AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gonen, O.
Right arrow Articles by Moser, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gonen, O.
Right arrow Articles by Moser, E.

ARTICLE

Multivoxel 3D Proton Spectroscopy in the Brain at 1.5 Versus 3.0 T: Signal-to-Noise Ratio and Resolution Comparison

Oded Gonena, Stephan Grubera, Belinda S. Y. Lia, Vladimir Mlynárika and Ewald Mosera

a From the Fox Chase Cancer Center (O.G., B.S.Y.L.), Philadelphia, and the Institut für Medizinische Physik (S.G., V.M., E.M.), Universität Wien, Austria.

BACKGROUND AND PURPOSE: The new 3.0-T imagers theoretically yield double the signal-to-noise ratio (SNR) and spectral resolution of 1.5-T instruments. To assess the possible improvements for multivoxel 3D proton MR spectroscopy (1H-MRS) in the human brain, we compared the SNR and spectral resolution performance with both field strengths.

METHODS: Three-dimensional 1H-MRS was performed in four 21–29-year-old subjects at 1.5 and 3.0 T. In each, a volume of interest of 9 x 9 x 3 cm was obtained within a field of view of 16 x 16 x 3 cm that was partitioned into four (0.75-cm-thick) 16 x 16-voxel sections, yielding 324 (0.75-cm3) signal voxels per examination.

RESULTS: In an acquisition protocol of approximately 27 min, average voxel SNRs increased 23–46% at 3.0 versus 1.5 T in the same brain regions of the same subjects. SNRs for N-acetylaspartate, creatine, and choline, respectively, were as follows: 15.3 ± 4, 8.2 ± 2.2, and 8.0 ± 2.0 at 1.5 T and 22.4 ± 7.0, 10.1 ± 3.5, and 10.1 ± 3.6 at 3.0 T. Spectral resolution (metabolite linewidths) were 3.5 ± 0.5 Hz at 1.5 T versus 6.1 ± 1.5 Hz at 3.0 T in approximately 900 voxels. Spectral baselines were noticeably flatter at 3.0 T.

CONCLUSION: Expected gains in SNR and spectral resolution were not fully realized in a realistic experiment because of intrinsic and controllable factors. However, the 23–46% improvements obtained enable more reliable peak-area estimation and an 1H-MRS acquisition approximately 50% shorter at 3.0 versus 1.5 T.




This article has been cited by other articles:


Home page
RadioGraphicsHome page
K. J. Chang, I. R. Kamel, K. J. Macura, and D. A. Bluemke
3.0-T MR Imaging of the Abdomen: Comparison with 1.5 T
RadioGraphics, November 1, 2008; 28(7): 1983 - 1998.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. F. Faria, S. M. Goldman, J. Szejnfeld, H. Melo, C. Kater, P. Kenney, M. P. Huayllas, G. Demarchi, V. V. Francisco, C. Andreoni, et al.
Adrenal Masses: Characterization with in Vivo Proton MR Spectroscopy Initial Experience
Radiology, December 1, 2007; 245(3): 788 - 797.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M.P. Wattjes, M. Harzheim, G.G. Lutterbey, L. Klotz, H.H. Schild, and F. Traber
Axonal Damage But No Increased Glial Cell Activity in the Normal-Appearing White Matter of Patients with Clinically Isolated Syndromes Suggestive of Multiple Sclerosis Using High-Field Magnetic Resonance Spectroscopy
AJNR Am. J. Neuroradiol., September 1, 2007; 28(8): 1517 - 1522.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. M. Fayad, P. B. Barker, M. A. Jacobs, J. Eng, K. L. Weber, P. Kulesza, and D. A. Bluemke
Characterization of Musculoskeletal Lesions on 3-T Proton MR Spectroscopy
Am. J. Roentgenol., June 1, 2007; 188(6): 1513 - 1520.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J.-h. Kim, K.-H. Chang, D.G. Na, I.C. Song, B.J. Kwon, M.H. Han, and K. Kim
3T 1H-MR Spectroscopy in Grading of Cerebral Gliomas: Comparison of Short and Intermediate Echo Time Sequences
AJNR Am. J. Neuroradiol., August 1, 2006; 27(7): 1412 - 1418.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Inglese, M. Spindler, J.S. Babb, P. Sunenshine, M. Law, and O. Gonen
Field, Coil, and Echo-Time Influence on Sensitivity and Reproducibility of Brain Proton MR Spectroscopy
AJNR Am. J. Neuroradiol., March 1, 2006; 27(3): 684 - 688.
[Abstract] [Full Text] [PDF]


Home page
NeurologyHome page
L. L. Chao, N. Schuff, J. H. Kramer, A. T. Du, A. A. Capizzano, J. O'Neill, O. M. Wolkowitz, W. J. Jagust, H. C. Chui, B. L. Miller, et al.
Reduced medial temporal lobe N-acetylaspartate in cognitively impaired but nondemented patients
Neurology, January 25, 2005; 64(2): 282 - 289.
[Abstract] [Full Text] [PDF]


Home page
The OncologistHome page
K. E. Warren
NMR Spectroscopy and Pediatric Brain Tumors
Oncologist, June 1, 2004; 9(3): 312 - 318.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J. S. Ross
The High-Field-Strength Curmudgeon
AJNR Am. J. Neuroradiol., February 1, 2004; 25(2): 168 - 169.
[Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
O. Gonen
Higher Field Strength for Proton MR Spectroscopy
AJNR Am. J. Neuroradiol., May 1, 2003; 24(5): 781 - 782.
[Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
K. Kantarci, G. Reynolds, R. C. Petersen, B. F. Boeve, D. S. Knopman, S. D. Edland, G. E. Smith, R. J. Ivnik, E. G. Tangalos, and C. R. Jack Jr
Proton MR Spectroscopy in Mild Cognitive Impairment and Alzheimer Disease: Comparison of 1.5 and 3 T
AJNR Am. J. Neuroradiol., May 1, 2003; 24(5): 843 - 849.
[Abstract] [Full Text] [PDF]