AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Filippi, M.
Right arrow Articles by Comi, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Filippi, M.
Right arrow Articles by Comi, G.

American Journal of Neuroradiology, Vol 19, Issue 2 239-244, Copyright © 1998 by American Society of Neuroradiology


ARTICLES

Intraobserver and interobserver variability in schemes for estimating volume of brain lesions on MR images in multiple sclerosis

M Filippi, MA Horsfield, M Rovaris, T Yousry, MA Rocca, C Baratti, S Bressi and G Comi
Department of Neurology, Scientific Institute Ospedale San Raffaele, University of Milan, Italy.

PURPOSE: Our goal was to evaluate the intraobserver and interobserver reproducibility of measurements of brain lesion load in multiple sclerosis (MS) by using two proposed acquisition schemes. METHODS: Three-millimeter-thick conventional spin-echo (CSE) and fast fluid- attenuated inversion-recovery (FLAIR) sequences were obtained and the lesions segmented using a semiautomated technique based on local thresholding to calculate intraobserver and interobserver reproducibility. These were compared with images obtained from two separate MR units in which 5-mm CSE sequences were obtained and segmented by using the local thresholding technique and also by manual outlining. RESULTS: The intraobserver coefficient of variation was 4.0% (95% confidence interval [CI], 3.0% to 4.5%) for the 5-mm CSE sequence measured with manual outlining, 3.1% (95% CI, 2.5% to 3.2%) and 5.1% (95% CI, 4.1% to 5.6%) for the two sets of 5-mm CSE sequences measured using the local thresholding technique, 5.7% (95% CI, 3.9% to 6.6%) for the 3-mm CSE sequence, and 2.6% (95% CI, 2.1% to 2.7%) for the fast FLAIR sequence. The interobserver coefficient of variation was 7.1% (95% CI, 4.9% to 8.7%) and 8.3% (95% CI, 6.4% to 9.6%) for the two sets of 5-mm CSE sequences, 7.3% (95% CI, 4.7% to 9.1%) for the 3-mm CSE sequence, and 2.9% (95% CI, 2.3% to 3.3%) for the fast FLAIR sequence. The intraobserver and interobserver reproducibility of measurements obtained with the fast FLAIR technique was significantly better than those obtained with the other techniques. CONCLUSIONS: Our data indicate that the intraobserver and interobserver variability in quantifying MS lesions can be reduced significantly with the use of fast FLAIR sequences, while no significant improvement is gained by reducing the section thickness from 5 mm to 3 mm.


This article has been cited by other articles:


Home page
Mult SclerHome page
S. Schach, M. Scholz, J.S. Wolinsky, and L. Kappos
Pooled historical MRI data as a basis for research in multiple sclerosis - a statistical evaluation
Multiple Sclerosis, May 1, 2007; 13(4): 509 - 516.
[Abstract] [PDF]


Home page
Am. J. Neuroradiol.Home page
R. Bakshi, S. D. Caruthers, V. Janardhan, and M. Wasay
Intraventricular CSF Pulsation Artifact on Fast Fluid-Attenuated Inversion-Recovery MR Images: Analysis of 100 Consecutive Normal Studies
AJNR Am. J. Neuroradiol., March 1, 2000; 21(3): 503 - 508.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
M. Filippi, M. A. Rocca, M. Wiessmann, S. Mennea, M. Cercignani, T. A. Yousry, M. P. Sormani, and G. Comi
A Comparison of MR Imaging with Fast-FLAIR, HASTE-FLAIR, and EPI-FLAIR Sequences in the Assessment of Patients with Multiple Sclerosis
AJNR Am. J. Neuroradiol., November 1, 1999; 20(10): 1931 - 1938.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
D. M. Moriarty, A. J. Blackshaw, P. R. Talbot, H. L. Griffiths, J. S. Snowden, V. F. Hillier, S. Capener, R. D. Laitt, and A. Jackson
Memory Dysfunction in Multiple Sclerosis Corresponds to Juxtacortical Lesion Load on Fast Fluid-Attenuated Inversion-Recovery MR Images
AJNR Am. J. Neuroradiol., November 1, 1999; 20(10): 1956 - 1962.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
R. Bakshi, S. Kamran, P. R. Kinkel, V. E. Bates, L. L. Mechtler, V. Janardhan, S. L. Belani, and W. R. Kinkel
Fluid-Attenuated Inversion-Recovery MR Imaging in Acute and Subacute Cerebral Intraventricular Hemorrhage
AJNR Am. J. Neuroradiol., April 1, 1999; 20(4): 629 - 636.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
M. Filippi, M. A. Rocca, C. Gasperini, M. P. Sormani, S. Bastianello, M. A. Horsfield, C. Pozzilli, and G. Comi
Interscanner Variation in Brain MR Lesion Load Measurements in Multiple Sclerosis Using Conventional Spin-Echo, Rapid Relaxation-Enhanced, and Fast-FLAIR Sequences
AJNR Am. J. Neuroradiol., January 1, 1999; 20(1): 133 - 137.
[Abstract] [Full Text]