AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by van der Schaaf, I.
Right arrow Articles by van Osch, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by van der Schaaf, I.
Right arrow Articles by van Osch, T.

BRAIN

Influence of Partial Volume on Venous Output and Arterial Input Function

I. van der Schaafa, E.-J. Vonkena, A. Waaijera, B. Velthuisa, M. Quistb and T. van Oscha,c

a Department of Radiology, University Medical Center Utrechtv, Best, the Netherlands
b Philips Medical Systems, Best, the Netherlands
c Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands

Address correspondence to Irene C. van der Schaaf, Department of Radiology E01.132, University Medical Center Utrecht, P.O. Box 85500, 3508 GA Utrecht, the Netherlands

Abstract

BACKGROUND: CT perfusion (CTP) is an important diagnostic tool for the imaging of cerebral hemodynamics. To obtain quantitative values of cerebral blood volume (CBV), blood flow (CBF), and mean transit time (MTT), measurement of the arterial input function (AIF) is required. To correct for partial volume effects (PVEs), it is common to normalize the AIF with respect to the venous output function (VOF). This correction assumes that measurement of the VOF is unhampered by PVEs. The purpose of this study was to evaluate the effect of PVE on the measurement of the AIF and VOF and, consequently, on the absolute perfusion parameters.

METHODS: In 10 patients the mean area under the curve (AUC) of the AIF and VOF were quantified for 3-, 6-, and 12-mm-thick sections. Differences in the mean (1) AUC of the VOF, (2) AUC of the AIF, and (3) width of the AIF were compared for the 3 section thicknesses, and the influence on the absolute values of CBV, CBF, and MTT were studied.

RESULTS: With thinner sections, the AUC of the VOF and the AIF increased significantly and the width of the AIF decreased slightly. Differences in AUC between the 3 section thicknesses were larger for the AIF than for the VOF.

CONCLUSION: PVEs affect not only the AIF, but also the VOF. This results in an overestimation of CBV and CBF when a thicker section is used. To avoid PVE, VOF measurements should be performed at lower section thicknesses.




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
A. Waaijer, I.C. van der Schaaf, B.K. Velthuis, M. Quist, M.J.P. van Osch, E.P.A. Vonken, M.S. van Leeuwen, and M. Prokop
Reproducibility of Quantitative CT Brain Perfusion Measurements in Patients with Symptomatic Unilateral Carotid Artery Stenosis
AJNR Am. J. Neuroradiol., May 1, 2007; 28(5): 927 - 932.
[Abstract] [Full Text] [PDF]