American Journal of Neuroradiology, Vol 19, Issue 10 1863-1867, Copyright © 1998 by American Society of Neuroradiology
ARTICLES |
Sensitivity of enhanced MR in multiple sclerosis: effects of contrast dose and magnetization transfer contrast
S Bastianello, C Gasperini, A Paolillo, E Giugni, O Ciccarelli, MP Sormani, MA Horsfield, M Rovaris, C Pozzilli and M Filippi
Department of Neurological Sciences, University La Sapienza Rome, Italy.
BACKGROUND AND PURPOSES: New strategies have been developed to improve the sensitivity of contrast-enhanced MR imaging in quantifying disease activity in patients with multiple sclerosis (MS). The goal of the present study was to evaluate the sensitivity of T1-weighted images after injection of a triple dose of contrast material and application of a magnetization transfer (MT) pulse in the detection of enhancing lesions as compared with the conventional approach. METHODS: Monthly MR images were obtained in 13 patients with relapsing-remitting MS for a period of 3 months. The MR studies were performed on two separate occasions with single- and triple-dose contrast material. In each session, T1- and T2-weighted spin-echo images with and without the MT pulse were obtained before and after contrast administration. All images were evaluated in a blinded fashion and scored in random order and consensually by two readers. The number of total and new enhancing lesions and active images was counted. RESULTS: Eighty-six percent more enhancing lesions and 54% more new enhancing lesions were detected with triple-dose as compared with single-dose non-MT sequences, whereas single-dose MT images depicted 33% more enhancing lesions and 18% more new enhancing lesions than the single-dose non-MT images. Twenty-nine percent more lesions were detected on triple-dose non-MT images than on single-dose MT images. The combination of a triple dose of contrast material and MT did not produce any significant change in detection of enhancing lesions as compared with a triple dose of contrast without MT. CONCLUSION: The use of a triple dose of contrast material is the best approach to maximize the sensitivity of enhanced MR imaging.
This article has been cited by other articles:
![]() |
F. Sardanelli, A. Iozzelli, C. Losacco, A. Murialdo, and M. Filippi Three Subsequent Single Doses of Gadolinium Chelate for Brain MR Imaging in Multiple Sclerosis AJNR Am. J. Neuroradiol., April 1, 2003; 24(4): 658 - 662. [Abstract] [Full Text] [PDF] |
||||
![]() |
M Filippi Enhanced magnetic resonance imaging in multiple sclerosis Multiple Sclerosis, October 1, 2000; 6(5): 320 - 326. [Abstract] [PDF] |
||||