Endovascular extraction of malpositioned fibered platinum microcoils from the aneurysm sac during endovascular therapy
GH Zoarski, HM Bear, JC Clouston and J Ragheb
Department of Radiology, University of Maryland Medical Center, Baltimore 21201, USA.
We describe two cases of coil malpositioning that occurred during endovascular occlusion of saccular basilar tip aneurysms with fibered platinum microcoils. The technique of endovascular coil extraction, accomplished successfully and without complication in both cases, is described and may be applicable to recently available controlled- detachment coil systems.