American Journal of Neuroradiology, Vol 18, Issue 6 1035-1039, Copyright © 1997 by American Society of Neuroradiology
ARTICLES |
The low sensitivity of fluid-attenuated inversion-recovery MR in the detection of multiple sclerosis of the spinal cord
MD Keiper, RI Grossman, JC Brunson and MD Schnall
Department Radiology, Hospital of the University of Pennsylvania, Philadelphia 19104, USA.
PURPOSE: To confirm the expected superiority of fluid-attenuated inversion-recovery (FLAIR) over conventional fast spin-echo MR imaging in the detection of multiple sclerosis (MS) of the spinal cord. METHODS: Fifteen subjects with known MS involving the spinal cord and brain were studied prospectively. The entire cord was imaged with a phased-array coil on a 1.5-T MR system. Sagittal T1-weighted and fast spin-echo proton density- and T2-weighted images were followed by fast FLAIR images. FLAIR parameters were varied to optimize lesion conspicuity with optimal inversion times (TIs) ranging from 2400 to 2600. Lesion conspicuity and detection were compared between the fast spin-echo and FLAIR images by three radiologists who reached agreement by consensus. RESULTS: The FLAIR technique effectively suppressed cerebrospinal fluid (CSF) signal and reduced CSF pulsation and truncation artifacts in all cases. Shorter imaging parameters (repetition time of 4000 to 6000, TI of 1500 to 2000) uniformly decreased lesion conspicuity in all subjects. Of 11 cord lesions in five subjects imaged with the longer parameters (repetition time of 8000 to 11,000, TI of 2400 to 2600), three were not seen on FLAIR images, four were less conspicuous on FLAIR images, and four were seen equally or better on FLAIR images. CONCLUSION: Although successful in suppressing CSF signal and reducing imaging artifacts, fast FLAIR imaging appears unreliable in the detection of MS lesions in the spinal cord.
This article has been cited by other articles:
![]() |
Y. Ge Multiple Sclerosis: The Role of MR Imaging AJNR Am. J. Neuroradiol., June 1, 2006; 27(6): 1165 - 1176. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Bastos Leite, E. C.W. van Straaten, P. Scheltens, G. Lycklama, and F. Barkhof Thalamic Lesions in Vascular Dementia: Low Sensitivity of Fluid-Attenuated Inversion Recovery (FLAIR) Imaging Stroke, February 1, 2004; 35(2): 415 - 419. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Filippi, M. A. Rocca, M. Wiessmann, S. Mennea, M. Cercignani, T. A. Yousry, M. P. Sormani, and G. Comi A Comparison of MR Imaging with Fast-FLAIR, HASTE-FLAIR, and EPI-FLAIR Sequences in the Assessment of Patients with Multiple Sclerosis AJNR Am. J. Neuroradiol., November 1, 1999; 20(10): 1931 - 1938. [Abstract] [Full Text] |
||||
![]() |
D. B. Hackney MR Studies of the Spinal Cord in Patients with Multiple Sclerosis: What Should We Do? AJNR Am. J. Neuroradiol., October 1, 1999; 20(9): 1581 - 1583. [Full Text] |
||||
![]() |
M. A. Rocca, G. Mastronardo, M. A. Horsfield, C. Pereira, G. Iannucci, B. Colombo, L. Moiola, G. Comi, and M. Filippi Comparison of Three MR Sequences for the Detection of Cervical Cord Lesions in Patients with Multiple Sclerosis AJNR Am. J. Neuroradiol., October 1, 1999; 20(9): 1710 - 1716. [Abstract] [Full Text] |
||||
![]() |
T. Okuda, Y. Korogi, Y. Shigematsu, T. Sugahara, T. Hirai, I. Ikushima, L. Liang, and M. Takahashi Brain Lesions: When Should Fluid-attenuated Inversion-Recovery Sequences Be Used in MR Evaluation? Radiology, September 1, 1999; 212(3): 793 - 798. [Abstract] [Full Text] |
||||
![]() |
J. S. Ross Newer Sequences for Spinal MR Imaging: Smorgasbord or Succotash of Acronyms? AJNR Am. J. Neuroradiol., March 1, 1999; 20(3): 361 - 373. [Full Text] |
||||