic Experts Group, before they can be used in clinical applications, by evaluating the effect of compression on the ability of observers to detect discrete white matter lesions on MR images of the brain. METHODS: Sixty T2- and intermediate-weighted spin-echo images were compressed with varying degrees of coefficient quantization with compression ratios from 1:1 to more than 40:1, randomized, and evaluated by three observers blinded to the degree of compression. RESULTS: No significant difference in the number of lesions detected was apparent until compression ratios reached 40:1, despite a significant subjective loss in perceived image quality at 20:1. Only small (< or = 5 mm) lesions were missed at the highest degree of compression. No significant differences were observed in the detection of confluent periventricular white matter disease at any degree of compression tested. CONCLUSIONS: The use of high degrees of irreversible compression of MR images may be acceptable for diagnostic tasks.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
V. Bajpai, K. H. Lee, B. Kim, K. J. Kim, T. J. Kim, Y. H. Kim, and H. S. Kang
Differences in Compression Artifacts on Thin- and Thick-Section Lung CT Images
Am. J. Roentgenol., August 1, 2008; 191(2): W38 - W43.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. Kim, K. H. Lee, K. J. Kim, R. Mantiuk, H.-r. Kim, and Y. H. Kim
Artifacts in Slab Average-Intensity-Projection Images Reformatted from JPEG 2000 Compressed Thin-Section Abdominal CT Data Sets
Am. J. Roentgenol., June 1, 2008; 190(6): W342 - W350.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Kalyanpur, V. P. Neklesa, C. R. Taylor, A. R. Daftary, and J. A. Brink
Evaluation of JPEG and Wavelet Compression of Body CT Images for Direct Digital Teleradiologic Transmission
Radiology, December 1, 2000; 217(3): 772 - 779.
[Abstract] [Full Text]