AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yousry, T. A.
Right arrow Articles by Voltz, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yousry, T. A.
Right arrow Articles by Voltz, R.

American Journal of Neuroradiology, Vol 18, Issue 5 959-963, Copyright © 1997 by American Society of Neuroradiology


ARTICLES

Comparison of MR pulse sequences in the detection of multiple sclerosis lesions

TA Yousry, M Filippi, C Becker, MA Horsfield and R Voltz
Department of Neuroradiology, Klinikum Grosshadern, Ludwig-Maximilian University, Munich, Germany.

PURPOSE: To compare the sensitivity of conventional spin-echo, fast spin-echo, fast fluid-attenuated inversion recovery (FLAIR), and turbo gradient spin-echo MR sequences in the detection of multiple sclerosis lesions. METHODS: Conventional spin-echo, fast spin-echo, fast FLAIR, and turbo gradient spin-echo sequences were performed on a 1.0-T MR imager in seven patients with clinically definite multiple sclerosis. The images in each sequence were evaluated by two raters and consensus was reached by agreement. RESULTS: In comparing conventional spin-echo with fast spin-echo sequences, five lesions were seen only by conventional spin-echo and 63 were seen only by fast spin-echo; in comparing conventional spin-echo with fast FLAIR sequences, 18 lesions were seen only by conventional spin-echo and 109 only by fast FLAIR; in comparing conventional spin-echo with turbo gradient spin-echo sequences, 51 lesions were seen only by conventional spin-echo and seven only by turbo gradient spin-echo; in comparing fast spin-echo with fast FLAIR sequences, 45 lesions were seen only by fast spin-echo and 52 only by fast FLAIR. CONCLUSION: Fast spin-echo and fast FLAIR sequences improve the sensitivity of MR imaging in the detection of multiple sclerosis lesions with reduced acquisition time as compared with conventional spin-echo sequences. These sequences should therefore be considered for serial studies in patients with multiple sclerosis. The sensitivity of turbo gradient spin-echo was inferior to the other sequences, but its reduced acquisition time could make this technique the ideal choice for patients who cannot tolerate longer examination times.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
M.P. Wattjes, G.G. Lutterbey, J. Gieseke, F. Traber, L. Klotz, S. Schmidt, and H.H. Schild
Double Inversion Recovery Brain Imaging at 3T: Diagnostic Value in the Detection of Multiple Sclerosis Lesions
AJNR Am. J. Neuroradiol., January 1, 2007; 28(1): 54 - 59.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. H. Woo, L. P. Henry, J. Krejza, and E. R. Melhem
Detection of Simulated Multiple Sclerosis Lesions on T2-weighted and FLAIR Images of the Brain: Observer Performance
Radiology, October 1, 2006; 241(1): 206 - 212.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. Pikus, J. H. Woo, R. L. Wolf, E. H. Herskovits, G. Moonis, A. F. Jawad, J. Krejza, and E. R. Melhem
Artificial Multiple Sclerosis Lesions on Simulated FLAIR Brain MR Images: Echo Time and Observer Performance in Detection
Radiology, April 1, 2006; 239(1): 238 - 245.
[Abstract] [Full Text] [PDF]


Home page
NeurologyHome page
P. Sostak, C.S. Padovan, T.A. Yousry, G. Ledderose, H.-J. Kolb, and A. Straube
Prospective evaluation of neurological complications after allogeneic bone marrow transplantation
Neurology, March 11, 2003; 60(5): 842 - 848.
[Abstract] [Full Text] [PDF]


Home page
Arch NeurolHome page
R. Bakshi, S. Ariyaratana, R. H. B. Benedict, and L. Jacobs
Fluid-Attenuated Inversion Recovery Magnetic Resonance Imaging Detects Cortical and Juxtacortical Multiple Sclerosis Lesions
Arch Neurol, May 1, 2001; 58(5): 742 - 748.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E. H. Herskovits, R. Itoh, and E. R. Melhem
Accuracy for Detection of Simulated Lesions: Comparison of Fluid-Attenuated Inversion-Recovery, Proton Density-Weighted, and T2-Weighted Synthetic Brain MR Imaging
Am. J. Roentgenol., May 1, 2001; 176(5): 1313 - 1318.
[Abstract] [Full Text] [PDF]


