AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Noguchi, K.
Right arrow Articles by Watanabe, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Noguchi, K.
Right arrow Articles by Watanabe, N.

ARTICLE

Comparison of Fluid-attenuated Inversion-recovery MR Imaging with CT in a Simulated Model of Acute Subarachnoid Hemorrhage

Kyo Noguchi,a, Hikaru Setoa, Yuichi Kamisakia, Gakuto Tomizawaa, Shinichiro Toyoshimaa and Naoto Watanabea

a From the Department of Radiology, Toyama Medical and Pharmaceutical University, Toyama, Japan.

BACKGROUND AND PURPOSE: Because MR imaging is becoming integral to the evaluation and treatment of very early stroke, it is critical to prove that MR imaging is at least as sensitive to acute subarachnoid hemorrhage (SAH) as is CT. The present study was conducted to evaluate the possibility of detecting a small amount of acute SAH diluted by CSF not revealed by CT but identified on fluid-attenuated inversion-recovery (FLAIR) MR images in an in vitro study.

METHODS: Acute SAH was simulated with mixtures of artificial CSF and arterial blood (hematocrit [Hct], 45%) ranging from 0% to 100% by volume. We scanned these phantoms with CT and turbo-FLAIR MR imaging (9000/119 [TR/effective TE]; inversion time, 2200 ms; echo train length, 7), and we measured T1 and T2 relaxation times of these phantoms at temperatures within 36° C to 37° C. Plots of CT value from the different blood/water mixture ratios versus Hct were generated and correlated with the average CT value from normal cortex. We measured T1 and T2 relaxation times of these phantoms and normal cortex and generated T2 relaxation curves as a function of effective TE for a specific inversion time (2200), and determined the TR (9000) for the turbo-FLAIR sequence by using a theoretical equation for the turbo inversion recovery signal intensity.

RESULTS: Above a Hct of 27% blood, the mixture was denser on CT scans than was the normal cortex. At a selected time longer than an effective TE of 120, above a Hct of 22.4% blood, the mixture was more hyperintense than the normal cortex on turbo-FLAIR images. At selected times longer than an effective TE of 160, above a Hct of 9% blood, the mixture was more hyperintense than was the normal cortex.

CONCLUSION: FLAIR imaging is more sensitive than CT in the detection of a small amount of acute SAH diluted by CSF at selected appropriate TE, as determined in an in vitro study.




This article has been cited by other articles:


Home page
StrokeHome page
E. S. Roach, M. R. Golomb, R. Adams, J. Biller, S. Daniels, G. deVeber, D. Ferriero, B. V. Jones, F. J. Kirkham, R. M. Scott, et al.
Management of Stroke in Infants and Children: A Scientific Statement From a Special Writing Group of the American Heart Association Stroke Council and the Council on Cardiovascular Disease in the Young
Stroke, September 1, 2008; 39(9): 2644 - 2691.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. L. Stuckey, T. D. Goh, T. Heffernan, and D. Rowan
Hyperintensity in the Subarachnoid Space on FLAIR MRI
Am. J. Roentgenol., October 1, 2007; 189(4): 913 - 921.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A. Cianfoni, M.G.M. Martin, J. Du, J.R. Hesselink, S.G. Imbesi, W.G. Bradley, and G.M. Bydder
Artifact simulating subarachnoid and intraventricular hemorrhage on single-shot, fast spin-echo fluid-attenuated inversion recovery images caused by head movement: A trap for the unwary.
AJNR Am. J. Neuroradiol., April 1, 2006; 27(4): 843 - 849.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Mohamed, D. C. Heasely, B. Yagmurlu, and D. M. Yousem
Fluid-Attenuated Inversion Recovery MR Imaging and Subarachnoid Hemorrhage: Not a Panacea
AJNR Am. J. Neuroradiol., April 1, 2004; 25(4): 545 - 550.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
D. Iancu-Gontard, C. Oppenheim, E. Touze, E. Meary, M. Zuber, J.-L. Mas, D. Fredy, and J.-F. Meder
Evaluation of Hyperintense Vessels on FLAIR MRI for the Diagnosis of Multiple Intracerebral Arterial Stenoses
Stroke, August 1, 2003; 34(8): 1886 - 1891.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
R. T. Higashida and A. J. Furlan
Trial Design and Reporting Standards for Intra-Arterial Cerebral Thrombolysis for Acute Ischemic Stroke
Stroke, August 1, 2003; 34 (8): e109 - e137.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
D J A Connolly, D Birchall, and A Gholkar
Current theory in imaging of intracranial vascular disease
Imaging, October 1, 2002; 14(5): 396 - 408.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
D. D. M. Lin, C. G. Filippi, A. B. Steever, and R. D. Zimmerman
Detection of Intracranial Hemorrhage: Comparison between Gradient-echo Images and b0 Images Obtained from Diffusion-weighted Echo-planar Sequences
AJNR Am. J. Neuroradiol., August 1, 2001; 22(7): 1275 - 1281.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A. H. Herlihy, J. V. Hajnal, W. L. Curati, N. Virji, A. Oatridge, B. K. Puri, and G. M. Bydder
Reduction of CSF and Blood Flow Artifacts on FLAIR Images of the Brain with k-Space Reordered by Inversion Time at each Slice Position (KRISP)
AJNR Am. J. Neuroradiol., May 1, 2001; 22(5): 896 - 904.
[Abstract] [Full Text]