American Journal of Neuroradiology 22:1727-1731 (October 2001)
© 2001 American Society of Neuroradiology
ARTICLE
Multivoxel 3D Proton Spectroscopy in the Brain at 1.5 Versus 3.0 T: Signal-to-Noise Ratio and Resolution Comparison
a From the Fox Chase Cancer Center (O.G., B.S.Y.L.), Philadelphia, and the Institut für Medizinische Physik (S.G., V.M., E.M.), Universität Wien, Austria.
BACKGROUND AND PURPOSE: The new 3.0-T imagers theoretically yield double the signal-to-noise ratio (SNR) and spectral resolution of 1.5-T instruments. To assess the possible improvements for multivoxel 3D proton MR spectroscopy (1H-MRS) in the human brain, we compared the SNR and spectral resolution performance with both field strengths.
METHODS: Three-dimensional 1H-MRS was performed in four 2129-year-old subjects at 1.5 and 3.0 T. In each, a volume of interest of 9 x 9 x 3 cm was obtained within a field of view of 16 x 16 x 3 cm that was partitioned into four (0.75-cm-thick) 16 x 16-voxel sections, yielding 324 (0.75-cm3) signal voxels per examination.
RESULTS: In an acquisition protocol of approximately 27 min, average voxel SNRs increased 2346% at 3.0 versus 1.5 T in the same brain regions of the same subjects. SNRs for N-acetylaspartate, creatine, and choline, respectively, were as follows: 15.3 ± 4, 8.2 ± 2.2, and 8.0 ± 2.0 at 1.5 T and 22.4 ± 7.0, 10.1 ± 3.5, and 10.1 ± 3.6 at 3.0 T. Spectral resolution (metabolite linewidths) were 3.5 ± 0.5 Hz at 1.5 T versus 6.1 ± 1.5 Hz at 3.0 T in approximately 900 voxels. Spectral baselines were noticeably flatter at 3.0 T.
CONCLUSION: Expected gains in SNR and spectral resolution were not fully realized in a realistic experiment because of intrinsic and controllable factors. However, the 2346% improvements obtained enable more reliable peak-area estimation and an 1H-MRS acquisition approximately 50% shorter at 3.0 versus 1.5 T.
This article has been cited by other articles:
![]() |
K. J. Chang, I. R. Kamel, K. J. Macura, and D. A. Bluemke 3.0-T MR Imaging of the Abdomen: Comparison with 1.5 T RadioGraphics, November 1, 2008; 28(7): 1983 - 1998. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. F. Faria, S. M. Goldman, J. Szejnfeld, H. Melo, C. Kater, P. Kenney, M. P. Huayllas, G. Demarchi, V. V. Francisco, C. Andreoni, et al. Adrenal Masses: Characterization with in Vivo Proton MR Spectroscopy Initial Experience Radiology, December 1, 2007; 245(3): 788 - 797. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.P. Wattjes, M. Harzheim, G.G. Lutterbey, L. Klotz, H.H. Schild, and F. Traber Axonal Damage But No Increased Glial Cell Activity in the Normal-Appearing White Matter of Patients with Clinically Isolated Syndromes Suggestive of Multiple Sclerosis Using High-Field Magnetic Resonance Spectroscopy AJNR Am. J. Neuroradiol., September 1, 2007; 28(8): 1517 - 1522. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. M. Fayad, P. B. Barker, M. A. Jacobs, J. Eng, K. L. Weber, P. Kulesza, and D. A. Bluemke Characterization of Musculoskeletal Lesions on 3-T Proton MR Spectroscopy Am. J. Roentgenol., June 1, 2007; 188(6): 1513 - 1520. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-h. Kim, K.-H. Chang, D.G. Na, I.C. Song, B.J. Kwon, M.H. Han, and K. Kim 3T 1H-MR Spectroscopy in Grading of Cerebral Gliomas: Comparison of Short and Intermediate Echo Time Sequences AJNR Am. J. Neuroradiol., August 1, 2006; 27(7): 1412 - 1418. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Inglese, M. Spindler, J.S. Babb, P. Sunenshine, M. Law, and O. Gonen Field, Coil, and Echo-Time Influence on Sensitivity and Reproducibility of Brain Proton MR Spectroscopy AJNR Am. J. Neuroradiol., March 1, 2006; 27(3): 684 - 688. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. L. Chao, N. Schuff, J. H. Kramer, A. T. Du, A. A. Capizzano, J. O'Neill, O. M. Wolkowitz, W. J. Jagust, H. C. Chui, B. L. Miller, et al. Reduced medial temporal lobe N-acetylaspartate in cognitively impaired but nondemented patients Neurology, January 25, 2005; 64(2): 282 - 289. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. E. Warren NMR Spectroscopy and Pediatric Brain Tumors Oncologist, June 1, 2004; 9(3): 312 - 318. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. S. Ross The High-Field-Strength Curmudgeon AJNR Am. J. Neuroradiol., February 1, 2004; 25(2): 168 - 169. [Full Text] [PDF] |
||||
![]() |
O. Gonen Higher Field Strength for Proton MR Spectroscopy AJNR Am. J. Neuroradiol., May 1, 2003; 24(5): 781 - 782. [Full Text] [PDF] |
||||
![]() |
K. Kantarci, G. Reynolds, R. C. Petersen, B. F. Boeve, D. S. Knopman, S. D. Edland, G. E. Smith, R. J. Ivnik, E. G. Tangalos, and C. R. Jack Jr Proton MR Spectroscopy in Mild Cognitive Impairment and Alzheimer Disease: Comparison of 1.5 and 3 T AJNR Am. J. Neuroradiol., May 1, 2003; 24(5): 843 - 849. [Abstract] [Full Text] [PDF] |
||||