AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Aoki, S.
Right arrow Articles by Araki, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Aoki, S.
Right arrow Articles by Araki, T.

ARTICLE

Dynamic Contrast-Enhanced MR Angiography and MR Imaging of the Carotid Artery: High-Resolution Sequences in Different Acquisition Planes

Shigeki Aoki,a, Hiroto Nakajimaa, Hiroshi Kumagaia and Tsutomu Arakia

a From the Department of Radiology, Yamanashi Medical University, 1110 Shimokato, Tamaho-cho, Nakakoma-gun, Yamanashi, 409-3898, Japan.

BACKGROUND AND PURPOSE: First-pass contrast-enhanced MR angiography has become the technique of choice for studying the carotid bifurcation, but this method has some limitations. We evaluated the clinical utility of performing 3D contrast-enhanced MR angiography in the axial plane immediately after performing angiography in the coronal plane.

METHODS: Cervical carotid arteries of 80 consecutive patients were studied on a 1.5-T MR imager with phased-array coils. Coronal 3D MR angiography was performed after administering a bolus injection of contrast material (20 mL) with automatic triggering. This was immediately followed by an axial acquisition. We measured carotid diameters on the contrast-enhanced MR angiograms as well as on intra-arterial digital subtraction angiograms according to established criteria. We also evaluated original source MR angiograms.

RESULTS: Angiograms obtained in the axial plane correlated better with the intra-arterial digital subtraction angiograms than did the coronal angiograms. When first-pass contrast-enhanced MR angiography was incomplete because of a failure of triggering, the second-phase acquisition provided sufficient image quality. Original source images suffered from ring artifacts, low axial resolution, and a low level of soft-tissue visualization. Axial-based source images showed flow-independent contrast filling to the patent lumen with sufficient visualization of plaque morphology, thickened arterial wall, and surrounding disease processes, such as tumors.

CONCLUSION: With the addition of a 1-minute second-phase 3D acquisition in a different plane immediately after first-pass contrast-enhanced MR angiography, one can obtain a more accurate depiction of the carotid bifurcation, insurance against failure of triggering, and diagnostic source images.




This article has been cited by other articles:


Home page
RadiologyHome page
M. Anzidei, A. Napoli, B. C. Marincola, I. Nofroni, D. Geiger, F. Zaccagna, C. Catalano, and R. Passariello
Gadofosveset-enhanced MR Angiography of Carotid Arteries: Does Steady-State Imaging Improve Accuracy of First-Pass Imaging? Comparison with Selective Digital Subtraction Angiography
Radiology, May 1, 2009; 251(2): 457 - 466.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
N. Horie, M. Morikawa, N. Kitigawa, K. Tsutsumi, M. Kaminogo, and I. Nagata
2D Thick-Section MR Digital Subtraction Angiography for the Assessment of Dural Arteriovenous Fistulas.
AJNR Am. J. Neuroradiol., February 1, 2006; 27(2): 264 - 269.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
C. W. Yang, J. C. Carr, S. F. Futterer, M. D. Morasch, B. P. Yang, S. M. Shors, and J. P. Finn
Contrast-Enhanced MR Angiography of the Carotid and Vertebrobasilar Circulations
AJNR Am. J. Neuroradiol., September 1, 2005; 26(8): 2095 - 2101.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
G. M Hathout, M. J. Duh, and S. M. El-Saden
Accuracy of Contrast-Enhanced MR Angiography in Predicting Angiographic Stenosis of the Internal Carotid Artery: Linear Regression Analysis
AJNR Am. J. Neuroradiol., October 1, 2003; 24(9): 1747 - 1756.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Zhang, J. Cai, Y. Luo, C. Han, N. L. Polissar, T. S. Hatsukami, and C. Yuan
Measurement of Carotid Wall Volume and Maximum Area with Contrast-enhanced 3D MR Imaging: Initial Observations
Radiology, July 1, 2003; 228(1): 200 - 205.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J. Alvarez-Linera, J. Benito-Leon, J. Escribano, J. Campollo, and R. Gesto
Prospective Evaluation of Carotid Artery Stenosis: Elliptic Centric Contrast-Enhanced MR Angiography and Spiral CT Angiography Compared with Digital Subtraction Angiography
AJNR Am. J. Neuroradiol., May 1, 2003; 24(5): 1012 - 1019.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. C. Carr, J. Ma, V. Desphande, S. Pereles, G. Laub, and J. P. Finn
High-Resolution Breath-Hold Contrast-Enhanced MR Angiography of the Entire Carotid Circulation
Am. J. Roentgenol., March 1, 2002; 178(3): 543 - 549.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
L. Remonda, P. Senn, A. Barth, M. Arnold, K.-O. Lovblad, and G. Schroth
Contrast-Enhanced 3D MR Angiography of the Carotid Artery: Comparison with Conventional Digital Subtraction Angiography
AJNR Am. J. Neuroradiol., February 1, 2002; 23(2): 213 - 219.
[Abstract] [Full Text] [PDF]