AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hajnal, J. V.
Right arrow Articles by Bydder, G. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hajnal, J. V.
Right arrow Articles by Bydder, G. M.

ARTICLE

Reduction of CSF Artifacts on FLAIR Images by Using Adiabatic Inversion Pulses

Joseph V. Hajnala, Angela Oatridgea, Amy H. Herlihya and Graeme M. Byddera

a From the Robert Steiner Magnetic Resonance Unit, MRC Clinical Sciences Centre, Imperial College School of Medicine, Hammersmith Campus, Du Cane Rd, London W12 0HS, UK.

Summary: The purpose of this study was to investigate the possibility that some artifactual high signals produced in CSF with fluid-attenuated inversion-recovery MR sequences could be due to inhomogeneity in the amplitude of the initial inversion pulse, and that this problem could be reduced or eliminated by the use of adiabatic inversion pulses. Studies with four volunteers showed dependence of high CSF signals in the posterior fossa on radiofrequency pulse amplitudes and that these signals could be eliminated by the use of adiabatic inversion pulses. Two illustrative clinical cases are included.




This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
K K THA, S TERAE, K KUDO, and K MIYASAKA
Differential diagnosis of hyperintense cerebrospinal fluid on fluid-attenuated inversion recovery images of the brain. Part II: non-pathological conditions
Br. J. Radiol., July 1, 2009; 82(979): 610 - 614.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. L. Stuckey, T. D. Goh, T. Heffernan, and D. Rowan
Hyperintensity in the Subarachnoid Space on FLAIR MRI
Am. J. Roentgenol., October 1, 2007; 189(4): 913 - 921.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A. Cianfoni, M.G.M. Martin, J. Du, J.R. Hesselink, S.G. Imbesi, W.G. Bradley, and G.M. Bydder
Artifact simulating subarachnoid and intraventricular hemorrhage on single-shot, fast spin-echo fluid-attenuated inversion recovery images caused by head movement: A trap for the unwary.
AJNR Am. J. Neuroradiol., April 1, 2006; 27(4): 843 - 849.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
H.-M. Wu, D. M. Yousem, H.-W. Chung, W.-Y. Guo, C.-Y. Chang, and C.-Y. Chen
Influence of Imaging Parameters on High-Intensity Cerebrospinal Fluid Artifacts in Fast-FLAIR MR Imaging
AJNR Am. J. Neuroradiol., March 1, 2002; 23(3): 393 - 399.
[Abstract] [Full Text] [PDF]