AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tu, R. K.
Right arrow Articles by Winn, H. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tu, R. K.
Right arrow Articles by Winn, H. R.

American Journal of Neuroradiology, Vol 17, Issue 6 1127-1136, Copyright © 1996 by American Society of Neuroradiology


ARTICLES

Digital subtraction rotational angiography for aneurysms of the intracranial anterior circulation: injection method and optimization

RK Tu, WA Cohen, KR Maravilla, WH Bush, NH Patel, J Eskridge and HR Winn
Department of Radiology, University of Washington Medical Center, Seattle 98195, USA.

PURPOSE: To optimize parameters of rotational angiography for examination of the internal carotid circulation; to compare rotational angiography with standard digital subtraction angiography (DSA) in the evaluation of aneurysms of the intracranial internal carotid circulation; and to determine tolerance and safety limits of prolonged internal carotid injection angiography. METHODS: Rotational angiograms were obtained during injection of the internal carotid circulation as part of the clinical angiographic evaluation of aneurysms in 41 patients. Injection rates, X-ray delays, and fields of view were studied retrospectively. Findings at rotational angiography and standard DSA were compared. Nonionic contrast material was injected over 6 seconds, and patients were studied before and after prolonged injection angiography by physical and laboratory examination, including measurement of blood pressure, pulse, and intracranial pressure. RESULTS: Vascular conspicuity was equivalent at carotid injection rates of 4 and 5 mL/s delivered over 6 seconds. At 3 mL/s, more image manipulation was required to see small vascular structures. One-second X-ray delay combined with 6-second injection duration provided the best arterial depiction of intracranial vessels from start to end of rotational angiography. Maximal rotational resolution was with a 17-cm field of view. Identification of aneurysms and small vessels was equivalent at all injection rates. Aneurysm detection was equivalent with rotational angiography and DSA. In 9 of 31 aneurysms, the neck was defined more clearly with rotational angiography than with DSA, compared with 2 of 31 that were seen better with DSA. Aneurysms of the intracranial internal carotid circulation were seen with rotational angiography and not DSA in 12 of 41 cases. No change was noted in clinical or laboratory findings. CONCLUSION: Rotational angiography provided better definition of the aneurysmal neck and greater clarity of aneurysms than did DSA; it also improved the level of confidence in predicting the presence or absence of aneurysms, especially in the anterior communicating artery; however, in our small series it did not significantly increase the detection of aneurysms. Prolonged injection angiography was well tolerated in all patients.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
A.M. McKinney, C.S. Palmer, C.L. Truwit, A. Karagulle, and M. Teksam
Detection of Aneurysms by 64-Section Multidetector CT Angiography in Patients Acutely Suspected of Having an Intracranial Aneurysm and Comparison with Digital Subtraction and 3D Rotational Angiography
AJNR Am. J. Neuroradiol., March 1, 2008; 29(3): 594 - 602.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
S. Toyota, K. Iwaisako, H. Takimoto, and T. Yoshimine
Intravenous 3D Digital Subtraction Angiography in the Diagnosis of Unruptured Intracranial Aneurysms
AJNR Am. J. Neuroradiol., January 1, 2008; 29(1): 107 - 109.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
H.-S. Kang, M. H. Han, B. J. Kwon, O-K. Kwon, S. H. Kim, and K.-H. Chang
Evaluation of the Lenticulostriate Arteries with Rotational Angiography and 3D Reconstruction
AJNR Am. J. Neuroradiol., February 1, 2005; 26(2): 306 - 312.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
J V Byrne, C Colominas, J Hipwell, T Cox, J A Noble, G P Penney, and D J Hawkes
Assessment of a technique for 2D-3D registration of cerebral intra-arterial angiography
Br. J. Radiol., February 1, 2004; 77(914): 123 - 128.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
T. Hirai, Y. Korogi, K. Suginohara, K. Ono, T. Nishi, S. Uemura, M. Yamura, and Y. Yamashita
Clinical Usefulness of Unsubtracted 3D Digital Angiography Compared with Rotational Digital Angiography in the Pretreatment Evaluation of Intracranial Aneurysms
AJNR Am. J. Neuroradiol., June 1, 2003; 24(6): 1067 - 1074.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
U. U. Ernemann, E. Gronewaller, F. B. Duffner, O. Guervit, J. Claassen, and M. D. Skalej
Influence of Geometric and Hemodynamic Parameters on Aneurysm Visualization during Three-Dimensional Rotational Angiography: An in Vitro Study
AJNR Am. J. Neuroradiol., April 1, 2003; 24(4): 597 - 603.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A. Hochmuth, U. Spetzger, and M. Schumacher
Comparison of Three-Dimensional Rotational Angiography with Digital Subtraction Angiography in the Assessment of Ruptured Cerebral Aneurysms
AJNR Am. J. Neuroradiol., August 1, 2002; 23(7): 1199 - 1205.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Anxionnat, S. Bracard, X. Ducrocq, Y. Trousset, L. Launay, E. Kerrien, M. Braun, R. Vaillant, F. Scomazzoni, A. Lebedinsky, et al.
Intracranial Aneurysms: Clinical Value of 3D Digital Subtraction Angiography in the Therapeutic Decision and Endovascular Treatment
Radiology, March 1, 2001; 218(3): 799 - 808.
[Abstract] [Full Text]


Home page
Br. J. Radiol.Home page
H R Seymour, M B Matson, A-M Belli, R Morgan, J Kyriou, and U Patel
Rotational digital subtraction angiography of the renal arteries: technique and evaluation in the study of native and transplant renal arteries
Br. J. Radiol., February 1, 2001; 74(878): 134 - 141.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
J. B. Bederson, I. A. Awad, D. O. Wiebers, D. Piepgras, E. C. Haley Jr, T. Brott, G. Hademenos, D. Chyatte, R. Rosenwasser, and C. Caroselli
Recommendations for the Management of Patients With Unruptured Intracranial Aneurysms : A Statement for Healthcare Professionals From the Stroke Council of the American Heart Association
Stroke, November 1, 2000; 31(11): 2742 - 2750.
[Full Text] [PDF]


Home page
CirculationHome page
J. B. Bederson, I. A. Awad, D. O. Wiebers, D. Piepgras, E. C. Haley Jr, T. Brott, G. Hademenos, D. Chyatte, R. Rosenwasser, and C. Caroselli
Recommendations for the Management of Patients With Unruptured Intracranial Aneurysms : A Statement for Healthcare Professionals From the Stroke Council of the American Heart Association
Circulation, October 31, 2000; 102(18): 2300 - 2308.
[Full Text] [PDF]


Home page
RadiologyHome page
O. E. H. Elgersma, P. C. Buijs, A. F. J. Wüst, Y. van der Graaf, B. C. Eikelboom, and W. P. T. M. Mali
Maximum Internal Carotid Arterial Stenosis: Assessment with Rotational Angiography versus Conventional Intraarterial Digital Subtraction Angiography
Radiology, December 1, 1999; 213(3): 777 - 783.
[Abstract] [Full Text]