AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bartlett, E.S.
Right arrow Articles by Fox, A.J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bartlett, E.S.
Right arrow Articles by Fox, A.J.

BRAIN

Correlation of Carotid Stenosis Diameter and Cross-Sectional Areas with CT Angiography

E.S. Bartletta, S.P. Symonsb and A.J. Foxb

a Department of Neuroradiology, Northwestern University, Chicago, Ill
b Department of Neuroradiology, Sunnybrook and Women’s College Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada

Address correspondence to Allan J. Fox, MD, Department of Neuroradiology, Sunnybrook and Women’s College Heath Sciences Centre, University of Toronto, 2075 Bayview Ave, Room AG31b, Toronto, ON M4N 3M5, Canada

PURPOSE: Carotid stenosis quantification traditionally uses measurements of narrowest stenosis diameter. The stenotic carotid lumen, however, is often irregularly shaped. New PACS workstation tools allow for more precise calculation of carotid geometry. We compare the narrowest stenosis diameter with 2D area stenosis measurements, with the hypothesis that the narrowest diameter is a good predictor of the more precise area measurement.

METHODS: Two neuroradiologists evaluated 178 stenosed carotids in a blinded protocol. Carotid artery bulb stenosis was identified on axial CT angiography and measured in millimeters at its narrowest diameter. An AGFA Impax 4.5 Volume Tool (VT) using Hounsfield units was used to estimate the cross-sectional area of the contrast luminogram. Pearson correlation coefficients were calculated between the millimeter stenosis and the VT area, as well as between the VT area and the calculated area (radius based on narrowest diameter). Regression analysis was performed with the VT area and narrowest diameter datasets.

RESULTS: Excellent interobserver correlation (correlation coefficients, 0.71–0.85; 2-tailed significance =.01) permitted averaging of measurement data. There is excellent correlation between the VT area and the narrowest diameter (correlation coefficient,0.88; n = 176). The VT area was generally greater than the calculated area by an average of 2.77 mm2. There was excellent correlation between the VT area and the calculated area (correlation coefficient, 0.87; n = 176). Regression analysis shows the ability of the diameter measurements to predict corresponding area stenosis.

CONCLUSION: Although some carotid stenoses are irregularly shaped and noncircular, measurement of the narrowest stenosis is a reasonably reliable predictor of the cross-sectional area.




This article has been cited by other articles:


Home page
StrokeHome page
A. J. Fox, S. P. Symons, R. I. Aviv, P. Howard, R. Yeung, and E. S. Bartlett
Should Modeling Methodology Suppress Anatomic Excellence?
Stroke, November 1, 2009; 40(11): 3411 - 3412.
[Full Text] [PDF]


Home page
StrokeHome page
H. C. Schumacher, P. M. Meyers, R. T. Higashida, C. P. Derdeyn, S. D. Lavine, G. M. Nesbit, D. Sacks, P. Rasmussen, and L. R. Wechsler
Reporting Standards for Angioplasty and Stent-Assisted Angioplasty for Intracranial Atherosclerosis
Stroke, May 1, 2009; 40(5): e348 - e365.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
E.S. Bartlett, T.D. Walters, S.P. Symons, R.I. Aviv, and A.J. Fox
Classification of Carotid Stenosis by Millimeter CT Angiography Measures: Effects of Prevalence and Gender
AJNR Am. J. Neuroradiol., October 1, 2008; 29(9): 1677 - 1683.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
E. S. Bartlett, T. D. Walters, S. P. Symons, and A. J. Fox
Response to Letter by Bladin et al
Stroke, October 1, 2007; 38(10): e102 - e102.
[Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
G. Schulte-Altedorneburg, F. J. Ahlhelm, E. S. Bartlett, S. P. Symons, and A. J. Fox
Simplification of the residual lumen geometry in measuring carodid stenosis.
AJNR Am. J. Neuroradiol., May 1, 2007; 28(5): 804 - 804.
[Full Text] [PDF]


Home page
StrokeHome page
K. R. Nandalur, A. D. Hardie, P. Raghavan, M. J. Schipper, E. Baskurt, and C. M. Kramer
Composition of the Stable Carotid Plaque: Insights From a Multidetector Computed Tomography Study of Plaque Volume
Stroke, March 1, 2007; 38(3): 935 - 940.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
E. S. Bartlett, T. D. Walters, S. P. Symons, and A. J. Fox
Carotid Stenosis Index Revisited With Direct CT Angiography Measurement of Carotid Arteries to Quantify Carotid Stenosis
Stroke, February 1, 2007; 38(2): 286 - 291.
[Abstract] [Full Text] [PDF]