AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meyer, J. R.
Right arrow Articles by Homer, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Meyer, J. R.
Right arrow Articles by Homer, D.

ARTICLE

High-b-value Diffusion-weighted MR Imaging of Suspected Brain Infarction

Joel R. Meyera,b, Arturo Gutierreza, Bryan Mocka, Delon Hebrona, Jordan M. Pragera, Michael T. Goreya and Daniel Homera

a From the Departments of Radiology (J.R.M., A.G., D.H., J.M.P., M.T.G.) and Neurology (J.R.M., D.H.), Northwestern University Medical School, Evanston, IL, and GE Medical Systems (B.M.), Milwaukee, WI.
b Address reprint requests to Joel R. Meyer, M.D., Department of Radiology, Evanston Northwestern Healthcare, 2650 Ridge Ave., Evanston, IL 60201.

BACKGROUND AND PURPOSE: Recent technological advances in MR instrumentation allow acquisition of whole-brain diffusion-weighted MR scans to be obtained with b values greater than 1000. Our purpose was to determine whether high-b-value diffusion-weighted MR imaging improved contrast and detection of signal changes in acute and chronic brain infarction.

METHODS: We prospectively evaluated the MR scans of 30 subjects with a history of possible brain infarction on a 1.5-T MR imager with 40 mT/meter gradients (slew rate 150 T/m/s) by use of the following single-shot echo-planar diffusion-weighted MR sequences: 1) 7999/71.4/1 (TR/TE/excitations, b = 1000; 2) 999/ 88.1/3, b = 2500; and 3) 7999/ 92.1/4, b = 3000. Diffusion-weighted MR imaging was performed in three orthogonal directions during all sequences. All subjects were scanned with fast fluid-attenuated inversion recovery (FLAIR) (10,006/145/2200/1 [TR/TE/TI/excitations]) and fast spin-echo T2-weighted (3650/95/3 [TR/TE/excitations], echo train length, 8). The diagnosis of brain infarction was established by clinical criteria.

RESULTS: Twenty women and 10 men with a mean age of 67.7 years were enrolled in the study. One subject was excluded owing to poor image quality. Twelve of 29 subjects had a clinical diagnosis of acute infarction. All 12 had lesions that were hyperintense on diffusion-weighted images at all three b values; five were cortical and seven subcortical. There was increased contrast of all lesions on high-b-value scans (b = 2500 and 3000). Lesions that were hypointense on diffusion-weighted images were identified and evaluated at the three different b values. At b = 1000, there were 19 hypointense lesions, whereas at b = 2500 and 3000 there were 48 and 55 lesions, respectively. On FLAIR and T2-weighted images, these low-signal lesions were predominantly chronic, subcortical, ischemic lesions and lacunar infarcts, but four chronic cortical infarcts, one porencephalic cyst, and one primary brain tumor were also found. Low-signal lesions were also noted to have increased contrast on high-b-value diffusion-weighted scans.

CONCLUSION: High-b-value diffusion-weighted MR imaging (b = 2500 or b = 3000) had no impact on diagnosis of acute infarction. High-b-value diffusion-weighted MR imaging (b = 2500) combined with diffusion-weighted MR imaging at b = 1000 improves tissue characterization by increasing the spectrum of observed imaging abnormalities in patients with suspected brain infarction.




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
H.S. Seo, K.-H. Chang, D.G. Na, B.J. Kwon, and D.H. Lee
High b-Value Diffusion (b = 3000 s/mm2) MR Imaging in Cerebral Gliomas at 3T: Visual and Quantitative Comparisons with b = 1000 s/mm2
AJNR Am. J. Neuroradiol., March 1, 2008; 29(3): 458 - 463.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. E. Chen, J. E. Simon, M. D. Hill, C.-H. Sohn, P. Dickhoff, W. F. Morrish, R. J. Sevick, and R. Frayne
Acute Ischemic Stroke: Accuracy of Diffusion-weighted MR Imaging--Effects of b Value and Cerebrospinal Fluid Suppression
Radiology, January 1, 2006; 238(1): 232 - 239.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
K. K. Tha, S. Terae, T. Yamamoto, K. Kudo, C. Takahashi, M. Oka, S. Uegaki, and K. Miyasaka
Early Detection of Global Cerebral Anoxia: Improved Accuracy by High-b-Value Diffusion-Weighted Imaging with Long Echo Time
AJNR Am. J. Neuroradiol., June 1, 2005; 26(6): 1487 - 1497.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
H. J. Kim, C. G. Choi, D. H. Lee, J. H. Lee, S. J. Kim, and D. C. Suh
High-b-Value Diffusion-Weighted MR Imaging of Hyperacute Ischemic Stroke at 1.5T
AJNR Am. J. Neuroradiol., February 1, 2005; 26(2): 208 - 215.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. K. Kuhl, J. Gieseke, M. von Falkenhausen, J. Textor, S. Gernert, C. Sonntag, and H. H. Schild
Sensitivity Encoding for Diffusion-weighted MR Imaging at 3.0 T: Intraindividual Comparative Study
Radiology, February 1, 2005; 234(2): 517 - 526.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
P. Brugieres, P. Thomas, A. Maraval, H. Hosseini, C. Combes, A. Chafiq, L. Ruel, S. Breil, M. Peschanski, and A. Gaston
Water Diffusion Compartmentation at High b Values in Ischemic Human Brain
AJNR Am. J. Neuroradiol., May 1, 2004; 25(5): 692 - 698.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A. K. Kamal, A. Z. Segal, and A. M. Ulug
Quantitative Diffusion-Weighted MR Imaging in Transient Ischemic Attacks
AJNR Am. J. Neuroradiol., October 1, 2002; 23(9): 1533 - 1538.
[Abstract] [Full Text] [PDF]