AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fahrig, R.
Right arrow Articles by Holdsworth, D. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fahrig, R.
Right arrow Articles by Holdsworth, D. W.

American Journal of Neuroradiology, Vol 18, Issue 8 1507-1514, Copyright © 1997 by American Society of Neuroradiology


ARTICLES

Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results

R Fahrig, AJ Fox, S Lownie and DW Holdsworth
Department of Medical Biophysics, University of Western Ontario, London, Canada.

PURPOSE: To evaluate the potential use of a C-arm mounted X-ray image intensifier (XRII) system to generate three-dimensional computed rotational angiograms during interventional neuroradiologic procedures. METHODS: A clinical angiographic system was modified to allow collection of sufficient views during selective intraarterial contrast injections for CT reconstruction of a 15 x 15 x 15-cm3 volume. Image intensifier distortion and C-arm instabilities were corrected by using image-based techniques. The impact of the pulsatile nature of the vessels during image data acquisition and of the presence of bone on the 3-D reconstructions was investigated by generating 3-D reconstructions of an anesthetized 20-kg pig and of a human skull phantom. RESULTS: A sequence of images sufficient for 3-D reconstruction was acquired in less than 5 seconds. Image intensifier distortion and C-arm instabilities were corrected to subpixel accuracy (0.035 mm and 0.07 mm, respectively). Both the intracranial vessels of the pig and the small, high-contrast structures in the skull were reconstructed with negligible artifacts. CONCLUSIONS: Using a C-arm mounted XRII system, computed rotational angiography can provide true 3- D images of diagnostic quality.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
A.C. Miracle and S.K. Mukherji
Conebeam CT of the Head and Neck, Part 2: Clinical Applications
AJNR Am. J. Neuroradiol., August 1, 2009; 30(7): 1285 - 1292.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A.J. Fox, J. Millar, J. Raymond, J.C. Pryor, D. Roy, G.A. Tomlinson, J.P. McKay, and A.J. Molyneux
Dangerous Advances in Measurements from Digital Subtraction Angiography: When Is a Millimeter Not a Millimeter?
AJNR Am. J. Neuroradiol., March 1, 2009; 30(3): 459 - 461.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A.J. Fox, S.P. Symons, and R.I. Aviv
CT Angiography is State-of-the-Art First Vascular Imaging for Subarachnoid Hemorrhage
AJNR Am. J. Neuroradiol., June 1, 2008; 29(6): e41 - e42.
[Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
S. Kakeda, Y. Korogi, Y. Miyaguni, J. Moriya, N. Ohnari, N. Oda, K. Nishino, and W. Miyamoto
A Cone-Beam Volume CT Using a 3D Angiography System with a Flat Panel Detector of Direct Conversion Type: Usefulness for Superselective Intra-arterial Chemotherapy for Head and Neck Tumors
AJNR Am. J. Neuroradiol., October 1, 2007; 28(9): 1783 - 1788.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Piotin, B. Daghman, C. Mounayer, L. Spelle, and J. Moret
Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms.
AJNR Am. J. Neuroradiol., April 1, 2006; 27(4): 839 - 842.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A. Doerfler, I. Wanke, S.L. Goericke, H. Wiedemayer, T. Engelhorn, E.R. Gizewski, D. Stolke, and M. Forsting
Endovascular Treatment of Middle Cerebral Artery Aneurysms with Electrolytically Detachable Coils
AJNR Am. J. Neuroradiol., March 1, 2006; 27(3): 513 - 520.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
E.S. Bartlett, T.D. Walters, S.P. Symons, and A.J. Fox
Quantification of Carotid Stenosis on CT Angiography
AJNR Am. J. Neuroradiol., January 1, 2006; 27(1): 13 - 19.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. M. Racadio, B. L. Fricke, B. V. Jones, and L. F. Donnelly
Three-Dimensional Rotational Angiography of Neurovascular Lesions in Pediatric Patients
Am. J. Roentgenol., January 1, 2006; 186(1): 75 - 84.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
D. E. Hyde, A. J. Fox, I. Gulka, P. Kalapos, D. H. Lee, D. M. Pelz, and D. W. Holdsworth
Internal Carotid Artery Stenosis Measurement: Comparison of 3D Computed Rotational Angiography and Conventional Digital Subtraction Angiography
Stroke, December 1, 2004; 35(12): 2776 - 2781.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
D. A. Steinman, J. S. Milner, C. J. Norley, S. P. Lownie, and D. W. Holdsworth
Image-Based Computational Simulation of Flow Dynamics in a Giant Intracranial Aneurysm
AJNR Am. J. Neuroradiol., April 1, 2003; 24(4): 559 - 566.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
U. U. Ernemann, E. Gronewaller, F. B. Duffner, O. Guervit, J. Claassen, and M. D. Skalej
Influence of Geometric and Hemodynamic Parameters on Aneurysm Visualization during Three-Dimensional Rotational Angiography: An in Vitro Study
AJNR Am. J. Neuroradiol., April 1, 2003; 24(4): 597 - 603.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
T. Abe, M. Hirohata, N. Tanaka, Y. Uchiyama, K. Kojima, K. Fujimoto, A. M. Norbash, and N. Hayabuchi
Clinical Benefits of Rotational 3D Angiography in Endovascular Treatment of Ruptured Cerebral Aneurysm
AJNR Am. J. Neuroradiol., April 1, 2002; 23(4): 686 - 688.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. C. van den Berg, T. Th. C. Overtoom, J. C. de Valois, and F. L. Moll
Using Three-Dimensional Rotational Angiography for Sizing of Covered Stents
Am. J. Roentgenol., January 1, 2002; 178(1): 149 - 152.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Anxionnat, S. Bracard, X. Ducrocq, Y. Trousset, L. Launay, E. Kerrien, M. Braun, R. Vaillant, F. Scomazzoni, A. Lebedinsky, et al.
Intracranial Aneurysms: Clinical Value of 3D Digital Subtraction Angiography in the Therapeutic Decision and Endovascular Treatment
Radiology, March 1, 2001; 218(3): 799 - 808.
[Abstract] [Full Text]


Home page
Br. J. Radiol.Home page
H R Seymour, M B Matson, A-M Belli, R Morgan, J Kyriou, and U Patel
Rotational digital subtraction angiography of the renal arteries: technique and evaluation in the study of native and transplant renal arteries
Br. J. Radiol., February 1, 2001; 74(878): 134 - 141.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
E. I. Bluth, H. J. M. Barnett, M. Eliasziw, and H. Meldrum
Plaque Morphology as a Risk Factor for Stroke
JAMA, July 12, 2000; 284(2): 177 - 177.
[Full Text] [PDF]


Home page
RadiologyHome page
M. El-Sheik, J. T. Heverhagen, H. Alfke, J. J. Froelich, J. Hornegger, T. Brunner, K. J. Klose, and H.-J. Wagner
Multiplanar Reconstructions and Three-dimensional Imaging (Computed Rotational Osteography) of Complex Fractures by Using a C-arm System: Initial Results
Radiology, December 1, 2001; 221(3): 843 - 849.
[Abstract] [Full Text] [PDF]