AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sugahara, T.
Right arrow Articles by Takahashi, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sugahara, T.
Right arrow Articles by Takahashi, M.

BRAIN

Comparison of 2D and 3D Digital Subtraction Angiography in Evaluation of Intracranial Aneurysms

Takeshi Sugaharaa, Yukunori Korogib, Kouji Nakashimaa, Satoshi Hamatakea, Shin Hondaa and Mutsumasa Takahashib

a Departments of Radiology, Health and Welfare Hospital, Kumamoto, Japan
b the Kumamoto University School of Medicine, Kumamoto, Japan

Address reprint requests to Takeshi Sugahara, MD, Department of Radiology, Kumamoto University School of Medicine, Honjo, Kumamoto, 860-8556, Japan

BACKGROUND AND PURPOSE: Although digital subtraction angiography (DSA) is considered the criterion standard for depiction of intracranial aneurysms, it is often difficult to determine the relationship of overlapping vessels to aneurysms when using 2D DSA. We compared 2D and 3D DSA in evaluation of intracranial aneurysms.

METHODS: Thirty-six consecutive patients with cerebral aneurysms underwent 2D and 3D DSA. After standard 2D DSA, rotational DSA was performed. Maximum intensity projection (MIP) and shaded surface display (SSD) images were created from the rotational DSA data sets. All images were assessed randomly for overall image quality, presence of aneurysm, presence of aneurysmal lobulation, visualization of aneurysmal neck, and relationship to adjacent vessels. Data analysis was conducted for 40 aneurysms treated by clip placement.

RESULTS: One aneurysm that was not detected at 2D DSA was classified as uncertain on the basis of rotational DSA. All aneurysms were classified as probably or definitively present on the basis of MIP and SSD findings. Overall image quality of rotational DSA, MIP, and SSD was statistically inferior to that of the standard 2D DSA for visualization of distal arteries. However, MIP and SSD images were significantly superior to those of standard 2D DSA for all other evaluations. For detection of lobulation, SSD images were significantly superior to other images, and for visualization of aneurysmal neck and relationship to neighboring arteries, SSD images were significantly superior to those of rotational DSA. For evaluation of the relationship to neighboring arteries, MIP images were significantly superior to those of rotational DSA.

CONCLUSION: Three-dimensional DSA, especially SSD, provided more detailed information for evaluating cerebral aneurysms than did standard 2D and rotational DSA.




This article has been cited by other articles:


