American Journal of Neuroradiology 23:762-767, May 2002
© 2002 American Society of Neuroradiology
INTERVENTIONAL
Evaluation of the Stability of Aneurysms after Embolization Using Detachable Coils: Correlation between Stability of Aneurysms and Embolized Volume of Aneurysms
a From the Department of Neurosurgery, Brain Research Institute, Niigata University, Niigata, Japan
Address reprint requests to Shinichi Tamatani, MD, Department of Neurosurgery, Brain Research Institute, Niigata University, 1757, Asahimachi, Niigata, 951-8585 Japan
BACKGROUND AND PURPOSE: The long-term outcome of aneurysmal coil embolization has not been determined. We retrospectively analyzed the results of our cases treated with detachable coils and evaluated the long-term stability of embolized aneurysms.
METHODS: This study involved 100 aneurysms in 93 patients who underwent follow-up angiography
3 months after initial treatment between December 1993 and December 1999. The percentage of the coil volume occupying the aneurysm lumen (embolized volume) was used as an index to evaluate the stability of embolized aneurysms. The reliability of the embolized volume was also evaluated by comparing angiographic percentage occlusion.
RESULTS: Follow-up angiographic assessment was conducted 12 ± 8.5 months after initial treatment. Angiographic evaluation of percentage occlusion at initial treatment did not always predict long-term stability of embolized aneurysms. Of 49 aneurysms judged as being totally occluded at initial treatment, 44 remained unchanged and five showed recanalization. The embolized volume of unchanged aneurysms was 30.8 ± 10.2%, and that of recanalized aneurysms was 19.9 ± 10.6%. There was a significant difference between these two groups (P=.03). Of 29 subtotally occluded aneurysms, nine had further thrombosis (embolized volume = 31.8 ± 12.7%), nine remained unchanged (embolized volume = 23.2 ± 10.3%), and 11 had recanalization (embolized volume = 14.1 ± 6.1%). The mean embolized volume of 11 recanalized aneurysms was significantly lower than in the thrombosed group and the unchanged group (P=.002 and P < .001, respectively). Large aneurysms tended to have recanalization more frequently (59%) than did small aneurysms (15%).
CONCLUSION: There is a significant correlation between embolized volume and stability of embolized aneurysms. Embolized volume is a more objective index than is subjectively angiographic percentage occlusion. In addition to angiographic assessment, measurement of embolized volume could be useful to predict angiographic changes of aneurysms.
This article has been cited by other articles:
![]() |
J.-F. Vendrell, N. Menjot, V. Costalat, D. Hoa, J. Moritz, H. Brunel, and A. Bonafe Endovascular Treatment of 174 Middle Cerebral Artery Aneurysms: Clinical Outcome and Radiologic Results at Long-term Follow-up Radiology, October 1, 2009; 253(1): 191 - 198. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Linfante, M.J. DeLeo III, M.J. Gounis, C.S. Brooks, and A.K. Wakhloo Cerecyte versus Platinum Coils in the Treatment of Intracranial Aneurysms: Packing Attenuation and Clinical and Angiographic Midterm Results AJNR Am. J. Neuroradiol., September 1, 2009; 30(8): 1496 - 1501. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. P. Ferns, M. E.S. Sprengers, W. J. van Rooij, G. J.E. Rinkel, J. C. van Rijn, S. Bipat, M. Sluzewski, and C. B.L.M. Majoie Coiling of Intracranial Aneurysms: A Systematic Review on Initial Occlusion and Reopening and Retreatment Rates Stroke, August 1, 2009; 40(8): e523 - e529. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Sherif, G. Bavinzski, C. Dorfer, F. Kanz, E. Schuster, and H. Plenk Jr Computerized Assessment of Angiographic Occlusion Rate and Coil Density in Embolized Human Cerebral Aneurysms AJNR Am. J. Neuroradiol., May 1, 2009; 30(5): 1046 - 1053. [Abstract] [Full Text] [PDF] |
||||
![]() |
S.A. Renowden, P. Koumellis, V. Benes, W. Mukonoweshuro, A.J. Molyneux, and N.S. McConachie Retreatment of Previously Embolized Cerebral Aneurysms: The Risk of Further Coil Embolization Does Not Negate the Advantage of the Initial Embolization AJNR Am. J. Neuroradiol., August 1, 2008; 29(7): 1401 - 1404. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Pierot, X. Leclerc, A. Bonafe, S. Bracard, and for the French Matrix Registry Investigators Endovascular Treatment of Intracranial Aneurysms with Matrix Detachable Coils: Midterm Anatomic Follow-Up from a Prospective Multicenter Registry AJNR Am. J. Neuroradiol., January 1, 2008; 29(1): 57 - 61. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y.H. Ding, D. Dai, R. Kadirvel, D.A. Lewis, H.J. Cloft, and D.F. Kallmes Relationship Between Aneurysm Volume and Histologic Healing after Coil Embolization in Elastase-Induced Aneurysms: A Retrospective Study AJNR Am. J. Neuroradiol., January 1, 2008; 29(1): 98 - 101. [Abstract] [Full Text] [PDF] |
||||
![]() |
A.K. Wakhloo, M.J. Gounis, J.S. Sandhu, N. Akkawi, A.E. Schenck, and I. Linfante Complex-Shaped Platinum Coils for Brain Aneurysms: Higher Packing Density, Improved Biomechanical Stability, and Midterm Angiographic Outcome AJNR Am. J. Neuroradiol., August 1, 2007; 28(7): 1395 - 1400. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Piotin, L. Spelle, C. Mounayer, M. T. Salles-Rezende, D. Giansante-Abud, R. Vanzin-Santos, and J. Moret Intracranial Aneurysms: Treatment with Bare Platinum Coils--Aneurysm Packing, Complex Coils, and Angiographic Recurrence Radiology, May 1, 2007; 243(2): 500 - 508. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Campi, N. Ramzi, A. J. Molyneux, P. E. Summers, R. S.C. Kerr, M. Sneade, J. A. Yarnold, J. Rischmiller, and J. V. Byrne Retreatment of Ruptured Cerebral Aneurysms in Patients Randomized by Coiling or Clipping in the International Subarachnoid Aneurysm Trial (ISAT) Stroke, May 1, 2007; 38(5): 1538 - 1544. [Abstract] [Full Text] [PDF] |
||||
![]() |
H.J. Cloft and for the HEAL Investigators HydroCoil for Endovascular Aneurysm Occlusion (HEAL) Study: 3-6 Month Angiographic Follow-Up Results AJNR Am. J. Neuroradiol., January 1, 2007; 28(1): 152 - 154. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Berenstein, J.K. Song, Y. Niimi, K. Namba, N.S. Heran, J.L. Brisman, M.C. Nahoum, M. Madrid, D.J. Langer, and M.J. Kupersmith Treatment of Cerebral Aneurysms with Hydrogel-Coated Platinum Coils (HydroCoil): Early Single-Center Experience. AJNR Am. J. Neuroradiol., October 1, 2006; 27(9): 1834 - 1840. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Gaba, S. A. Ansari, S. S. Roy, F. A. Marden, M. A.G. Viana, and T. W. Malisch Embolization of Intracranial Aneurysms With Hydrogel-Coated Coils Versus Inert Platinum Coils: Effects on Packing Density, Coil Length and Quantity, Procedure Performance, Cost, Length of Hospital Stay, and Durability of Therapy Stroke, June 1, 2006; 37(6): 1443 - 1450. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Piotin, B. Daghman, C. Mounayer, L. Spelle, and J. Moret Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms. AJNR Am. J. Neuroradiol., April 1, 2006; 27(4): 839 - 842. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Niimi, J. Song, M. Madrid, and A. Berenstein Endosaccular Treatment of Intracranial Aneurysms Using Matrix Coils: Early Experience and Midterm Follow-Up Stroke, April 1, 2006; 37(4): 1028 - 1032. [Abstract] [Full Text] [PDF] |
||||
![]() |
