AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Matsumoto, M.
Right arrow Articles by Shishido, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Matsumoto, M.
Right arrow Articles by Shishido, F.

BRAIN

Dynamic 3D-CT Angiography

M. Matsumotoa, N. Kodamaa, Y. Endoa, J. Sakumaa, Ky. Suzukia, T. Sasakia, K. Murakamib, Ke. Suzukib, T. Katakurab and F. Shishidob

a Department of Neurosurgery, Fukushima Medical University, Fukushima, Japan
b Radiology, Fukushima Medical University, Fukushima, Japan

Address correspondence to Masato Matsumoto, MD, Department of Neurosurgery, Fukushima Medical University, 1 Hikarigaoka, Fukushima 960-1295, Japan; e-mail: mat{at}fmu.ac.jp

BACKGROUND AND PURPOSE: 3D-CT angiography (3D-CTA), a vessel-cast technique, is useful in the diagnosis of patients with brain lesions and cerebrovascular disease. However, it provides no information on blood-flow dynamics. Therefore, we developed a new technique, dynamic 3D-CTA (d3D-CTA), that yields 3D images of the vasculature and allows assessment of the hemodynamics and of the cerebral perfusion.

METHODS: We subjected 12 patients to d3D-CTA; 7 had brain tumors, 4 had arteriovenous malformations (AVMs), and 1 presented with cervical internal carotid artery occlusion. d3D-CTA was performed with a multidetector-row CT scanner with 64 detectors; the parameters were 0.5-mm section thickness, 0.5 seconds per rotation, 135 kV, and 150 mA. Contrast medium (total volume, 30–35 mL) was injected at 6–7 mL/s; scanning was started after a 5-second delay. Scans were generated with volume-rendering reconstruction and displayed in cine mode.

RESULTS: We succeeded in obtaining d3D-CTA scans in all cases. The scans yielded 3D information on the vascular structures and hemodynamics and on the status of the cerebral perfusion.

CONCLUSION: d3D-CTA facilitates the acquisition of information on the vascular and cerebral dynamic blood flow on 3D-CTA images. Despite the relatively high radiation exposure and contrast injection speed and its limited scan range, this technique is useful for the diagnosis of patients with brain tumors or cerebrovascular disease and for treatment planning.




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
V. Goh, J. Liaw, C. I. Bartram, and S. Halligan
Effect of Temporal Interval Between Scan Acquisitions on Quantitative Vascular Parameters in Colorectal Cancer: Implications for Helical Volumetric Perfusion CT Techniques
Am. J. Roentgenol., December 1, 2008; 191(6): W288 - W292.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. J. Kaufmann and D. F. Kallmes
Diagnostic Cerebral Angiography: Archaic and Complication-Prone or Here to Stay for Another 80 Years?
Am. J. Roentgenol., June 1, 2008; 190(6): 1435 - 1437.
[Full Text] [PDF]


Home page
Arch OphthalmolHome page
A. Kahana, M. J. Lucarelli, A. M. Grayev, J. J. Van Buren, C. N. Burkat, and L. R. Gentry
Noninvasive Dynamic Magnetic Resonance Angiography With Time-Resolved Imaging of Contrast KineticS (TRICKS) in the Evaluation of Orbital Vascular Lesions
Arch Ophthalmol, December 1, 2007; 125(12): 1635 - 1642.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
R. L. DeLaPaz and for the Expert Panel on Neurologic Imaging
Cerebrovascular Disease
AJNR Am. J. Neuroradiol., June 1, 2007; 28(6): 1197 - 1199.
[Full Text] [PDF]