AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dahlen, R. T.
Right arrow Articles by Scalzo, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dahlen, R. T.
Right arrow Articles by Scalzo, D.

American Journal of Neuroradiology, Vol 18, Issue 1 67-75, Copyright © 1997 by American Society of Neuroradiology


ARTICLES

Overlapping thin-section fast spin-echo MR of the large vestibular aqueduct syndrome

RT Dahlen, HR Harnsberger, SD Gray, C Shelton, R Allen, JL Parkin and D Scalzo
Department of Radiology, University of Utah Health Sciences Center, Salt Lake City 84132, USA.

PURPOSE: To evaluate a high-resolution, thin-section fast spin-echo MR imaging technique of the inner ear to identify the large vestibular aqueduct syndrome seen on temporal bone CT scans. METHODS: We retrospectively reviewed the temporal bone CT scans of 21 patients with hearing loss and enlarged bony vestibular aqueducts by CT criteria. High-resolution fast spin-echo MR imaging was then performed on these patients using dual 3-inch phased-array receiver coils fixed in a temporomandibular joint holder and centered over the temporal bones. MR imaging included axial and oblique sagittal fast spin-echo sequences. The diameter of the midvestibular aqueduct on CT scans and the signal at the level of the midaqueduct on MR images were measured on axial sequences, then compared. High-resolution MR imaging with the same protocol was performed in 44 control subjects with normal ears, and similar measurements were taken. RESULTS: The average size of the enlarged bony vestibular aqueduct on CT scans was 3.7 mm, and the average width of the signal from within the enlarged aqueduct on MR images was 3.8 mm. Statistical analysis showed excellent correlation. MR images alone displayed the enlarged extraosseous endolymphatic sac, which accompanies the enlarged aqueduct in this syndrome. Five ears in three patients with enlarged bony vestibular aqueducts on CT scans showed no evidence of an enlarged endolymphatic duct or sac on MR images. An enlarged endolymphatic sac was seen on MR images in one patient with a bony vestibular aqueduct, which had normal measurements on CT scans. MR imaging alone identified a single case of mild cochlear dysplasia (Mondini malformation). In the 88 normal ears studied, the average size of the endolymphatic sac at its midpoint between the common crus and the external aperture measured on MR images was 0.8 mm (range, 0.5 to 1.4 mm). In 25% of the normal ears, no signal was seen from within the vestibular aqueduct. CONCLUSION: Thin-section, high- resolution fast spin-echo MR imaging of the inner ear is complementary to CT in studying patients with the large vestibular aqueduct syndrome, as MR imaging better displays the soft tissue and fluid of the membranous labyrinth.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
A.K. Morimoto, R.H. Wiggins III, P.A. Hudgins, G.L. Hedlund, B. Hamilton, S.K. Mukherji, S.A. Telian, and H.R. Harnsberger
Absent Semicircular Canals in CHARGE Syndrome: Radiologic Spectrum of Findings.
AJNR Am. J. Neuroradiol., September 1, 2006; 27(8): 1663 - 1671.
[Abstract] [Full Text] [PDF]


Home page
Arch Otolaryngol Head Neck SurgHome page
Radiology Quiz Case 1--Diagnosis
Arch Otolaryngol Head Neck Surg, June 1, 2005; 131(6): 536 - 537.
[Full Text] [PDF]


Home page
Arch Otolaryngol Head Neck SurgHome page
E. M. Arjmand and A. Webber
Audiometric Findings in Children With a Large Vestibular Aqueduct
Arch Otolaryngol Head Neck Surg, October 1, 2004; 130(10): 1169 - 1174.
[Abstract] [Full Text] [PDF]


Home page
Arch Otolaryngol Head Neck SurgHome page
R. Klingebiel, N. Thieme, D. Kivelitz, C. Enzweiler, M. Werbs, and R. Lehmann
Three-dimensional Imaging of the Inner Ear by Volume-Rendered Reconstructions of Magnetic Resonance Data
Arch Otolaryngol Head Neck Surg, May 1, 2002; 128(5): 549 - 553.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
S. Naganawa, T. Koshikawa, E. Iwayama, H. Fukatsu, T. Ishiguchi, T. Ishigaki, M. Ikeda, T. Nakashima, and N. Ichinose
MR Imaging of the Enlarged Endolymphatic Duct and Sac Syndrome by Use of a 3D Fast Asymmetric Spin-echo Sequence: Volume and Signal-intensity Measurement of the Endolymphatic Duct and Sac and Area Measurement of the Cochlear Modiolus
AJNR Am. J. Neuroradiol., October 1, 2000; 21(9): 1664 - 1669.
[Abstract] [Full Text]


Home page
RadiologyHome page
S. Naganawa, T. Ito, E. Iwayama, H. Fukatsu, T. Ishigaki, T. Nakashima, and N. Ichinose
MR Imaging of the Cochlear Modiolus: Area Measurement in Healthy Subjects and in Patients with a Large Endolymphatic Duct and Sac
Radiology, December 1, 1999; 213(3): 819 - 823.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
H. C. Davidson, H. R. Harnsberger, M. M. Lemmerling, A. A. Mancuso, D. K. White, K. A. Tong, R. T. Dahlen, and C. Shelton
MR Evaluation of Vestibulocochlear Anomalies Associated with Large Endolymphatic Duct and Sac
AJNR Am. J. Neuroradiol., September 1, 1999; 20(8): 1435 - 1441.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
P. Hans, A. J. Grant, R. D. Laitt, R. T. Ramsden, A. Kassner, and A. Jackson
Comparison of Three-Dimensional Visualization Techniques for Depicting the Scala Vestibuli and Scala Tympani of the Cochlea by Using High-Resolution MR Imaging
AJNR Am. J. Neuroradiol., August 1, 1999; 20(7): 1197 - 1206.
[Abstract] [Full Text]