AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsai, L.-K.
Right arrow Articles by Yip, P.-K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsai, L.-K.
Right arrow Articles by Yip, P.-K.

BRAIN

Carotid Duplex Sonography in the Follow-Up of Intracranial Dural Arteriovenous Fistulae

Li-Kai Tsaia, Hon-Man Liub, Chien-Jung Lua, Jiann-Shing Jenga and Ping-Keung Yipa

a Department of Neurology National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei
b Department of Radiology, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei

Address reprint requests to Jiann-Shing Jeng, MD, Department of Neurology, National Taiwan University Hospital, No 7 Chung-Shan South Rd, Taipei 100, Taiwan

BACKGROUND AND PURPOSE: Studies to determine the value of noninvasive neurovascular studies for the effectiveness of treatment and long-term follow-up of dural arteriovenous fistulas (AVFs) are of clinical importance. We determined whether the serial changes of carotid duplex sonography (CDS) were correlated with the evolution of dural AVF status after treatment or follow-up.

METHODS: Four parameters of CDS were studied in two groups of patients with dural AVF: resistance index, end diastolic velocity, peak systolic velocity, and flow volume of the external carotid artery (ECA). The first group included 13 patients who received endovascular therapy, the efficacy of which was determined by the results of postembolization angiography. In the second group, 16 patients received only clinical and CDS follow-up. Evolution of clinical symptoms was recorded and classified as deteriorating, stationary, or improving. Patients underwent CDS before and after treatment (group 1) or at long-term follow-up (group 2).

RESULTS: In the first group, the resistance index of the ECA increased in patients with occluded or nearly occluded dural AVF after embolization (n = 7, P = .01), but it did not change significantly in patients with partial treatment (n = 6, P = .11). Of patients with occluded or nearly occluded dural AVF after embolization, the ECA resistance index increased in patients with noncavernous sinus dural AVF (n = 5, P = .003) but not in patients with cavernous sinus dural AVF (n = 2, P = .48). In the second group, CDS parameters—particularly the resistance index—were well correlated with clinical status during follow-up.

CONCLUSION: The resistance index of the ECA is correlated with the effectiveness of treatment and clinical evolution of dural AVF.