American Journal of Neuroradiology 22:99-102 (1 2001)
© 2001 American Society of Neuroradiology
ARTICLE
Monocrystalline Iron Oxide Nanoparticles: Possible Solution to the Problem of Surgically Induced Intracranial Contrast Enhancement in Intraoperative MR Imaging
a From the Departments of Neuroradiology (M.K., T.E., K.S.), Neuropathology (S.U.R.), and Neurosurgery (C.R.W.), University of Heidelberg Medical School, Heidelberg, Germany.
BACKGROUND AND PURPOSE: Intraoperative MR imaging is increasingly being used to control the extent of surgical resection; however, surgical manipulation itself causes intracranial contrast enhancement, which is a source of error. Our purpose was to investigate the potential of monocrystalline iron oxide nanoparticles (MIONs) to solve this problem in an animal model.
METHODS: In male Wistar rats, surgical lesions of the brain were produced. The animals underwent MR examination immediately afterward. In the first group, a paramagnetic contrast agent was administered, whereas the second group of animals received MIONs 1 day before surgery. In a third group of animals, malignant glioma cells were stereotactically implanted in the caudoputamen. Two weeks later, MIONs were IV injected and the tumor was (partially) resected. Immediately after resection, MR examination was performed to determine the extent of residual tumor.
RESULTS: Surgically induced intracranial contrast enhancement was seen in all animals in which a paramagnetic contrast agent was used. Conversely, when MIONs had been injected, no signal changes that could be confused with residual tumor were detected. In the animals that had undergone (partial) resection of experimental gliomas, MR assessment of residual tumor was possible without any interfering surgically induced phenomena.
CONCLUSION: Because MIONs are stored in malignant brain tumor cells longer than they circulate in the blood, their use offers a promising strategy to avoid surgically induced intracranial contrast enhancement, which is known to be a potential source of error in intraoperative MR imaging.
This article has been cited by other articles:
![]() |
R. L. Ehman, W. R. Hendee, M. J. Welch, N. R. Dunnick, L. B. Bresolin, R. L. Arenson, S. Baum, H. Hricak, and J. H. Thrall Blueprint for Imaging in Biomedical Research Radiology, July 1, 2007; 244(1): 12 - 27. [Full Text] [PDF] |
||||
![]() |
I. Nolte, G. H. Vince, M. Maurer, C. Herbold, R. Goldbrunner, L. Solymosi, G. Stoll, and M. Bendszus Iron Particles Enhance Visualization of Experimental Gliomas with High-Resolution Sonography AJNR Am. J. Neuroradiol., June 1, 2005; 26(6): 1469 - 1474. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Hunt, A. G. Bago, and E. A. Neuwelt Single-Dose Contrast Agent for Intraoperative MR Imaging of Intrinsic Brain Tumors by Using Ferumoxtran-10 AJNR Am. J. Neuroradiol., May 1, 2005; 26(5): 1084 - 1088. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. F. Kircher, U. Mahmood, R. S. King, R. Weissleder, and L. Josephson A Multimodal Nanoparticle for Preoperative Magnetic Resonance Imaging and Intraoperative Optical Brain Tumor Delineation Cancer Res., December 1, 2003; 63(23): 8122 - 8125. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Varallyay, G. Nesbit, L. L. Muldoon, R. R. Nixon, J. Delashaw, J. I. Cohen, A. Petrillo, D. Rink, and E. A. Neuwelt Comparison of Two Superparamagnetic Viral-Sized Iron Oxide Particles Ferumoxides and Ferumoxtran-10 with a Gadolinium Chelate in Imaging Intracranial Tumors AJNR Am. J. Neuroradiol., April 1, 2002; 23(4): 510 - 519. [Abstract] [Full Text] [PDF] |
||||