AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kudo, K.
Right arrow Articles by Miyasaka, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kudo, K.
Right arrow Articles by Miyasaka, K.

BRAIN

Physiologic Change in Flow Velocity and Direction of Dural Venous Sinuses with Respiration: MR Venography and Flow Analysis

Kohsuke Kudoa, Satoshi Teraea, Aki Ishiib, Tokuhiko Omatsub, Takeshi Asanoa, KhinKhin Thaa and Kazuo Miyasakaa

a Department of Radiology, Sapporo, Japan
b Hokkaido University School of Medicine, Central CI Clinic, Sapporo, Japan

Address reprint requests to Kohsuke Kudo, Hokkaida University Graduate School of Medicine, Department of Radiology, N 15, W 7, Kita-ku, Sapporo, Japan, 060-8638

BACKGROUND AND PURPOSE: Blood flow of the internal jugular vein and intracranial venous sinuses is affected by respiratory state. The purpose of this study was to clarify the changes in flow velocity and direction and signal intensities of sigmoid sinuses on phase-contrast (PC) MR images obtained with regular breathing and with deep inspiratory breath holding.

METHODS: One hundred seven subjects without venous sinus abnormality were studied. Coronal 2D PC MR venography and axial 2D PC images with peripheral pulse gating were acquired with a 1.5-T MR unit, during regular breathing and deep inspiratory breath holding. The signal intensity changes of bilateral sigmoid sinuses on MR venograms and the changes of flow velocity and direction on the axial 2D PC images were analyzed.

RESULTS: Breath holding decreased signal intensities of the right and left sigmoid sinuses on MR venograms in 57 (53.3%) and 36 (33.6%) subjects, respectively. Increased signal intensity was observed in 12 (11.2%) and 33 (30.8%) subjects, respectively. In the flow analysis, retrograde flow was detected at the left sigmoid sinus in four subjects (3.7%) during regular breathing, which was normalized by breath holding. Flow velocities of the right and left sigmoid sinuses decreased during breath holding in 92 (86.0%) and 70 (65.4%) subjects, and increased in 15 (14.0%) and 37 (34.6%) subjects, respectively.

CONCLUSION: The signal intensities of sigmoid sinuses were affected by breath holding in about 2/3 of the subjects. Breath-holding maneuver can be used to increase blood flow and signal intensities of dural venous sinuses on PC MR venograms.




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
S. Meckel and S. G. Wetzel
Reply
Am. J. Roentgenol., August 1, 2008; 191(2): W77 - W77.