AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kimura, K.
Right arrow Articles by Otsubo, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kimura, K.
Right arrow Articles by Otsubo, R.

American Journal of Neuroradiology, Vol 19, Issue 10 1893-1896, Copyright © 1998 by American Society of Neuroradiology


ARTICLES

Diagnosis of middle cerebral artery stenosis by transcranial color- coded real-time sonography

K Kimura, M Yasaka, K Wada, K Minematsu, T Yamaguchi and R Otsubo
Department of Medicine, National Cardiovascular Center, Suita, Osaka, Japan.

BACKGROUND & PURPOSE: This study was performed to determine the usefulness of transcranial color-coded real-time sonography (TCCS) in detecting stenosis in the horizontal portion of the middle cerebral artery (MCA). METHODS: Using TCCS and the incident angle correction technique, we measured the peak-systolic flow velocity in bilateral MCAs in 45 consecutive patients in whom cerebral angiography was carried out within 1 week before or after TCCS. Three patients had a stenosis of 75% or greater and four had a unilateral occlusion of the extracranial internal carotid artery (ICA) (the ICS and ICO groups, respectively). Eight patients had a stenosis of 50% or greater (one bilateral and seven unilateral) (the M1S group). Four patients had unilateral distal occlusion of the horizontal portion of the MCA (the M1O group). Twenty-six patients had no significant extra- or intracranial stenosis on the ipsilateral or contralateral side (the control group). RESULTS: Mean peak-systolic flow velocity on the affected side was 83.0 +/- 20.8 cm/s in the ICS group, 59.8 +/- 23.2 cm/s in the ICO group, and 62.3 +/- 33.7 cm/s in the M1O group. In the control group, the mean peak-systolic flow velocity was 116.0 +/- 31.5 cm/s. In the M1S group, however, the mean peak-systolic flow velocity (334.2 +/- 35.7 cm/s) on the affected side always exceeded 180 cm/s (mean value +/- 2 SD in the control group), and was significantly higher than that in the other groups. The mean peak-systolic flow velocity in the M1S group increased with the grade of stenosis. CONCLUSION: The M1S group members could easily be distinguished from the other group members by their peak-systolic flow velocity in excess of 180 cm/s. Measurement of the peak-systolic flow velocity of the MCA by TCCS may help to identify a significant stenosis in the horizontal portion of the MCA.


This article has been cited by other articles:


Home page
J Ultrasound MedHome page
S.-C. Tang, J.-S. Jeng, P.-K. Yip, C.-J. Lu, B.-S. Hwang, W.-H. Lin, and H.-M. Liu
Transcranial Color-Coded Sonography for the Detection of Middle Cerebral Artery Stenosis
J. Ultrasound Med., April 1, 2005; 24(4): 451 - 457.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Koga, K. Kimura, K. Minematsu, and T. Yamaguchi
Relationship between Findings of Conventional and Contrast-Enhanced Transcranial Color-Coded Real-Time Sonography and Angiography in Patients with Basilar Artery Occlusion
AJNR Am. J. Neuroradiol., April 1, 2002; 23(4): 568 - 571.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
C. Klotzsch, A. Bozzato, G. Lammers, M. Mull, and J. Noth
Contrast-Enhanced Three-Dimensional Transcranial Color-Coded Sonography of Intracranial Stenoses
AJNR Am. J. Neuroradiol., February 1, 2002; 23(2): 208 - 212.
[Abstract] [Full Text] [PDF]