AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by D’Ercole, L.
Right arrow Articles by Andreucci, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by D’Ercole, L.
Right arrow Articles by Andreucci, L.

INTERVENTIONAL

A Study on Maximum Skin Dose in Cerebral Embolization Procedures

L. D’Ercolea, L. Mantovania, F. Zappoli Thyrionb, M. Bocchiolaa, A. Azzarettib, F. Di Mariab, C. Massa Saluzzob, P. Quarettib, G. Rodolicob, P. Scagnellib and L. Andreuccia

a Department of Medical Physics, Istituto di Ricovero e Cura a Carattere Scientifico, San Matteo Hospital, Pavia, Italy
b Department of Radiology, Istituto di Ricovero e Cura a Carattere Scientifico, San Matteo Hospital, Pavia, Italy

Address correspondence to Loredana D’Ercole, Department of Medical Physics, IRCCS, San Matteo Hospital, Viale Golgi 19, 27100 Pavia, Italy; e-mail: l.dercole{at}smatteo.pv.it

BACKGROUND AND PURPOSE: It is essential to measure the skin dose of radiation received by patients during interventional neuroradiologic procedures performed under fluoroscopic guidance, such as embolization of cerebral aneurysms, which is regarded as a high-dose interventional radiology procedure. In this study, we report a method for evaluating maximum skin dose (MSD), an ideal marker of radiation-induced effects, based on an innovative use of radiochromic films.

MATERIALS AND METHODS: Forty-eight procedures were studied in 42 patients undergoing embolization of cerebral aneurysms. Fluoroscopic and digital dose-area product (DAP), fluoroscopy time, and total number of acquired images were recorded for all procedures. The MSD was measured using Gafchromic XR type R films.

RESULTS: The MSD was measured in one group of 21 procedures. The coefficient ({kappa}) of the interpolation line between the skin dose and the DAP ({kappa} = 0.0029 cm–2) was determined. An approximate value of MSD from the DAP for the remaining 27 procedures was estimated by means of an interpolation line. The mean MSD was found to be 1.16 Gy (range, 0.23–3.20 Gy).

CONCLUSION: The use of radiochromic XR type R films was shown to be an effective method for measuring MSD. These films have the advantage of supplying information on both the maximum dose and the distribution of the dose: this satisfies the most stringent interpretation of Food and Drug Administration, American College of Radiology, and international recommendations for recording skin dose.




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
T. Moritake, Y. Matsumaru, T. Takigawa, K. Nishizawa, A. Matsumura, and K. Tsuboi
Dose Measurement on Both Patients and Operators during Neurointerventional Procedures Using Photoluminescence Glass Dosimeters
AJNR Am. J. Neuroradiol., November 1, 2008; 29(10): 1910 - 1917.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. Geisel, J. T. Heverhagen, M. Kalinowski, and H.-J. Wagner
DNA Double-Strand Breaks after Percutaneous Transluminal Angioplasty
Radiology, September 1, 2008; 248(3): 852 - 859.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
S. Suzuki, S. Furui, Y. Matsumaru, S. Nobuyuki, M. Ebara, T. Abe, and D. Itoh
Patient Skin Dose during Neuroembolization by Multiple-Point Measurement Using a Radiosensitive Indicator
AJNR Am. J. Neuroradiol., June 1, 2008; 29(6): 1076 - 1081.
[Abstract] [Full Text] [PDF]