AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ernemann, U. U.
Right arrow Articles by Skalej, M. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ernemann, U. U.
Right arrow Articles by Skalej, M. D.

INTERVENTIONAL

Influence of Geometric and Hemodynamic Parameters on Aneurysm Visualization during Three-Dimensional Rotational Angiography: An in Vitro Study

Ulrike U. Ernemanna, Eckart Grönewällera, Frank B. Duffnerb, Oezlem Guervita, Joerg Claassena and Martin D. Skaleja

a Department of Neuroradiology, University Hospital Tuebingen, Germany
b Department of Neurosurgery, University Hospital Tuebingen, Germany

Address reprint requests to Dr med Ulrike Ernemann, Department of Neuroradiology, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, 72076 Tuebingen, Germany

BACKGROUND AND PURPOSE: Aneurysm depiction with three-dimensional (3D) rotational angiography is influenced by investigator-defined parameters such as image acquisition and contrast agent injection and by the hemodynamic pattern in the parent artery and aneurysm. To assess the impact of the geometric configuration of parent artery and aneurysm on the 3D visualization of saccular aneurysms, we studied silicone aneurysm models under pulsatile-flow conditions.

METHODS: Rotational angiography was performed in three bifurcation and three lateral aneurysm models with ostia of different widths. Three acquisition modalities (5, 8, and 14 seconds in duration, acquisition rate of 10 frames per second) and two techniques for the injection of contrast material (continuous flow and injection with an initial bolus) were applied. 3D reconstructions were obtained with a volume-rendering technique.

RESULTS: Bifurcation aneurysms were visualized with high accuracy. Filling deficits distant to the inflow zone could be compensated for with the bolus-injection technique, and complete depiction of aneurysm shape was achieved in the 8-second rotation with 20 mL of contrast agent. In lateral aneurysms, the accuracy of 3D reconstructions depended on the width of the ostium. Although rotational studies in wide-necked lateral aneurysms yielded adequate reconstructions, 3D visualization of small-necked aneurysms was incomplete with the preferential depiction of the distal shell, which represents the inflow zone into the aneurysmal lumen.

CONCLUSION: Contrast agent injection with the initial-bolus technique improved the depiction of aneurysms, compared with the continuous-flow method. Reconstructions of rotational studies of narrow-necked lateral aneurysms yielded incomplete visualization of the aneurysm.




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
L.-D. Jou, A. Mohamed, D.H. Lee, and M.E. Mawad
3D Rotational Digital Subtraction Angiography May Underestimate Intracranial Aneurysms: Findings from Two Basilar Aneurysms
AJNR Am. J. Neuroradiol., October 1, 2007; 28(9): 1690 - 1692.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M. Piotin, B. Daghman, C. Mounayer, L. Spelle, and J. Moret
Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms.
AJNR Am. J. Neuroradiol., April 1, 2006; 27(4): 839 - 842.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J. K. Song, Y. Niimi, J. L. Brisman, and A. Berenstein
Simultaneous Bilateral Internal Carotid Artery 3D Rotational Angiography
AJNR Am. J. Neuroradiol., November 1, 2004; 25(10): 1787 - 1789.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Hirai, Y. Korogi, K. Ono, M. Yamura, S. Uemura, and Y. Yamashita
Pseudostenosis Phenomenon at Volume-rendered Three-dimensional Digital Angiography of Intracranial Arteries: Frequency, Location, and Effect on Image Evaluation
Radiology, September 1, 2004; 232(3): 882 - 887.
[Abstract] [Full Text] [PDF]