American Journal of Neuroradiology 24:2035-2038, November-December 2003
© 2003 American Society of Neuroradiology
INTERVENTIONAL
Thromboembolic Events Associated with Guglielmi Detachable Coil Embolization with Use of Diffusion-Weighted MR Imaging. Part II. Detection of the Microemboli Proximal to Cerebral Aneurysm
a Department of Neurosurgery, National Cardiovascular Center, Osaka, Japan
b Department of Radiology, National Cardiovascular Center, Osaka, Japan
Address correspondence to Akio Soeda, MD, Department of Neurosurgery, Gifu University School of Medicine, 40 Tsukasa-machi, Gifu City, Gifu 500-8075, Japan
BACKGROUND AND PURPOSE: The purpose of this study was to document the incidence and radiologic appearance of thromboembolic events during Guglielmi detachable coil (GDC) embolization for asymptomatic basilar artery (BA) bifurcation and BA-superior cerebellar artery (SCA) aneurysms by using diffusion-weighted (DW) MR imaging, with special emphasis on the evidence of thromboembolic events in vascular territories proximal from the treated aneurysm, which cause cerebellar infarction, and to discuss which step of the procedure (aneurysm or catheter manipulation) may play a role for most thromboembolic events.
METHODS: Since 1999, 38 asymptomatic BA bifurcation and BA-SCA aneurysms were treated with GDCs at the National Cardiovascular Center. DW studies were performed for 26 patients between 2 and 5 days after GDC embolizations. All DW images were reviewed by two radiologists for depiction of abnormalities. These findings were retrospectively evaluated with clinical and technical factors of thromboembolic events.
RESULTS: DW images showed new hyperintense lesions in 18 patients (69%), with seven (27%) incurring neurologic deteriorations. All symptomatic patients fully recovered by discharge. Fourteen (78%) of 18 patients showed new lesions proximal to the treated aneurysm; that is, in the cerebellar hemispheres. In three cases treated with the balloon-assisted technique, new hyperintense lesions were seen.
CONCLUSION: In our experience, most thromboembolic events related to the use of the GDC embolization may be caused by catheter manipulation, especially in the case of the balloon-assisted technique. Caution should be exercised in the handling of catheters. Furthermore, a softer and smaller caliber catheter and simple GDC technique should be considered.
This article has been cited by other articles:
![]() |
N. Krayenbuhl, E. Erdem, M. Oinas, and A. F. Krisht Symptomatic and Silent Ischemia Associated With Microsurgical Clipping of Intracranial Aneurysms: Evaluation With Diffusion-Weighted MRI Stroke, January 1, 2009; 40(1): 129 - 133. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.L. Brisman, M. Jilani, and J.S. McKinney Contrast Enhancement Hyperdensity After Endovascular Coiling of Intracranial Aneurysms AJNR Am. J. Neuroradiol., March 1, 2008; 29(3): 588 - 593. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Ozturk, I. Saatci, A.G. Pamuk, C. Erdogan, I. Akmangit, S. Geyik, and H.S. Cekirge Focal Increased Cortical Density in Immediate Postembolization CT Scans of Patients with Intracranial Aneurysms. AJNR Am. J. Neuroradiol., October 1, 2006; 27(9): 1866 - 1875. [Abstract] [Full Text] [PDF] |
||||
![]() |
W.J. van Rooij, M. Sluzewski, G.N. Beute, and P.C. Nijssen Procedural Complications of Coiling of Ruptured Intracranial Aneurysms: Incidence and Risk Factors in a Consecutive Series of 681 Patients AJNR Am. J. Neuroradiol., August 1, 2006; 27(7): 1498 - 1501. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Cronqvist, R. Wirestam, B. Ramgren, L. Brandt, B. Romner, O. Nilsson, H. Saveland, S. Holtas, and E.-M. Larsson Endovascular Treatment of Intracerebral Arteriovenous Malformations: Procedural Safety, Complications, and Results Evaluated by MR Imaging, Including Diffusion and Perfusion Imaging AJNR Am. J. Neuroradiol., January 1, 2006; 27(1): 162 - 176. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Tsumoto, T. Terada, M. Tsuura, H. Matsumoto, O. Masuo, H. Yamaga, and T. Itakura Diffusion-Weighted Imaging Abnormalities after Percutaneous Transluminal Angioplasty and Stenting for Intracranial Atherosclerotic Disease AJNR Am. J. Neuroradiol., February 1, 2005; 26(2): 385 - 389. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Albayram, H. Selcuk, B. Kara, E. Bozdag, O. Uzma, N. Kocer, and C. Islak Thromboembolic Events Associated with Balloon-Assisted Coil Embolization: Evaluation with Diffusion-Weighted MR Imaging AJNR Am. J. Neuroradiol., November 1, 2004; 25(10): 1768 - 1777. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Biondi, A. Soeda, N. Sakai, K. Iihara, and I. Nagata Diffusion-Weighted Imaging of Thromboembolic Events Associated with Coil Embolization of Intracranial Aneurysms AJNR Am. J. Neuroradiol., November 1, 2004; 25(10): 1861 - 1862. [Full Text] [PDF] |
||||
![]() |
S. Albayram, D. Selcuk, A. Soeda, N. Sakai, K. Iihara, and I. Nagata Thromboembolic Events Associated with Guglielmi Detachable Coil Embolization of Asymptomatic Cerebral Aneurysms: Evaluation of 66 Consecutive Cases with Use of Diffusion-Weighted MR Imaging AJNR Am. J. Neuroradiol., January 1, 2004; 25(1): 159 - 160. [Full Text] [PDF] |
||||