AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kallmes, D. F.
Right arrow Articles by Dion, J. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kallmes, D. F.
Right arrow Articles by Dion, J. E.

American Journal of Neuroradiology, Vol 18, Issue 7 1243-1251, Copyright © 1997 by American Society of Neuroradiology


ARTICLES

Thrombogenicity of hydrophilic and nonhydrophilic microcatheters and guiding catheters [published erratum appears in AJNR Am J Neuroradiol 1997 Oct;18(9):1800]

DF Kallmes, JK McGraw, AJ Evans, JM Mathis, RW Hergenrother, ME Jensen, HJ Cloft, M Lopes and JE Dion
Department of Radiology, University of Virginia, Charlottesville 22908, USA.

PURPOSE: To assess in a swine model the in vivo thrombogenicity of various microcatheters and guiding catheters as a function of catheter material, catheter coating, and duration of implantation. METHODS: Microcatheters (Tracker 18 and Fastracker 18, Target Therapeutics, Fremont, Calif; Magic 1.8, Balt, Montmorency, France; and Transit, Cordis Endovascular Systems, Miami Lakes, Fla) were placed through 6F guiding catheters (Fasguide, Target Therapeutics, and Envoy, Cordis Endovascular Systems) into the common carotid arteries of swine for 30 minutes (short term), 90 minutes (medium term), and 35 days (long term). Guiding catheters were implanted for 5 hours. At the end of the implantation periods the catheters were retracted and fixed for scanning electron microscopy. RESULTS: The surface of the Fastracker microcatheter was devoid of debris after both short- and medium-term implantation. The Tracker microcatheter had minimal accumulation of cellular elements whereas the Transit microcatheter showed moderate accumulation of nondeformed red blood cells. Neither the Tracker nor the Transit microcatheter showed evidence of increasing debris accumulation after medium-term implantation as compared with short-term implantation. The Magic microcatheter was coated with gross thrombus after both short- and medium-term implantation. The Fasguide guiding catheter was nearly devoid of debris, while the Envoy guiding catheter had moderate thrombus formation. Long-term implantation of the Fastracker microcatheter was well tolerated whereas that of the Transit catheter resulted in vessel occlusion. CONCLUSIONS: Hydrophilic microcatheters and guiding catheters are less thrombogenic than their nonhydrophilic counterparts, but not all hydrophilic coatings are equally hypothrombogenic. Degree of thrombogenicity depends on catheter material rather than surface morphology. Medium-term implantation did not yield increasing thrombus formation relative to short-term implantation.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
C. M. Strother
INTERVENTIONAL NEURORADIOLOGY
AJNR Am. J. Neuroradiol., January 1, 2000; 21(1): 19 - 24.
[Full Text] [PDF]