AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gauvrit, J.-Y.
Right arrow Articles by Chen, Q.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gauvrit, J.-Y.
Right arrow Articles by Chen, Q.

INTERVENTIONAL

Time-Resolved MR Angiography: Optimal Parallel Imaging Method

J.-Y. Gauvrita,b, M. Lawb, J. Xuc, R. Carsonb, P. Sunenshineb and Q. Chenb

a Department of Neuroradiology, EA 2691, Salengro Hospital, University Hospital of Lille, Lille, France
b Department of Radiology, MRI Department, New York University Medical Center, New York, NY
c Siemens Medical Solutions USA Inc., New York, NY

Address correspondence to J.-Y. Gauvrit, MD, Service de Neuroradiologie, Hôpital Roger Salengro, Rue Emile Laine, 59037 Lille Cedex France; e-mail: jygauvrit{at}chru-lille.fr

BACKGROUND AND PURPOSE: Time-resolved (TR) MR angiography (MRA) using parallel imaging techniques is proving to have clinical utility for improving MRA spatial and temporal resolution and separating arterial from venous anatomy. The purpose of this study was to evaluate TR MRA of the intracranial vessels at different integrated parallel acquisition technique (IPAT) factors.

MATERIALS AND METHODS: 3D TR MRA using time-resolved echo-shared angiographic technique was performed with different IPAT factors (0, 2, 3) at 1.5T, resulting in temporal resolutions of 4.0, 1.7, and 1.3 seconds, respectively. We studied 14 subjects, comprising 12 patients with various pathologic conditions and 2 healthy subjects. The brain volume was covered by 36 partitions, and a bolus of 5 mL of gadopentate dimeglumine was administered. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), the number of frames that distinguished between arterial and venous phases, the conspicuity of the vasculature, and artifacts were analyzed.

RESULTS: There was no significant difference in SNR between IPAT factors 0 and 2. Moreover, SNR was significantly lower with IPAT 3 than with IPAT 0 or 2. Smaller vessel segments (M3 and P3) were rated significantly inferior with TR MRA IPAT 2 or 3 compared with MRA without IPAT. For larger proximal vessels (A1 and A2 segments of anterior cerebral artery, M1 and M2 segments of middle cerebral artery, P2 segment of posterior cerebral artery, and basilar artery), there was no difference between TR MRA IPAT 0 and 2.

CONCLUSION: To obtain arterial and venous information in a clinical setting, intracranial TR MRA is best performed with an IPAT factor of 2 with at least 5 mL of contrast.




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
R.P. Lim, M. Shapiro, E.Y. Wang, M. Law, J.S. Babb, L.E. Rueff, J.S. Jacob, S. Kim, R.H. Carson, T.P. Mulholland, et al.
3D Time-Resolved MR Angiography (MRA) of the Carotid Arteries with Time-Resolved Imaging with Stochastic Trajectories: Comparison with 3D Contrast-Enhanced Bolus-Chase MRA and 3D Time-Of-Flight MRA
AJNR Am. J. Neuroradiol., November 1, 2008; 29(10): 1847 - 1854.
[Abstract] [Full Text] [PDF]