AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hughes, S. R.
Right arrow Articles by Rappe, A. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hughes, S. R.
Right arrow Articles by Rappe, A. H.

American Journal of Neuroradiology, Vol 17, Issue 4 685-691, Copyright © 1996 by American Society of Neuroradiology


ARTICLES

The effect of flow arrest on distal embolic events during arterial occlusion with detachable coils: a canine study

SR Hughes, VB Graves, PP Kesava and AH Rappe
Department of Radiology, Memorial Medical Center, Springfield, ILL, USA.

PURPOSE: To determine the effect of proximal flow arrest on the frequency and timing of distal embolic events during occlusion of the common femoral artery with detachable coils. METHODS: Twenty-three complex fibered platinum coils were delivered into 10 common femoral arteries without proximal flow arrest. The arteries were continuously monitored for flow and embolic events by Doppler sonography during delivery and for at least 10 minutes after delivery of each coil. Thirty-four coils were delivered into 6 arteries after proximal flow arrest by inflation of a nondetachable balloon. After balloon deflation, each artery was monitored by Doppler sonography for 10 minutes. RESULTS: In the 10 arteries occluded without flow arrest, 87 events (8.7 per artery) occurred, of which 47 were embolic and 40 were indeterminate. In the 6 arteries with flow arrest, the number of emboli detected was 3 (0.5 per artery). Embolic events occurred only if there was residual flow. In those arteries that were occluded when the flow- arrest balloon was deflated, no emboli were detected. CONCLUSIONS: Proximal flow arrest virtually eliminates the risk of distal emboli during arterial occlusion with detachable fibered coils. The use of fibered coils, in conjunction with proximal flow arrest, allows for safe arterial occlusion when detachable balloons are not available or their use is not feasible.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
J. D. Barr and T. J. Lemley
Endovascular Arterial Occlusion Accomplished Using Microcoils Deployed with and without Proximal Flow Arrest: Results in 19 Patients
AJNR Am. J. Neuroradiol., September 1, 1999; 20(8): 1452 - 1456.
[Abstract] [Full Text]