BACKGROUND AND PURPOSE: Contrast-enhanced MR angiography and extracranial color-coded duplex sonography are noninvasive, preoperative imaging modalities for evaluation of carotid artery stenosis. Innovative techniques and improvements in image quality require frequent reassessment of accuracy, reliability, and diagnostic value compared with those of digital subtraction angiography (DSA). We evaluated contrast-enhanced MR angiography and duplex sonography compared with DSA for detection of high-grade carotid artery stenoses.
METHODS: Four readers, blinded to clinical symptoms and the outcome of other studies, independently evaluated stenoses on contrast-enhanced MR angiograms in 71 vessels of 39 symptomatic patients. Duplex sonography was also performed in all vessels. The severity of stenosis was defined according to North American Symptomatic Carotid Endarterectomy Trial criteria (029%, 3069%, 7099%, 100%). Results of both modalities were compared with the corresponding DSA findings.
RESULTS: Contrast-enhanced MR angiography had a sensitivity and specificity of 94.9% and 79.1%, respectively, for the identification of carotid artery stenoses of 70% or greater. Sensitivity and specificity of duplex sonography were 92.9% and 81.9%, respectively. Combining data from both tests revealed a sensitivity and specificity of 100% and 81.4%, respectively, for concordant results (80% of vessels).
CONCLUSION: Concordant results of contrast-enhanced MR angiography and duplex sonography increase the diagnostic sensitivity to 100%. The reliability of MR angiography is comparable to that of DSA. The combination of contrast-enhanced MR angiography and duplex sonography might be preferable over DSA for preoperative evaluation in most patients, thus reducing the risk of perioperative morbidity and improving the overall outcome.
This article has been cited by other articles:
![]() |
M. Anzidei, A. Napoli, B. C. Marincola, I. Nofroni, D. Geiger, F. Zaccagna, C. Catalano, and R. Passariello Gadofosveset-enhanced MR Angiography of Carotid Arteries: Does Steady-State Imaging Improve Accuracy of First-Pass Imaging? Comparison with Selective Digital Subtraction Angiography Radiology, May 1, 2009; 251(2): 457 - 466. [Abstract] [Full Text] [PDF] |
||||
![]() |
L.S. Babiarz, J.M. Romero, E.K. Murphy, B. Brobeck, P.W. Schaefer, R.G. Gonzalez, and M.H. Lev Contrast-Enhanced MR Angiography Is Not More Accurate Than Unenhanced 2D Time-of-Flight MR Angiography for Determining >=70% Internal Carotid Artery Stenosis AJNR Am. J. Neuroradiol., April 1, 2009; 30(4): 761 - 768. [Abstract] [Full Text] [PDF] |
||||
![]() |
R.P. Lim, M. Shapiro, E.Y. Wang, M. Law, J.S. Babb, L.E. Rueff, J.S. Jacob, S. Kim, R.H. Carson, T.P. Mulholland, et al. 3D Time-Resolved MR Angiography (MRA) of the Carotid Arteries with Time-Resolved Imaging with Stochastic Trajectories: Comparison with 3D Contrast-Enhanced Bolus-Chase MRA and 3D Time-Of-Flight MRA AJNR Am. J. Neuroradiol., November 1, 2008; 29(10): 1847 - 1854. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. M. Debrey, H. Yu, J. K. Lynch, K.-O. Lovblad, V. L. Wright, S.-J. D. Janket, and A. E. Baird Diagnostic Accuracy of Magnetic Resonance Angiography for Internal Carotid Artery Disease: A Systematic Review and Meta-Analysis Stroke, August 1, 2008; 39(8): 2237 - 2248. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Pedraza, Y. Silva, S. Remollo, J. Puig, A. Quiles, E. Gomez, M. Castellanos, J. Serena, and A. Davalos Response to Letter by Sohn et al Stroke, April 1, 2007; 38(4): 1134 - 1134. [Full Text] [PDF] |
||||
![]() |
O W Hamer, I Borisch, C Paetzel, W R Nitz, J Seitz, S Feuerbach, and N Zorger In vitro evaluation of stent patency and in-stent stenoses in 10 metallic stents using MR angiography Br. J. Radiol., August 1, 2006; 79(944): 636 - 643. [Abstract] [Full Text] [PDF] |
||||
![]() |
D Mitra, D Connolly, S Jenkins, P English, D Birchall, C Mandel, K Shrikanth, B Gregson, and A Gholkar Comparison of image quality, diagnostic confidence and interobserver variability in contrast enhanced MR angiography and 2D time of flight angiography in evaluation of carotid stenosis. Br. J. Radiol., March 1, 2006; 79(939): 201 - 207. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. W. Hamer, T. Finkenzeller, I. Borisch, C. Paetzel, N. Zorger, S. Feuerbach, and W. Nitz In Vivo Evaluation of Patency and In-Stent Stenoses After Implantation of Nitinol Stents in Iliac Arteries Using MR Angiography Am. J. Roentgenol., November 1, 2005; 185(5): 1282 - 1288. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Anzalone, F. Scomazzoni, R. Castellano, L. Strada, C. Righi, L. S. Politi, M. A. Kirchin, R. Chiesa, and G. Scotti Carotid Artery Stenosis: Intraindividual Correlations of 3D Time-of-Flight MR Angiography, Contrast-enhanced MR Angiography, Conventional DSA, and Rotational Angiography for Detection and Grading Radiology, July 1, 2005; 236(1): 204 - 213. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. M. Hathout, J. R. Fink, S. M. El-Saden, and E. G. Grant Sonographic NASCET Index: A New Doppler Parameter for Assessment of Internal Carotid Artery Stenosis AJNR Am. J. Neuroradiol., January 1, 2005; 26(1): 68 - 75. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. A. Willinek, M. von Falkenhausen, M. Born, J. Gieseke, T. Holler, T. Klockgether, H. J. Textor, H. H. Schild, and H. Urbach Noninvasive Detection of Steno-Occlusive Disease of the Supra-Aortic Arteries With Three-Dimensional Contrast-Enhanced Magnetic Resonance Angiography: A Prospective, Intra-Individual Comparative Analysis With Digital Subtraction Angiography Stroke, January 1, 2005; 36(1): 38 - 43. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Tola, M. Yurdakul, and T. Cumhur Combined Use of Color Duplex Ultrasonography and B-Flow Imaging for Evaluation of Patients with Carotid Artery Stenosis AJNR Am. J. Neuroradiol., November 1, 2004; 25(10): 1856 - 1860. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. U-King-Im, R. A. Trivedi, M. J. Graves, N. J. Higgins, J. J. Cross, B. D. Tom, W. Hollingworth, H. Eales, E. A. Warburton, P. J. Kirkpatrick, et al. Contrast-enhanced MR angiography for carotid disease: Diagnostic and potential clinical impact Neurology, April 27, 2004; 62(8): 1282 - 1290. [Abstract] [Full Text] [PDF] |
||||