American Journal of Neuroradiology, Vol 19, Issue 7 1241-1244, Copyright © 1998 by American Society of Neuroradiology
ARTICLES |
Technique for arterial-phase contrast-enhanced three-dimensional MR angiography of the carotid and vertebral arteries
H Isoda, Y Takehara, S Isogai, H Takeda, M Kaneko, A Nozaki, Y Sun and TK Foo
Department of Radiology, Hamamatsu University School of Medicine, Japan.
Our goal was to evaluate whether contrast-enhanced three-dimensional MR angiography using the MR Smartprep technique would enable us to obtain arterial-phase MR angiograms of the carotid and vertebral arteries. The study included 35 patients with suspected lesions of the neck in whom the MR Smartprep technique was used for MR angiography performed with a 1.5-T superconducting system. The tracker volume was placed primarily in the middle part of the right common carotid artery. The imaging volume was placed in a coronal direction to include the carotid and vertebral arteries from the aortic arch to the skull base. A centric phase-ordering scheme was used. Imaging times were 20 to 38 seconds for 14 patients and 11 to 16 seconds for 21 patients. By using a smaller tracker volume and an imaging time of less than 16 seconds, we were able to achieve a 100% successful triggering rate and to delineate selectively arterial-phase carotid and vertebral arteries with almost no venous contamination. Contract-enhanced 3-D MR angiography with the MR Smartprep technique was useful for showing arterial-phase carotid and vertebral arteries selectively.
This article has been cited by other articles:
![]() |
J. Alvarez-Linera, J. Benito-Leon, J. Escribano, J. Campollo, and R. Gesto Prospective Evaluation of Carotid Artery Stenosis: Elliptic Centric Contrast-Enhanced MR Angiography and Spiral CT Angiography Compared with Digital Subtraction Angiography AJNR Am. J. Neuroradiol., May 1, 2003; 24(5): 1012 - 1019. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Remonda, P. Senn, A. Barth, M. Arnold, K.-O. Lovblad, and G. Schroth Contrast-Enhanced 3D MR Angiography of the Carotid Artery: Comparison with Conventional Digital Subtraction Angiography AJNR Am. J. Neuroradiol., February 1, 2002; 23(2): 213 - 219. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. I. Farb, C. McGregor, J. K. Kim, M. Laliberte, J. A. Derbyshire, R. A. Willinsky, P. W. Cooper, D. G. Westman, G. Cheung, M. L. Schwartz, et al. Intracranial Arteriovenous Malformations: Real-Time Auto-triggered Elliptic Centric-ordered 3D Gadolinium-enhanced MR Angiography—Initial Assessment Radiology, July 1, 2001; 220(1): 244 - 251. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. R. Jager, H. Ellamushi, E. A. Moore, J. P. Grieve, N. D. Kitchen, and W. J. Taylor Contrast-enhanced MR Angiography of Intracranial Giant Aneurysms AJNR Am. J. Neuroradiol., November 1, 2000; 21(10): 1900 - 1907. [Abstract] [Full Text] [PDF] |
||||
![]() |
X. Leclerc, L. Nicol, J.-Y. Gauvrit, V. L. Thuc, D. Leys, and J.-P. Pruvo Contrast-enhanced MR Angiography of Supraaortic Vessels: The Effect of Voxel Size on Image Quality AJNR Am. J. Neuroradiol., June 1, 2000; 21(6): 1021 - 1027. [Abstract] [Full Text] |
||||
![]() |
S. J. Riederer, M. A. Bernstein, J. F. Breen, R. F. Busse, R. L. Ehman, S. B. Fain, T. C. Hulshizer, J. H. III, B. F. King, D. G. Kruger, et al. Three-dimensional Contrast-enhanced MR Angiography with Real-time Fluoroscopic Triggering: Design Specifications and Technical Reliability in 330 Patient Studies Radiology, May 1, 2000; 215(2): 584 - 593. [Abstract] [Full Text] |
||||
![]() |
H. Isoda, Y. Takehara, S. Isogai, H. Takeda, T. Tanaka, M. Takahashi, A. Nozaki, and Y. Sun Software-Triggered Contrast-Enhanced Three-Dimensional MR Angiography of the Intracranial Arteries Am. J. Roentgenol., February 1, 2000; 174(2): 371 - 375. [Abstract] [Full Text] [PDF] |
||||


