AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hopper, K. D.
Right arrow Articles by Kunselman, A. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hopper, K. D.
Right arrow Articles by Kunselman, A. R.

ARTICLE

Radioprotection to the Eye During CT Scanning

Kenneth D. Hoppera, Joel D. Neumana, Steven H. Kinga and Allen R. Kunselmana

a From the Department of Radiology (K.D.H.), Health Physics Division (S.H.K.), and Health Evaluation Sciences (A.R.K.), Penn State University, Hershey, PA, and the Department of Radiology (J.D.N.), Geisinger Wyoming Valley Hospital, Wilkes Barre, PA.

BACKGROUND AND PURPOSE: The lens of the eye is sensitive to radiation. Children undergoing CT of the head and patients undergoing repeated CT scanning of the head are vulnerable to this complication. The purpose of this study was to test the ability of a heavy metal, bismuth, in reducing radiation to the lens of the eye during routine cranial CT.

METHODS: Both phantom and human studies were done. Using a standard head-attenuating phantom, scanning was performed with detectors placed over the eye, first without the protectors, and then with shielding by one (1T), two (2T), or three thickness (3T) of bismuth-coated latex. The patient study included 30 patients randomized into one of three groups with eye protection provided by 1T, 2T, or 3T of the bismuth-coated latex. Control measurements were done using thermoluminescent dosimeters over the forehead above each eye. Image artifact from the bismuth shields was assessed.

RESULTS: The phantom study demonstrated that the use of bismuth-coated shielding over the eyes decreased radiation dosage by 48.5%, 59.8%, and 65.4% using 1T, 2T, and 3T, respectively. The effect of eye shielding in decreasing radiation dosage to the eye was highly significant for all three thicknesses (P = 2.9 x 10-81 to 1.9 x 10-89). In the patient study, the use of 1T, 2T, and 3T of bismuth-coated latex saved an average radiation dose of 39.6%, 43.5%, and 52.8%, respectively. While the use of shielding was statistically significant in saving radiation for all thicknesses (P = 2.2 x 10-10 to 1.4 x 10-21), there was no statistical difference between 1T, 2T, and 3T of bismuth-coated latex shielding found in patients. However, the trend was for increased radiation savings to the eye with increased thickness of shielding used. A review of all 30 studies showed no significant artifact caused by the eye shielding, regardless of thickness.

CONCLUSION: Bismuth-coated latex shielding of the eye during cranial CT is simple to apply, inexpensive, and causes up to a 50% reduction in radiation to the lens of the eye.




This article has been cited by other articles:


Home page
RadiologyHome page
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Radiology, July 1, 2008; 248(1): 254 - 263.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. E. Ngaile, C. B. S. Uiso, P. Msaki, and R. Kazema
USE OF LEAD SHIELDS FOR RADIATION PROTECTION OF SUPERFICIAL ORGANS IN PATIENTS UNDERGOING HEAD CT EXAMINATIONS
Radiat Prot Dosimetry, March 28, 2008; (2008) ncn095v1.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E V Kennedy, G R Iball, and D S Brettle
Investigation into the effects of lead shielding for fetal dose reduction in CT pulmonary angiography
Br. J. Radiol., August 1, 2007; 80(956): 631 - 638.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. H. Brem, A. A. Zamani, R. Riva, K. H. Zou, Z. Rumboldt, F. F. Hennig, R. Kikinis, A. M. Norbash, and U. J. Schoepf
Multidetector CT of the Paranasal Sinus: Potential for Radiation Dose Reduction
Radiology, June 1, 2007; 243(3): 847 - 852.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Mukundan Jr., P. I. Wang, D. P. Frush, T. Yoshizumi, J. Marcus, E. Kloeblen, and M. Moore
MOSFET Dosimetry for Radiation Dose Assessment of Bismuth Shielding of the Eye in Children
Am. J. Roentgenol., June 1, 2007; 188(6): 1648 - 1650.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
M A Lewis and S Edyvean
Patient dose reduction in CT
Br. J. Radiol., October 1, 2005; 78(934): 880 - 883.
[Full Text] [PDF]