American Journal of Neuroradiology, Vol 18, Issue 8 1507-1514, Copyright © 1997 by American Society of Neuroradiology
ARTICLES |
Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results
R Fahrig, AJ Fox, S Lownie and DW Holdsworth
Department of Medical Biophysics, University of Western Ontario, London, Canada.
PURPOSE: To evaluate the potential use of a C-arm mounted X-ray image intensifier (XRII) system to generate three-dimensional computed rotational angiograms during interventional neuroradiologic procedures. METHODS: A clinical angiographic system was modified to allow collection of sufficient views during selective intraarterial contrast injections for CT reconstruction of a 15 x 15 x 15-cm3 volume. Image intensifier distortion and C-arm instabilities were corrected by using image-based techniques. The impact of the pulsatile nature of the vessels during image data acquisition and of the presence of bone on the 3-D reconstructions was investigated by generating 3-D reconstructions of an anesthetized 20-kg pig and of a human skull phantom. RESULTS: A sequence of images sufficient for 3-D reconstruction was acquired in less than 5 seconds. Image intensifier distortion and C-arm instabilities were corrected to subpixel accuracy (0.035 mm and 0.07 mm, respectively). Both the intracranial vessels of the pig and the small, high-contrast structures in the skull were reconstructed with negligible artifacts. CONCLUSIONS: Using a C-arm mounted XRII system, computed rotational angiography can provide true 3- D images of diagnostic quality.
This article has been cited by other articles:
![]() |
A.C. Miracle and S.K. Mukherji Conebeam CT of the Head and Neck, Part 2: Clinical Applications AJNR Am. J. Neuroradiol., August 1, 2009; 30(7): 1285 - 1292. [Abstract] [Full Text] [PDF] |
||||
![]() |
A.J. Fox, J. Millar, J. Raymond, J.C. Pryor, D. Roy, G.A. Tomlinson, J.P. McKay, and A.J. Molyneux Dangerous Advances in Measurements from Digital Subtraction Angiography: When Is a Millimeter Not a Millimeter? AJNR Am. J. Neuroradiol., March 1, 2009; 30(3): 459 - 461. [Abstract] [Full Text] [PDF] |
||||
![]() |
A.J. Fox, S.P. Symons, and R.I. Aviv CT Angiography is State-of-the-Art First Vascular Imaging for Subarachnoid Hemorrhage AJNR Am. J. Neuroradiol., June 1, 2008; 29(6): e41 - e42. [Full Text] [PDF] |
||||
![]() |
S. Kakeda, Y. Korogi, Y. Miyaguni, J. Moriya, N. Ohnari, N. Oda, K. Nishino, and W. Miyamoto A Cone-Beam Volume CT Using a 3D Angiography System with a Flat Panel Detector of Direct Conversion Type: Usefulness for Superselective Intra-arterial Chemotherapy for Head and Neck Tumors AJNR Am. J. Neuroradiol., October 1, 2007; 28(9): 1783 - 1788. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Piotin, B. Daghman, C. Mounayer, L. Spelle, and J. Moret Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms. AJNR Am. J. Neuroradiol., April 1, 2006; 27(4): 839 - 842. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Doerfler, I. Wanke, S.L. Goericke, H. Wiedemayer, T. Engelhorn, E.R. Gizewski, D. Stolke, and M. Forsting Endovascular Treatment of Middle Cerebral Artery Aneurysms with Electrolytically Detachable Coils AJNR Am. J. Neuroradiol., March 1, 2006; 27(3): 513 - 520. [Abstract] [Full Text] [PDF] |
||||
![]() |
E.S. Bartlett, T.D. Walters, S.P. Symons, and A.J. Fox Quantification of Carotid Stenosis on CT Angiography AJNR Am. J. Neuroradiol., January 1, 2006; 27(1): 13 - 19. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Racadio, B. L. Fricke, B. V. Jones, and L. F. Donnelly Three-Dimensional Rotational Angiography of Neurovascular Lesions in Pediatric Patients Am. J. Roentgenol., January 1, 2006; 186(1): 75 - 84. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. E. Hyde, A. J. Fox, I. Gulka, P. Kalapos, D. H. Lee, D. M. Pelz, and D. W. Holdsworth Internal Carotid Artery Stenosis Measurement: Comparison of 3D Computed Rotational Angiography and Conventional Digital Subtraction Angiography Stroke, December 1, 2004; 35(12): 2776 - 2781. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. A. Steinman, J. S. Milner, C. J. Norley, S. P. Lownie, and D. W. Holdsworth Image-Based Computational Simulation of Flow Dynamics in a Giant Intracranial Aneurysm AJNR Am. J. Neuroradiol., April 1, 2003; 24(4): 559 - 566. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. U. Ernemann, E. Gronewaller, F. B. Duffner, O. Guervit, J. Claassen, and M. D. Skalej Influence of Geometric and Hemodynamic Parameters on Aneurysm Visualization during Three-Dimensional Rotational Angiography: An in Vitro Study AJNR Am. J. Neuroradiol., April 1, 2003; 24(4): 597 - 603. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Abe, M. Hirohata, N. Tanaka, Y. Uchiyama, K. Kojima, K. Fujimoto, A. M. Norbash, and N. Hayabuchi Clinical Benefits of Rotational 3D Angiography in Endovascular Treatment of Ruptured Cerebral Aneurysm AJNR Am. J. Neuroradiol., April 1, 2002; 23(4): 686 - 688. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C. van den Berg, T. Th. C. Overtoom, J. C. de Valois, and F. L. Moll Using Three-Dimensional Rotational Angiography for Sizing of Covered Stents Am. J. Roentgenol., January 1, 2002; 178(1): 149 - 152. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Anxionnat, S. Bracard, X. Ducrocq, Y. Trousset, L. Launay, E. Kerrien, M. Braun, R. Vaillant, F. Scomazzoni, A. Lebedinsky, et al. Intracranial Aneurysms: Clinical Value of 3D Digital Subtraction Angiography in the Therapeutic Decision and Endovascular Treatment Radiology, March 1, 2001; 218(3): 799 - 808. [Abstract] [Full Text] |
||||
![]() |
H R Seymour, M B Matson, A-M Belli, R Morgan, J Kyriou, and U Patel Rotational digital subtraction angiography of the renal arteries: technique and evaluation in the study of native and transplant renal arteries Br. J. Radiol., February 1, 2001; 74(878): 134 - 141. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. I. Bluth, H. J. M. Barnett, M. Eliasziw, and H. Meldrum Plaque Morphology as a Risk Factor for Stroke JAMA, July 12, 2000; 284(2): 177 - 177. [Full Text] [PDF] |
||||
![]() |
M. El-Sheik, J. T. Heverhagen, H. Alfke, J. J. Froelich, J. Hornegger, T. Brunner, K. J. Klose, and H.-J. Wagner Multiplanar Reconstructions and Three-dimensional Imaging (Computed Rotational Osteography) of Complex Fractures by Using a C-arm System: Initial Results Radiology, December 1, 2001; 221(3): 843 - 849. [Abstract] [Full Text] [PDF] |
||||