American Journal of Neuroradiology, Vol 18, Issue 3 409-415, Copyright © 1997 by American Society of Neuroradiology
ARTICLES |
Accuracy and precision of CT angiography in a model of carotid artery bifurcation stenosis
JE Dix, AJ Evans, DF Kallmes, AH Sobel and CD Phillips
Department of Radiology, University of Virginia Health Sciences Center, Charlottesville, USA.
PURPOSE: To determine optimal acquisition parameters and measurement techniques for CT angiography of the carotid bifurcation. METHODS: Anatomic phantoms were created in which the diameter of the carotid artery stenoses ranged from 15% to 95%. Initially, we compared the accuracy of stenosis determination obtained by using various values of section collimation and table pitch. Subsequently, applying the combination of collimation and pitch that yielded the greatest longitudinal coverage without degradation in accuracy, we compared the accuracy of measurements performed with various display algorithms, including axial, magnified axial, maximum intensity projection (MIP), and shaded surface display (SSD) images. Last, we determined the effect on accuracy of varying both window and level settings. The standard of reference for all measurements was considered to be caliper measurements made of the models at the time of their construction. RESULTS: CT angiography was highly accurate for determining the percentage of stenosis; the average difference between CT angiographic measurements and the standard of reference was less than 1% for all parameter combinations and measurement techniques. Precision varied among the measurement techniques. Magnified axial images provided more precise measurements than either the MIP or SSD images. Although there was a trend toward improved precision with the use of magnified versus unmagnified axial images and MIP versus SSD images, neither of these comparisons reached statistical significance. Systematic error was produced by changing the level setting from that halfway between the luminal density and vessel wall density. Random error was introduced by using window settings greater than zero. CONCLUSION: CT angiography was highly accurate and precise for determining percentage of stenosis. The highest precision was attained by using magnified axial images with the level halfway between luminal density and vessel wall density and with the window set to zero.
This article has been cited by other articles:
![]() |
A. J. Fox, S. P. Symons, R. I. Aviv, P. Howard, R. Yeung, and E. S. Bartlett Should Modeling Methodology Suppress Anatomic Excellence? Stroke, November 1, 2009; 40(11): 3411 - 3412. [Full Text] [PDF] |
||||
![]() |
M. R Jaff, G. V Goldmakher, M. H Lev, and J. M Romero Imaging of the carotid arteries: the role of duplex ultrasonography, magnetic resonance arteriography, and computerized tomographic arteriography Vascular Medicine, November 1, 2008; 13(4): 281 - 292. [Abstract] [PDF] |
||||
![]() |
T. G. Vrachliotis, K. G. Bis, A. Haidary, R. Kosuri, M. Balasubramaniam, M. Gallagher, G. Raff, M. Ross, B. O'Neil, and W. O'Neill Atypical Chest Pain: Coronary, Aortic, and Pulmonary Vasculature Enhancement at Biphasic Single-Injection 64-Section CT Angiography Radiology, May 1, 2007; 243(2): 368 - 376. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. S. Bartlett, T. D. Walters, S. P. Symons, and A. J. Fox Carotid Stenosis Index Revisited With Direct CT Angiography Measurement of Carotid Arteries to Quantify Carotid Stenosis Stroke, February 1, 2007; 38(2): 286 - 291. [Abstract] [Full Text] [PDF] |
||||
![]() |
E.S. Bartlett, T.D. Walters, S.P. Symons, and A.J. Fox Diagnosing Carotid Stenosis Near-Occlusion by Using CT Angiography AJNR Am. J. Neuroradiol., March 1, 2006; 27(3): 632 - 637. [Abstract] [Full Text] [PDF] |
||||
![]() |
E.S. Bartlett, S.P. Symons, and A.J. Fox Correlation of Carotid Stenosis Diameter and Cross-Sectional Areas with CT Angiography AJNR Am. J. Neuroradiol., March 1, 2006; 27(3): 638 - 642. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. R. Nandalur, E. Baskurt, K. D. Hagspiel, M. Finch, C. D. Phillips, S. R. Bollampally, and C. M. Kramer Carotid Artery Calcification on CT May Independently Predict Stroke Risk Am. J. Roentgenol., February 1, 2006; 186(2): 547 - 552. [Abstract] [Full Text] [PDF] |
