American Journal of Neuroradiology 26:2569-2572, November-December 2005
© 2005 American Society of Neuroradiology
Technical Note
INTERVENTIONAL
Volume Measurement of Intracranial Aneurysms from 3D Rotational Angiography: Improvement of Accuracy by Gradient Edge Detection
a Department of Electrical Engineering, Mathematics and Computer Sciences, Technical University Twente, Enschede, the Netherlands
b Department of Radiology, St. Elisabeth Ziekenhuis, Tilburg, the Netherlands
Address correspondence to Willem Jan van Rooij, MD, PhD, Department of Radiology, St. Elisabeth Ziekenhuis, Hilvarenbeekseweg 60, 5022 GC Tilburg, the Netherlands
Summary: Manual volume measurement of intracranial aneurysms from 3D rotational angiography varies on different threshold settings and, therefore, is operator-dependent. We developed and validated a method based on automatic gradient edge detection that is independent on threshold settings and provides an accurate and reproducible volume measurement. This method was compared with manual volume calculation in 13 aneurysm phantoms, and the results were significantly more accurate.
This article has been cited by other articles:
![]() |
M. Sluzewski and W.J. van Rooij Packing Performance of Helical Guglielmi Detachable Coil (GDC) 18 in Intracranial Aneurysms: A Comparison with Helical GDC 10 Coils and Complex Trufill/Orbit Coils AJNR Am. J. Neuroradiol., August 1, 2007; 28(7): 1384 - 1387. [Abstract] [Full Text] [PDF] |
||||
![]() |
A.K. Wakhloo, M.J. Gounis, J.S. Sandhu, N. Akkawi, A.E. Schenck, and I. Linfante Complex-Shaped Platinum Coils for Brain Aneurysms: Higher Packing Density, Improved Biomechanical Stability, and Midterm Angiographic Outcome AJNR Am. J. Neuroradiol., August 1, 2007; 28(7): 1395 - 1400. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Piotin, L. Spelle, C. Mounayer, M. T. Salles-Rezende, D. Giansante-Abud, R. Vanzin-Santos, and J. Moret Intracranial Aneurysms: Treatment with Bare Platinum Coils--Aneurysm Packing, Complex Coils, and Angiographic Recurrence Radiology, May 1, 2007; 243(2): 500 - 508. [Abstract] [Full Text] [PDF] |
||||
![]() |
W.J. van Rooij and M. Sluzewski Packing Performance of GDC 360{degrees} Coils in Intracranial Aneurysms: A Comparison with Complex Orbit Coils and Helical GDC 10 Coils AJNR Am. J. Neuroradiol., February 1, 2007; 28(2): 368 - 370. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. J. van Rooij and M. Sluzewski Durability of Treatment of Intracranial Aneurysms With Hydrocoils Is Not Different From Standard Platinum Coils Stroke, December 1, 2006; 37(12): 2874 - 2874. [Full Text] [PDF] |
||||
![]() |
W. J. van Rooij, M. Sluzewski, J. K. Goddard, C. J. Moran, D. T. Cross III, and C. P. Derdeyn Packing density in coiling of small intracranial aneurysms. AJNR Am. J. Neuroradiol., April 1, 2006; 27(4): 725 - 726. [Full Text] [PDF] |
||||