AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Grandin, C. B.
Right arrow Articles by Cosnard, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Grandin, C. B.
Right arrow Articles by Cosnard, G.

American Journal of Neuroradiology, Vol 19, Issue 2 245-252, Copyright © 1998 by American Society of Neuroradiology


ARTICLES

Diagnosis of intracranial aneurysms: accuracy of MR angiography at 0.5 T

CB Grandin, P Mathurin, T Duprez, G Stroobandt, F Hammer, P Goffette and G Cosnard
Department of Medical Imaging, St Luc University Hospital, Catholic University of Louvain, Brussels, Belgium.

PURPOSE: Our goal was to determine the accuracy of MR angiography at 0.5 T for the diagnosis of intracranial aneurysms. METHODS: We retrospectively studied 140 patients, 70 with acute subarachnoid hemorrhage, who were either at high or low risk for intracranial aneurysm. Three-dimensional time-of-flight MR angiography was typically performed to cover the circle of Willis, with a volume thickness of 30 mm. Conventional spin-echo MR images and MR angiograms were reviewed together, and the results were compared with those obtained at intraarterial cerebral angiography to determine the sensitivity and specificity of MR angiography. RESULTS: Eighty-nine aneurysms (size range, 2 to 27 mm; 25 aneurysms < 5 mm) were identified at intraarterial cerebral angiography. Six aneurysms were missed by MR angiography and two were doubtful (sensitivity, 91% to 93%; specificity, 100%). Missed aneurysms were located outside the MR angiographic acquisition volume (n = 3) or on the carotid siphon (n = 3; size = 2, 3, and 5 mm). CONCLUSION: Even if MR angiography presents some restrictions in acquisition volume and spatial resolution, the detection rate of intracranial aneurysms is excellent at 0.5 T in both asymptomatic patients and in those with subarachnoid hemorrhage. A midfield system is not a restriction to the detection of intracranial aneurysms by MR examination.


This article has been cited by other articles:


Home page
RadiologyHome page
W. A. Willinek, M. Born, B. Simon, H. J. Tschampa, C. Krautmacher, J. Gieseke, H. Urbach, H. J. Textor, and H. H. Schild
Time-of-Flight MR Angiography: Comparison of 3.0-T Imaging and 1.5-T Imaging--Initial Experience
Radiology, December 1, 2003; 229(3): 913 - 920.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. M. White, E. M. Teasdale, J. M. Wardlaw, and V. Easton
Intracranial Aneurysms: CT Angiography and MR Angiography for Detection—Prospective Blinded Comparison in a Large Patient Cohort
Radiology, June 1, 2001; 219(3): 739 - 749.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. M. White, J. M. Wardlaw, and V. Easton
Can Noninvasive Imaging Accurately Depict Intracranial Aneurysms? A Systematic Review
Radiology, November 1, 2000; 217(2): 361 - 370.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
C. B. Grandin, G. Cosnard, F. Hammer, T. P. Duprez, G. Stroobandt, and P. Mathurin
Vasospasm after Subarachnoid Hemorrhage: Diagnosis with MR Angiography
AJNR Am. J. Neuroradiol., October 1, 2000; 21(9): 1611 - 1617.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
W. M. Adams, R. D. Laitt, and A. Jackson
The Role of MR Angiography in the Pretreatment Assessment of Intracranial Aneurysms: A Comparative Study
AJNR Am. J. Neuroradiol., October 1, 2000; 21(9): 1618 - 1628.
[Abstract] [Full Text]


Home page
RadiologyHome page
T. Metens, F. Rio, D. Balériaux, T. Roger, P. David, and G. Rodesch
Intracranial Aneurysms: Detection with Gadolinium-enhanced Dynamic Three-dimensional MR Angiography-Initial Results
Radiology, July 1, 2000; 216(1): 39 - 46.
[Abstract] [Full Text]


Home page
StrokeHome page
Y. Yoshimoto and S. Wakai
Cost-Effectiveness Analysis of Screening for Asymptomatic, Unruptured Intracranial Aneurysms : A Mathematical Model
Stroke, August 1, 1999; 30(8): 1621 - 1627.
[Abstract] [Full Text] [PDF]