Home page
Mult SclerHome page
R H. Lazeron, D W Langdon, M Filippi, J H. van Waesberghe, V L Stevenson, J B. Boringa, D Origgi, A J Thompson, M Falautano, C. Polman, et al.
Neuropsychological impairment in multiple sclerosis patients: the role of (juxta)cortical lesion on FLAIR
Multiple Sclerosis, August 1, 2000; 6(4): 280 - 285.
[Abstract] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Tintoré, A. Rovira, M. J. Martínez, J. Rio, P. Díaz-Villoslada, L. Brieva, C. Borrás, E. Grivé, J. Capellades, and X. Montalban
Isolated Demyelinating Syndromes: Comparison of Different MR Imaging Criteria to Predict Conversion to Clinically Definite Multiple Sclerosis
AJNR Am. J. Neuroradiol., April 1, 2000; 21(4): 702 - 706.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
M. Filippi, M. A. Rocca, M. Wiessmann, S. Mennea, M. Cercignani, T. A. Yousry, M. P. Sormani, and G. Comi
A Comparison of MR Imaging with Fast-FLAIR, HASTE-FLAIR, and EPI-FLAIR Sequences in the Assessment of Patients with Multiple Sclerosis
AJNR Am. J. Neuroradiol., November 1, 1999; 20(10): 1931 - 1938.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
D. M. Moriarty, A. J. Blackshaw, P. R. Talbot, H. L. Griffiths, J. S. Snowden, V. F. Hillier, S. Capener, R. D. Laitt, and A. Jackson
Memory Dysfunction in Multiple Sclerosis Corresponds to Juxtacortical Lesion Load on Fast Fluid-Attenuated Inversion-Recovery MR Images
AJNR Am. J. Neuroradiol., November 1, 1999; 20(10): 1956 - 1962.
[Abstract] [Full Text]


Home page
RadiologyHome page
T. Okuda, Y. Korogi, Y. Shigematsu, T. Sugahara, T. Hirai, I. Ikushima, L. Liang, and M. Takahashi
Brain Lesions: When Should Fluid-attenuated Inversion-Recovery Sequences Be Used in MR Evaluation?
Radiology, September 1, 1999; 212(3): 793 - 798.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
G. Mastronardo, M. A. Rocca, G. Iannucci, C. Pereira, and M. Filippi
A Longitudinal MR Study of the Presymptomatic Phase in a Patient with Clinically Definite Multiple Sclerosis
AJNR Am. J. Neuroradiol., August 1, 1999; 20(7): 1268 - 1272.
[Abstract] [Full Text]


Home page
BrainHome page
M. A. Lee, S. Smith, J. Palace, S. Narayanan, N. Silver, L. Minicucci, M. Filippi, D. H. Miller, D. L. Arnold, and P. M. Matthews
Spatial mapping of T2 and gadolinium-enhancing T1 lesion volumes in multiple sclerosis: evidence for distinct mechanisms of lesion genesis?
Brain, July 1, 1999; 122(7): 1261 - 1270.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
Rovaris, Comi, M. Rocca, Cercignani, Colombo, Santuccio, and Filippi
Relevance of Hypointense Lesions on Fast Fluid-Attenuated Inversion Recovery MR Images as a Marker of Disease Severity in Cases of Multiple
AJNR Am. J. Neuroradiol., May 1, 1999; 20(5): 813 - 820.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
T. A. Yousry, K. Seelos, M. Mayer, R. Brüning, I. Uttner, M. Dichgans, S. Mammi, A. Straube, N. Mai, and M. Filippi
Characteristic MR Lesion Pattern and Correlation of T1 and T2 Lesion Volume with Neurologic and Neuropsychological Findings in Cerebral Autosomal Dominant Arteriopathy with Subcortical Infarcts and Leukoencephalopathy (CADASIL)
AJNR Am. J. Neuroradiol., January 1, 1999; 20(1): 91 - 100.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
M. Filippi, M. A. Rocca, C. Gasperini, M. P. Sormani, S. Bastianello, M. A. Horsfield, C. Pozzilli, and G. Comi
Interscanner Variation in Brain MR Lesion Load Measurements in Multiple Sclerosis Using Conventional Spin-Echo, Rapid Relaxation-Enhanced, and Fast-FLAIR Sequences
AJNR Am. J. Neuroradiol., January 1, 1999; 20(1): 133 - 137.
[Abstract] [Full Text]