AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Melhem, E. R.
Right arrow Articles by Gagliano, T. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Melhem, E. R.
Right arrow Articles by Gagliano, T. A.

American Journal of Neuroradiology, Vol 18, Issue 9 1627-1633, Copyright © 1997 by American Society of Neuroradiology


ARTICLES

Fast inversion-recovery MR: the effect of hybrid RARE readout on the null points of fat and cerebrospinal fluid

ER Melhem, H Jara, H Shakir and TA Gagliano
Department of Radiology, Boston University Medical Center, MA 02118, USA.

PURPOSE: To evaluate the effect of the hybrid RARE (rapid acquisition with relaxation enhancement) readout, commonly coupled to inversion- recovery pulse sequences, on the null inversiton time (TI) of fluid and fat using both phantoms and human volunteers. METHODS: Two phantoms, simulating fat (phantom A) and cerebrospinal fluid (phantom B), respectively, were imaged using a fast inversion-recovery sequence that coupled an inversion-recovery preparation pulse to a hybrid RARE readout. At repetition times (TRs) ranging from 700 to 20,000, the TI necessary to null the signal from each phantom (null TI) was determined for an echo train length of 4, 6, 8, 10, 12, 14, 16, 18, and 20, respectively. Plots of null TI versus echo train length at different TRs were generated for both phantoms. Fast inversion-recovery MR imaging of the cervical spine and brain was performed in healthy volunteers. At a fixed TR and TI, the adequacy of signal suppression from bone marrow and cerebrospinal fluid was assessed as a function of echo train length. RESULTS: There was a gradual decrease of null TI for both phantoms with echo train length. This decrease persisted at longer TRs for phantom B (T1 = 3175 +/- 70 milliseconds) than for phantom A (T1 = 218 +/- 5 milliseconds). In the human volunteers, there was a gradual loss of suppression of signal from bone marrow and cerebrospinal fluid, with changes in the hybrid RARE readout. CONCLUSION: To optimize specific tissue suppression, radiologists implementing fast inversion-recovery MR imaging should be aware of the effects of the hybrid RARE readout on null TI.


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
H.-M. Wu, D. M. Yousem, H.-W. Chung, W.-Y. Guo, C.-Y. Chang, and C.-Y. Chen
Influence of Imaging Parameters on High-Intensity Cerebrospinal Fluid Artifacts in Fast-FLAIR MR Imaging
AJNR Am. J. Neuroradiol., March 1, 2002; 23(3): 393 - 399.
[Abstract] [Full Text] [PDF]