H.J. Cloft and for the HEAL Investigators HydroCoil for Endovascular Aneurysm Occlusion (HEAL) Study: Periprocedural Results. AJNR Am. J. Neuroradiol., February 1, 2006; 27(2): 289 - 292. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. O. Bescos, M. J. Slob, C. H. Slump, M. Sluzewski, and W. J. van Rooij Volume Measurement of Intracranial Aneurysms from 3D Rotational Angiography: Improvement of Accuracy by Gradient Edge Detection AJNR Am. J. Neuroradiol., November 1, 2005; 26(10): 2569 - 2572. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Iijima, M. Piotin, C. Mounayer, L. Spelle, A. Weill, and J. Moret Endovascular Treatment with Coils of 149 Middle Cerebral Artery Berry Aneurysms Radiology, November 1, 2005; 237(2): 611 - 619. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. A. Taschner, X. Leclerc, H. Rachdi, A. M. Barros, and J.-P. Pruvo Matrix Detachable Coils for the Endovascular Treatment of Intracranial Aneurysms: Analysis of Early Angiographic and Clinical Outcomes Stroke, October 1, 2005; 36(10): 2176 - 2180. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. K. Goddard, C. J. Moran, D. T. Cross III, and C. P. Derdeyn Absent Relationship between the Coil-Embolization Ratio in Small Aneurysms Treated with a Single Detachable Coil and Outcomes AJNR Am. J. Neuroradiol., September 1, 2005; 26(8): 1916 - 1920. [Abstract] [Full Text] [PDF] |
||||
![]() |
H.-S. Kang, M. H. Han, B. J. Kwon, O-K. Kwon, S. H. Kim, S. H. Choi, and K.-H. Chang Short-Term Outcome of Intracranial Aneurysms Treated with Polyglycolic Acid/Lactide Copolymer-Coated Coils Compared to Historical Controls Treated with Bare Platinum Coils: A Single-Center Experience AJNR Am. J. Neuroradiol., September 1, 2005; 26(8): 1921 - 1928. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Gallas, A. Pasco, J.-P. Cottier, J. Gabrillargues, J. Drouineau, C. Cognard, and D. Herbreteau A Multicenter Study of 705 Ruptured Intracranial Aneurysms Treated with Guglielmi Detachable Coils AJNR Am. J. Neuroradiol., August 1, 2005; 26(7): 1723 - 1731. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Lubicz, X. Leclerc, J.-Y. Gauvrit, J.-P. Lejeune, and J.-P. Pruvo Three-Dimensional Packing with Complex Orbit Coils for the Endovascular Treatment of Intracranial Aneurysms AJNR Am. J. Neuroradiol., June 1, 2005; 26(6): 1342 - 1348. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Slob, W. J. van Rooij, and M. Sluzewski Coil Thickness and Packing of Cerebral Aneurysms: A Comparative Study of Two Types of Coils AJNR Am. J. Neuroradiol., April 1, 2005; 26(4): 901 - 903. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Lubicz, X. Leclerc, J.-Y. Gauvrit, J.-P. Lejeune, and J.-P. Pruvo Endovascular Treatment of Intracranial Aneurysms with Matrix Coils: A Preliminary Study of Immediate Post-treatment Results AJNR Am. J. Neuroradiol., February 1, 2005; 26(2): 373 - 375. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Sluzewski, W. J. van Rooij, M. J. Slob, J. O. Bescos, C. H. Slump, and D. Wijnalda Relation between Aneurysm Volume, Packing, and Compaction in 145 Cerebral Aneurysms Treated with Coils Radiology, June 1, 2004; 231(3): 653 - 658. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-N. Vallee, L. Pierot, A. Bonafe, F. Turjman, P. Flandroy, J. Berge, G. Rodesch, and S. Bracard Endovascular Treatment of Intracranial Wide-Necked Aneurysms Using Three-Dimensional Coils: Predictors of Immediate Anatomic and Clinical Results AJNR Am. J. Neuroradiol., February 1, 2004; 25(2): 298 - 306. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. J. Cloft and D. F. Kallmes Aneurysm Packing with HydroCoil Embolic System versus Platinum Coils: Initial Clinical Experience AJNR Am. J. Neuroradiol., January 1, 2004; 25(1): 60 - 62. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Piotin, A. Iijima, H. Wada, and J. Moret Increasing the Packing of Small Aneurysms with Complex-Shaped Coils: An In Vitro Study AJNR Am. J. Neuroradiol., August 1, 2003; 24(7): 1446 - 1448. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Raymond, F. Guilbert, A. Weill, S. A. Georganos, L. Juravsky, A. Lambert, J. Lamoureux, M. Chagnon, and D. Roy Long-Term Angiographic Recurrences After Selective Endovascular Treatment of Aneurysms With Detachable Coils Stroke, June 1, 2003; 34(6): 1398 - 1403. [Abstract] [Full Text] [PDF] |
||||


