AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cohnen, M.
Right arrow Articles by Mödder, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cohnen, M.
Right arrow Articles by Mödder, U.

BRAIN

Radiation Exposure of Patients in Comprehensive Computed Tomography of the Head in Acute Stroke

M. Cohnena, H.-J. Wittsacka, S. Assadia, K. Muskallab, A. Ringelsteina, L.W. Polla, A. Saleha and U. Möddera

a Institute of Diagnostic Radiology, University Hospital Düsseldorf, Düsseldorf, Germany
b Department of Radiation Oncology, University Hospital Düsseldorf, Düsseldorf, Germany

Address correspondence to Priv.-Doz. Dr. M. Cohnen, Institute of Diagnostic Radiology, University Hospital, MNR-Klinik, Heinrich-Heine-University, Moorenstr. 5, 40225 Düsseldorf, Germany; e-mail: cohnen{at}med.uni-duesseldorf.de

BACKGROUND AND PURPOSE: To assess patient radiation exposure in comprehensive stroke imaging using multidetector row CT (MDCT) combining standard CT of the head, cerebral perfusion (CTP), and CT angiography (CTA) studies.

METHODS: Examination protocols for CT and CTA of cerebral and cervical vessels, as well as CTP were simulated using a Somatom Sensation Cardiac 64. Effective doses were derived from measurements with the use of lithium-fluoride thermoluminescent dosimeters (LiF-TLD) at several organ sites using an Alderson-Rando phantom.

RESULTS: LiF-TLD measurements resulted in effective doses of 1.7 mSv for CT, 1.9 mSv for CTA of intracranial vessels, and 2.8 mSv for CTA of cervical vessels, respectively. Depending on examination parameters, effective doses varied between 1.1 and 5.0 mSv for cerebral CTP. For CTP, local doses in the area of the primary beam ranged between 114 and 444 mGy.

CONCLUSIONS: Comprehensive stroke imaging may result in up to 9.5 mSv with possible local doses of 490 mGy. Although critical doses for organ damage (eg, cataract formation or hair loss) are not reached, physicians need to be aware of possible radiation induced sequelae particularly in repetitive examinations.




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
E.J. Lee, S.K. Lee, R. Agid, P. Howard, J.M. Bae, and K. terBrugge
Comparison of Image Quality and Radiation Dose between Fixed Tube Current and Combined Automatic Tube Current Modulation in Craniocervical CT Angiography
AJNR Am. J. Neuroradiol., October 1, 2009; 30(9): 1754 - 1759.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
N. Yahyavi-Firouz-Abadi, B.L. Wynn, F.J. Rybicki, M.L. Steigner, A.Z. Hussain, R. Mather, E.H. Hanson, M. Ansarinia, and W.W. Orrison Jr.
Steroid-Responsive Large Vessel Vasculitis: Application of Whole-Brain 320-Detector Row Dynamic Volume CT Angiography and Perfusion
AJNR Am. J. Neuroradiol., August 1, 2009; 30(7): 1409 - 1411.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E SIEBERT, G BOHNER, M DEWEY, F MASUHR, K T HOFFMANN, J MEWS, F ENGELKEN, H C BAUKNECHT, S DIEKMANN, and R KLINGEBIEL
320-slice CT neuroimaging: initial clinical experience and image quality evaluation
Br. J. Radiol., July 1, 2009; 82(979): 561 - 570.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
T.J. Huynh, B. Murphy, J.A. Pettersen, H. Tu, D.J. Sahlas, L. Zhang, S.P. Symons, S. Black, T.-Y. Lee, and R.I. Aviv
CT Perfusion Quantification of Small-Vessel Ischemic Severity
AJNR Am. J. Neuroradiol., November 1, 2008; 29(10): 1831 - 1836.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. W. Youn, J. H. Kim, Y.-C. Weon, S. H. Kim, M.-K. Han, and H.-J. Bae
Perfusion CT of the Brain Using 40-mm-Wide Detector and Toggling Table Technique for Initial Imaging of Acute Stroke
Am. J. Roentgenol., September 1, 2008; 191(3): W120 - W126.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Radiology, July 1, 2008; 248(1): 254 - 263.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
J. A. Pettersen, R. I. Aviv, S. E. Black, A. J. Fox, A. Lim, and B. J. Murray
Global Hemispheric CT Hypoperfusion May Differentiate Headache With Associated Neurological Deficits and Lymphocytosis From Acute Stroke
Stroke, February 1, 2008; 39(2): 492 - 493.
[Full Text] [PDF]


Home page
StrokeHome page
A. G. Sorensen and W.-D. Heiss
Advances in Imaging 2007
Stroke, February 1, 2008; 39(2): 276 - 278.
[Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
R.I. Aviv, J. Mandelcorn, S. Chakraborty, D. Gladstone, S. Malham, G. Tomlinson, A.J. Fox, and S. Symons
Alberta Stroke Program Early CT Scoring of CT Perfusion in Early Stroke Visualization and Assessment
AJNR Am. J. Neuroradiol., November 1, 2007; 28(10): 1975 - 1980.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
C. H. Marshall
From flatland to the fourth dimension.
AJNR Am. J. Neuroradiol., September 1, 2006; 27(8): 1746 - 1746.
[Full Text] [PDF]