American Journal of Neuroradiology 20:889-895 (5 1999)
© 1999 American Society of Neuroradiology
ARTICLE
High-Resolution MR Cisternography of the Cerebellopontine Angle: 2D versus 3D Fast Spin-Echo Sequences
a From the Department of Radiology, Nagoya University School of Medicine, Nagoya (E.I., S.N., T.It., H.F., M.I., T.Is.); and Toshiba Corporation, Tokyo (N.I.), Japan.
BACKGROUND AND PURPOSE: The clinical usefulness of MR cisternography of the cerebellopontine angle, applying 2D or 3D fast spin-echo sequences, has been reported recently. Our purpose was to investigate the cause of signal loss in CSF in the prepontine or cerebellopontine angle cistern on 2D FSE MR images and to compare the cisternographic effects of 2D and 3D FSE sequences.
METHODS: Preliminary experiments were performed in four volunteers to assess the causes of signal loss. Initially, using a 2D cardiac-gated cine phase-contrast method with a velocity encoding value of 6 cm/s, we measured the velocity and flow pattern of CSF. Comparisons were made to assess the effects of intravoxel dephasing, amplitude of the section-selecting gradient, echo time (TE), and section thickness. Four healthy subjects and 13 patients with ear symptoms were examined, and multisection 3-mm-thick 2D images and 30-mm-slab, 1-mm-section 3D images were compared qualitatively and quantitatively. Then, 3D MR cisternography was performed in 400 patients with ear symptoms, and qualitative evaluation was performed.
RESULTS: In volunteers, the average peak velocity of CSF was 1.2 cm/s. With TE = 250, CSF may move an average of 3 mm, and can be washed out of a 3-mm-thick 2D section volume. The CSF signal relative to that of a water phantom decreased gradually as TE increased on single-section 3-mm-thick 2D images. The CSF signal relative to that of the water phantom increased gradually as section thickness increased. No significant differences were noted in intravoxel dephasing and amplitude of the section-selecting gradient. The contrast-to-noise ratio (CNR) between CSF and the cerebellar peduncle, and the visibility of the cranial nerves and vertebrobasilar artery were significantly improved on 3D images in 17 subjects. In images from 400 patients, no significant signal loss in the cistern was observed using 3D FSE.
CONCLUSION: CSF signal loss in thin-section 2D MR cisternography is mainly attributable to the wash-out phenomenon. 3D acquisition can reduce this phenomenon and provide thinner sections. The scan time for 3D acquisition is not excessive when a long echo train length and half-Fourier imaging are used. MR cisternography should be performed using a 3D acquisition.
This article has been cited by other articles:
![]() |
V. Nowe, J. L. P. Michiels, R. Salgado, D. De Ridder, P. H. Van de Heyning, A. M. De Schepper, and P. M. Parizel High-Resolution Virtual MR Endoscopy of the Cerebellopontine Angle Am. J. Roentgenol., February 1, 2004; 182(2): 379 - 384. [Full Text] [PDF] |
||||
![]() |
T. Nakamura, S. Naganawa, T. Koshikawa, H. Fukatsu, Y. Sakurai, I. Aoki, A. Ninomiya, and T. Ishigaki High-Spatial-Resolution MR Cisternography of the Cerebellopontine Angle in 90 Seconds with a Zero-Fill Interpolated Fast Recovery 3D Fast Asymmetric Spin-Echo Sequence AJNR Am. J. Neuroradiol., September 1, 2002; 23(8): 1407 - 1412. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Naganawa, T. Koshikawa, H. Fukatsu, T. Ishigaki, I. Aoki, and A. Ninomiya Fast Recovery 3D Fast Spin-Echo MR Imaging of the Inner Ear at 3 T AJNR Am. J. Neuroradiol., February 1, 2002; 23(2): 299 - 302. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Naganawa, T. Koshikawa, H. Fukatsu, T. Ishigaki, and T. Fukuta MR Cisternography of the Cerebellopontine Angle: Comparison of Three-dimensional Fast Asymmetrical Spin-echo and Three-dimensional Constructive Interference in the Steady-state Sequences AJNR Am. J. Neuroradiol., June 1, 2001; 22(6): 1179 - 1185. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Naganawa, T. Koshikawa, E. Iwayama, H. Fukatsu, T. Ishiguchi, T. Ishigaki, M. Ikeda, T. Nakashima, and N. Ichinose MR Imaging of the Enlarged Endolymphatic Duct and Sac Syndrome by Use of a 3D Fast Asymmetric Spin-echo Sequence: Volume and Signal-intensity Measurement of the Endolymphatic Duct and Sac and Area Measurement of the Cochlear Modiolus AJNR Am. J. Neuroradiol., October 1, 2000; 21(9): 1664 - 1669. [Abstract] [Full Text] |
||||
![]() |
D. Yang, Y. Korogi, Y. Ushio, and M. Takahashi Increased Conspicuity of Intraventricular Lesions Revealed by Three-dimensional Constructive Interference in Steady State Sequences AJNR Am. J. Neuroradiol., June 1, 2000; 21(6): 1070 - 1072. [Abstract] [Full Text] |
||||