Home page
StrokeHome page
M.-H. Li, Y.-S. Cheng, Y.-D. Li, C. Fang, S.-W. Chen, W. Wang, D.-J. Hu, and H.-W. Xu
Large-Cohort Comparison Between Three-Dimensional Time-of-Flight Magnetic Resonance and Rotational Digital Subtraction Angiographies in Intracranial Aneurysm Detection
Stroke, September 1, 2009; 40(9): 3127 - 3129.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
W. Brinjikji, H. Cloft, G. Lanzino, and D.F. Kallmes
Comparison of 2D Digital Subtraction Angiography and 3D Rotational Angiography in the Evaluation of Dome-to-Neck Ratio
AJNR Am. J. Neuroradiol., April 1, 2009; 30(4): 831 - 834.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
T. Hiu, N. Kitagawa, M. Morikawa, K. Hayashi, N. Horie, Y. Morofuji, K. Suyama, and I. Nagata
Efficacy of DynaCT Digital Angiography in the Detection of the Fistulous Point of Dural Arteriovenous Fistulas
AJNR Am. J. Neuroradiol., March 1, 2009; 30(3): 487 - 491.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J.B. White, C.G.M. Ken, H.J. Cloft, and D.F. Kallmes
Coils in a Nutshell: A Review of Coil Physical Properties
AJNR Am. J. Neuroradiol., August 1, 2008; 29(7): 1242 - 1246.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
W.J. van Rooij, M.E. Sprengers, A.N. de Gast, J.P.P. Peluso, and M. Sluzewski
3D Rotational Angiography: The New Gold Standard in the Detection of Additional Intracranial Aneurysms
AJNR Am. J. Neuroradiol., May 1, 2008; 29(5): 976 - 979.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
W.J. van Rooij, J.P.P. Peluso, M. Sluzewski, and G.N. Beute
Additional Value of 3D Rotational Angiography in Angiographically Negative Aneurysmal Subarachnoid Hemorrhage: How Negative Is Negative?
AJNR Am. J. Neuroradiol., May 1, 2008; 29(5): 962 - 966.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A.M. McKinney, C.S. Palmer, C.L. Truwit, A. Karagulle, and M. Teksam
Detection of Aneurysms by 64-Section Multidetector CT Angiography in Patients Acutely Suspected of Having an Intracranial Aneurysm and Comparison with Digital Subtraction and 3D Rotational Angiography
AJNR Am. J. Neuroradiol., March 1, 2008; 29(3): 594 - 602.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. M. McKinney, C. L. Truwit, C. S. Palmer, M. Teksam, K. Papke, C. K. Kuhl, M. Fruth, C. Haupt, M. Schlunz-Hendann, D. Sauner, et al.
Intracranial Aneurysms: Is the Diagnostic Accuracy Rate of Multidetector CT Angiography Equivalent to That of Three-dimensional Rotational Conventional Angiography?
Radiology, March 1, 2008; 246(3): 982 - 984.
[Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A.N. de Gast, W.J. van Rooij, and M. Sluzewski
Fenestrations of the Anterior Communicating Artery: Incidence on 3D Angiography and Relationship to Aneurysms
AJNR Am. J. Neuroradiol., February 1, 2008; 29(2): 296 - 298.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Romijn, H.A.F. G. van Andel, M.A. van Walderveen, M.E. Sprengers, J.C. van Rijn, W.J. van Rooij, H.W. Venema, C.A. Grimbergen, G.J. den Heeten, and C.B. Majoie
Diagnostic Accuracy of CT Angiography with Matched Mask Bone Elimination for Detection of Intracranial Aneurysms: Comparison with Digital Subtraction Angiography and 3D Rotational Angiography
AJNR Am. J. Neuroradiol., January 1, 2008; 29(1): 134 - 139.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
R.C. Wallace, J.P. Karis, S. Partovi, and D. Fiorella
Noninvasive Imaging of Treated Cerebral Aneurysms, Part I: MR Angiographic Follow-Up of Coiled Aneurysms
AJNR Am. J. Neuroradiol., June 1, 2007; 28(6): 1001 - 1008.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
S. Kakeda, Y. Korogi, N. Ohnari, Y. Hatakeyama, J. Moriya, N. Oda, K. Nishino, and W. Miyamoto
3D Digital Subtraction Angiography of Intracranial Aneurysms: Comparison of Flat Panel Detector with Conventional Image Intensifier TV System Using a Vascular Phantom
AJNR Am. J. Neuroradiol., May 1, 2007; 28(5): 839 - 843.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
D.Y. Yoon, K.J. Lim, C.S. Choi, B.M. Cho, S.M. Oh, and S.K. Chang
Detection and Characterization of Intracranial Aneurysms with 16-Channel Multidetector Row CT Angiography: A Prospective Comparison of Volume-Rendered Images and Digital Subtraction Angiography
AJNR Am. J. Neuroradiol., January 1, 2007; 28(1): 60 - 67.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
I. M. Burger, K. J. Murphy, L. C. Jordan, R. J. Tamargo, and P. Gailloud
Safety of Cerebral Digital Subtraction Angiography in Children: Complication Rate Analysis in 241 Consecutive Diagnostic Angiograms
Stroke, October 1, 2006; 37(10): 2535 - 2539.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Piotin, B. Daghman, C. Mounayer, L. Spelle, and J. Moret
Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms.
AJNR Am. J. Neuroradiol., April 1, 2006; 27(4): 839 - 842.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
V. Costalat, E. Lebars, L. Sarry, A. Defasque, E. Barbotte, H. Brunel, G. Bourbotte, and A. Bonafe
In Vitro Evaluation of 2D-Digital Subtraction Angiography versus 3D-Time-of-Flight in Assessment of Intracranial Cerebral Aneurysm Filling after Endovascular Therapy
AJNR Am. J. Neuroradiol., January 1, 2006; 27(1): 177 - 184.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. M. Racadio, B. L. Fricke, B. V. Jones, and L. F. Donnelly
Three-Dimensional Rotational Angiography of Neurovascular Lesions in Pediatric Patients
Am. J. Roentgenol., January 1, 2006; 186(1): 75 - 84.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
B. A. Schueler, D. F. Kallmes, and H. J. Cloft
3D Cerebral Angiography: Radiation Dose Comparison with Digital Subtraction Angiography
AJNR Am. J. Neuroradiol., September 1, 2005; 26(8): 1898 - 1901.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
P. Gailloud, S. Oishi, and K. Murphy
Three-Dimensional Fusion Digital Subtraction Angiography: New Reconstruction Algorithm for Simultaneous Three-Dimensional Rendering of Osseous and Vascular Information Obtained during Rotational Angiography
AJNR Am. J. Neuroradiol., April 1, 2005; 26(4): 908 - 911.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
H.-S. Kang, M. H. Han, B. J. Kwon, O-K. Kwon, S. H. Kim, and K.-H. Chang
Evaluation of the Lenticulostriate Arteries with Rotational Angiography and 3D Reconstruction
AJNR Am. J. Neuroradiol., February 1, 2005; 26(2): 306 - 312.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J. K. Song, Y. Niimi, J. L. Brisman, and A. Berenstein
Simultaneous Bilateral Internal Carotid Artery 3D Rotational Angiography
AJNR Am. J. Neuroradiol., November 1, 2004; 25(10): 1787 - 1789.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
H.-S. Kang, M. H. Han, B. J. Kwon, S. I. Jung, C.-W. Oh, D. H. Han, and K.-H. Chang
Postoperative 3D Angiography in Intracranial Aneurysms
AJNR Am. J. Neuroradiol., October 1, 2004; 25(9): 1463 - 1469.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Hirai, Y. Korogi, K. Ono, M. Yamura, S. Uemura, and Y. Yamashita
Pseudostenosis Phenomenon at Volume-rendered Three-dimensional Digital Angiography of Intracranial Arteries: Frequency, Location, and Effect on Image Evaluation
Radiology, September 1, 2004; 232(3): 882 - 887.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
P. Gailloud, S. Oishi, J. Carpenter, and K. J. Murphy
Three-Dimensional Digital Angiography: New Tool for Simultaneous Three-Dimensional Rendering of Vascular and Osseous Information during Rotational Angiography
AJNR Am. J. Neuroradiol., April 1, 2004; 25(4): 571 - 573.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
S. Shimizu, H. Suzuki, H. Maki, M. Maeda, F. Miya, K. Benali, Y. Trousset, and W. Taki
A Novel Image Fusion Visualizes the Angioarchitecture of the Perforating Arteries in the Brain
AJNR Am. J. Neuroradiol., November 1, 2003; 24(10): 2011 - 2014.
[Abstract] [Full Text] [PDF]