||||
![]() |
E.S. Bartlett, T.D. Walters, S.P. Symons, and A.J. Fox Quantification of Carotid Stenosis on CT Angiography AJNR Am. J. Neuroradiol., January 1, 2006; 27(1): 13 - 19. [Abstract] [Full Text] [PDF] |
||||
![]() |
B.B. Ertl-Wagner, R. Bruening, J. Blume, R.-T. Hoffmann, S. Mueller-Schunk, B. Snyder, and M.F. Reiser Relative Value of Sliding-Thin-Slab Multiplanar Reformations and Sliding-Thin-Slab Maximum Intensity Projections as Reformatting Techniques in Multisection CT Angiography of the Cervicocranial Vessels AJNR Am. J. Neuroradiol., January 1, 2006; 27(1): 107 - 113. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Suzuki, S. Furui, and T. Kaminaga Accuracy of Automated CT Angiography Measurement of Vascular Diameter in Phantoms: Effect of Size of Display Field of View, Density of Contrast Medium, and Wall Thickness Am. J. Roentgenol., June 1, 2005; 184(6): 1940 - 1944. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y.-H. Kim, E. M. Marom, J. E. Herndon II, and H. P. McAdams Pulmonary Vein Diameter, Cross-sectional Area, and Shape: CT Analysis Radiology, April 1, 2005; 235(1): 43 - 49. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. R. Nandalur, E. Baskurt, K. D. Hagspiel, C. D. Phillips, and C. M. Kramer Calcified Carotid Atherosclerotic Plaque Is Associated Less with Ischemic Symptoms Than Is Noncalcified Plaque on MDCT Am. J. Roentgenol., January 1, 2005; 184(1): 295 - 298. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Suzuki, S. Furui, T. Kaminaga, and T. Yamauchi Measurement of Vascular Diameter In Vitro by Automated Software for CT Angiography: Effects of Inner Diameter, Density of Contrast Medium, and Convolution Kernel Am. J. Roentgenol., May 1, 2004; 182(5): 1313 - 1317. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. H. Lev, J. M. Romero, D. N.F. Goodman, R. Bagga, H. Y. K. Kim, N. A. Clerk, R. H. Ackerman, and R. G. Gonzalez Total Occlusion versus Hairline Residual Lumen of the Internal Carotid Arteries: Accuracy of Single Section Helical CT Angiography AJNR Am. J. Neuroradiol., June 1, 2003; 24(6): 1123 - 1129. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. A. Addis, K. D. Hopper, T. A. Iyriboz, Y. Liu, S. W. Wise, C. J. Kasales, J. S. Blebea, and D. T. Mauger CT Angiography: In Vitro Comparison of Five Reconstruction Methods Am. J. Roentgenol., November 1, 2001; 177(5): 1171 - 1176. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Porsche, L. Walker, D. Mendelow, and D. Birchall Evaluation of Cross-Sectional Luminal Morphology in Carotid Atherosclerotic Disease by Use of Spiral CT Angiography Stroke, November 1, 2001; 32(11): 2511 - 2515. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Liu, K. D. Hopper, D. T. Mauger, and K. A. Addis CT Angiographic Measurement of the Carotid Artery: Optimizing Visualization by Manipulating Window and Level Settings and Contrast Material Attenuation Radiology, November 1, 2000; 217(2): 494 - 500. [Abstract] [Full Text] |
||||
![]() |
R. I. Grossman BRAIN IMAGING AJNR Am. J. Neuroradiol., January 1, 2000; 21(1): 9 - 18. [Full Text] [PDF] |
||||
![]() |
M. H. Lev, J. Farkas, J. J. Gemmete, S. T. Hossain, G. J. Hunter, W. J. Koroshetz, and R. G. Gonzalez Acute Stroke: Improved Nonenhanced CT Detection-Benefits of Soft-Copy Interpretation by Using Variable Window Width and Center Level Settings Radiology, October 1, 1999; 213(1): 150 - 155. [Abstract] [Full Text] |
||||
![]() |
X. Leclerc, O. Godefroy, C. Lucas, J.-F. Benhaim, T. S. Michel, D. Leys, and J. P. Pruvo Internal Carotid Arterial Stenosis: CT Angiography with Volume Rendering Radiology, March 1, 1999; 210(3): 673 - 682. [Abstract] [Full Text] |
||||
![]() |
T. Hirai, Y. Korogi, K. Ono, Y. Murata, M. Takahashi, K. Suginohara, and S. Uemura Maximum Stenosis of Extracranial Internal Carotid Artery: Effect of Luminal Morphology on Stenosis Measurement by Using CT Angiography and Conventional DSA Radiology, December 1, 2001; 221(3): 802 - 809. [Abstract] [Full Text] [PDF] |
||||




