AJDRAJNR - American Journal of Neuroradiology

Published ahead of print on January 9, 2008
doi: 10.3174/ajnr.A0936

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
ajnr.A0936v1
29/2/217    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by White, P.M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by White, P.M.

EXPEDITED PUBLICATION

HydroCoil Endovascular Aneurysm Occlusion and Packing Study (HELPS Trial): Procedural Safety and Operator-Assessed Efficacy Results

P.M. Whitea,b, S.C. Lewisb, H. Nahserc, R.J. Sellara, T. Goddardd, A. Gholkare on behalf of the HELPS Trial Collaboration

a From the Department of Neuroradiology, Western General Hospital, Edinburgh, UK
b University of Edinburgh Neurosciences Trials Unit, Edinburgh, UK
c Walton Centre for Neurosurgery and Neurology, Liverpool, UK
d Leeds General Infirmary, Leeds, UK
e Department of Neuroradiology, Newcastle General Hospital, Newcastle, UK

Please address correspondence to P.M. White, MD, Consultant Neuroradiologist, Department of Neuroradiology, Western General Hospital, Edinburgh, EH4 2XU, UK; e-mail: pmw{at}skull.dcn.ed.ac.uk

BACKGROUND AND PURPOSE: Coated coils have been in clinical use for several years without robust evidence to determine their safety/efficacy. The HydroCoil Endovascular Aneurysm Occlusion and Packing Study (HELPS) addresses this deficiency for the HydroCoil embolic system. This article reports periprocedural safety/operator-assessed angiographic results from HELPS.

MATERIALS AND METHODS: Patients were randomized to the hydrogel coil or control arms by using concealed allocation with minimization matching groups. Any bare platinum coils were allowed in the control arm, and assist devices could be used as clinically required. Both recently ruptured and not recently ruptured/unruptured aneurysms were included. Analysis was on an intention-to-treat basis.

RESULTS: Four hundred ninety-nine patients were recruited. Coiling was successful in 98.6%. Mean aneurysm size was 6.5 mm (26% were ≥10 mm), 53% were recently ruptured aneurysms, and an assist device was used in 46%. Seventy procedural adverse events were reported in hydrogel coils and 86 in control arms. The 3-month mortality rate was 3.6% in hydrogel coils and 2.0% in control arms; the difference was not significant (P = .6). There was a lower 2-month mortality rate in the HELPS subarachnoid hemorrhage cohort (4.1%) than would be anticipated from the International Subarachnoid Aneurysm Trial (7%). There was a trend toward increased adverse events when assist devices were used, which was substantial for stents deployed in recently ruptured aneurysms. Ninety-six percent of patients discharged were World Federation of Neurosurgeons grade 0–2 at discharge. No difference was found between arms in the operator assessment of angiographic occlusions (P = .3).

CONCLUSION: These HELPS results reinforce coiling as an effective treatment for aneurysms, with an excellent technical success rate. Hydrogel coils can be used in a wide spectrum of aneurysms with a risk profile equivalent to that of bare platinum.




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
I. Craven, U.J. Patel, A. Gibson, and S.C. Coley
Symptomatic Perianeurysmal Edema Following Bare Platinum Embolization of a Small Unruptured Cerebral Aneurysm
AJNR Am. J. Neuroradiol., November 1, 2009; 30(10): 1998 - 2000.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
T. Gunnarsson, F.C. Tong, P. Klurfan, C.M. Cawley, and J.E. Dion
Angiographic and Clinical Outcomes in 200 Consecutive Patients with Cerebral Aneurysm Treated with Hydrogel-Coated Coils
AJNR Am. J. Neuroradiol., October 1, 2009; 30(9): 1657 - 1664.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
W. Brinjikji, H.J Cloft, and D.F. Kallmes
Difficult Aneurysms for Endovascular Treatment: Overwide or Undertall?
AJNR Am. J. Neuroradiol., September 1, 2009; 30(8): 1513 - 1517.
[Abstract] [Full Text] [PDF]


Home page
Journal of NeuroInterventional SurgeryHome page
D Fiorella, P Lylyk, I Szikora, M E Kelly, F C Albuquerque, C G McDougall, and P K Nelson
Curative cerebrovascular reconstruction with the Pipeline embolization device: the emergence of definitive endovascular therapy for intracranial aneurysms
JNIS, July 1, 2009; 1(1): 56 - 65.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
P.M. White and J. Raymond
Endovascular Coiling of Cerebral Aneurysms Using "Bioactive" or Coated-Coil Technologies: A Systematic Review of the Literature
AJNR Am. J. Neuroradiol., February 1, 2009; 30(2): 219 - 226.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J.P.P. Peluso, W.J. van Rooij, M. Sluzewski, and G.N. Beute
A New Self-Expandable Nitinol Stent for the Treatment of Wide-Neck Aneurysms: Initial Clinical Experience
AJNR Am. J. Neuroradiol., August 1, 2008; 29(7): 1405 - 1408.
[Abstract] [Full Text] [PDF]