AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mulkens, T.H.
Right arrow Articles by Termote, J.-L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mulkens, T.H.
Right arrow Articles by Termote, J.-L.

SPINE

Comparison of Low-Dose With Standard-Dose Multidetector CT in Cervical Spine Trauma

T.H. Mulkensa, P. Marchala, S. Daineffea, R. Salgadoa, P. Bellincka, B. te Rijdtb, B. Kegelaersb and J.-L. Termotea

a Departments of Radiology, Heilig Hart Ziekenhuis, Lier, Belgium
b Neurosurgery, Heilig Hart Ziekenhuis, Lier, Belgium

Please address correspondence to Tom H. Mulkens, Department of Radiology, Heilig Hart Ziekenhuis, Mechelsestraat 24, B 2500 Lier, Belgium; e-mail: tom.mulkens{at}hhzhlier.be

BACKGROUND AND PURPOSE: The purpose of this work was to evaluate the possible use of low-dose multidetector CT (MDCT) in cervical clearance of patients with blunt trauma.

MATERIALS AND METHODS: A total of 191 patients underwent cervical spine MDCT with 6- and 16-MDCT: standard-dose (n = 51) and low-dose MDCT with tube current modulation at high (n = 70) and low (n = 70) tube voltage (kilovolts). Effective dose, image noise, and subjective image quality were calculated in all of the patients.

RESULTS: MDCT found 18 patients (9.4%) with a cervical spine fracture, 3 in the standard-dose and 15 in the low-dose group, 14 of them with unstable lesions. Tube current modulation reduced the dose by 50%–61% in all of the low-dose examinations. The mean effective dose was 3.75, 1.57, and 1.08 mSv, and mean image noise was 14.82, 17.46, and 19.72 Hounsfield units for standard dose and low dose with high and low kilovolt examinations, respectively. These differences in mean effective dose and image noise were significant between the 3 examination groups (Kruskal-Wallis test: P < .0001 and P = .0001). Evaluation of subjective image quality by 2 radiologists and 2 residents showed no significant difference in image quality score among the 3 examination groups (Kruskal-Wallis tests, P = .61, .32, .18, and .31). All of the reviewers correctly detected 18 fractures, except 1 resident, who missed 3 fractures.

CONCLUSION: Low-dose cervical spine MDCT in patients with blunt trauma gives a substantial dose reduction of 61%–71%, compared with standard-dose MDCT, with a small increase in image noise and without difference in subjective image quality evaluation.




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
C. T. Silva, A. S. Doria, J. Traubici, R. Moineddin, J. Davila, and M. Shroff
Do Additional Views Improve the Diagnostic Performance of Cervical Spine Radiography in Pediatric Trauma?
Am. J. Roentgenol., February 1, 2010; 194(2): 500 - 508.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
E.J. Lee, S.K. Lee, R. Agid, P. Howard, J.M. Bae, and K. terBrugge
Comparison of Image Quality and Radiation Dose between Fixed Tube Current and Combined Automatic Tube Current Modulation in Craniocervical CT Angiography
AJNR Am. J. Neuroradiol., October 1, 2009; 30(9): 1754 - 1759.
[Abstract] [Full Text] [PDF]