AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Deutschmann, H.A.
Right arrow Articles by Klein, G.E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Deutschmann, H.A.
Right arrow Articles by Klein, G.E.

INTERVENTIONAL

Diagnostic Accuracy of 3D Time-of-Flight MR Angiography Compared with Digital Subtraction Angiography for Follow-Up of Coiled Intracranial Aneurysms: Influence of Aneurysm Size

H.A. Deutschmanna, M. Augustina, J. Simbrunnera, B. Ungera, H. Schoellnasta, G.A. Fritza and G.E. Kleina

a From the Medical University of Graz, Department of Radiology, University of Hospital Graz, Auenbruggerplatz 9, A-8036 Graz, Austria

Correspondence: Hannes A. Deutschmann, Medical University Graz, Department of Radiology, Univ. Hospital Graz, Auenbruggerplatz 9, A-8036 Graz, Austria; e-mail: hannes.deutschmann{at}meduni-graz.at

BACKGROUND AND PURPOSE: 3D time-of-flight MR angiography (3D TOF MRA) may be used as noninvasive alternative to digital subtraction angiography (DSA) for the follow-up of patients with intracranial aneurysms treated with Guglielmi detachable coils (GDCs). We aimed to determine the influence of aneurysm size and location on diagnostic accuracy of 3D TOF MRA for follow-up of intracranial aneurysms treated with GDCs.

MATERIALS AND METHODS: Two hundred and one 3D TOF MRAs in 127 consecutive patients with 136 aneurysms were compared with DSA as standard of reference. Sensitivity and specificity of 3D TOF MRA for detection of residual or reperfusion of the aneurysms was calculated with regard to aneurysm size and location.

RESULTS: Overall sensitivity and specificity of MRA was 88.5% and 92.9%, respectively. Sensitivity was lower for aneurysms ≤5 mm (72.2%) and ≤3 mm (63.6%). In addition to the small aneurysm size, interpretation of MR angiograms was compromised by susceptibility artifacts at the air-bone interface, arterial overlap, and pulsation-induced artifacts. The small number of disagreements between MRA and DSA hampered reliable interpretation of the possible influence of aneurysm location on MRA accuracy.

CONCLUSION: The sensitivity of 3D TOF MRA for detection of reperfusion or residual perfusion of coiled intracranial aneurysms varies considerably depending on the size of the aneurysms. No conclusions can be drawn regarding a possible influence of aneurysm location on diagnostic accuracy of 3D TOF MRA. These findings may influence the decision about whether to replace DSA by 3D TOF MRA for the follow-up of patients with intracranial aneurysms treated with GDCs.




This article has been cited by other articles: