AJDRAJNR - American Journal of Neuroradiology

Published ahead of print on February 29, 2008
doi: 10.3174/ajnr.A1021

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
ajnr.A1021v1
29/5/991    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by van Rooij, W.J.
Right arrow Articles by Sluzewski, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by van Rooij, W.J.
Right arrow Articles by Sluzewski, M.

INTERVENTIONAL

Results of 101 Aneurysms Treated with Polyglycolic/Polylactic Acid Microfilament Nexus Coils Compared with Historical Controls Treated with Standard Coils

W.J. van Rooija, A.N. de Gasta and M. Sluzewskia

a From the Department of Radiology, St. Elisabeth Ziekenhuis, Tilburg, the Netherlands

Please address correspondence to Willem Jan van Rooij, MD, PhD, Department of Radiology, St. Elisabeth Ziekenhuis, Hilvarenbeekseweg 60, 5022 GC Tilburg, the Netherlands; e-mail: radiol{at}knmg.nl

BACKGROUND AND PURPOSE: Polyglycolic/polylactic acid (PGLA) addition to bare platinum coils is intended to reduce the reopening rate of coiled intracranial aneurysms. Nexus coils are standard complex platinum coils with interwoven PGLA microfilament threads. We present the clinical results of 101 intracranial aneurysms treated with Nexus coils.

MATERIALS AND METHODS: Results of coiling of 101 aneurysms treated with Nexus coils were compared with our results of coiling of 120 aneurysms with Guglielmi detachable coils (GDC 10) and 115 with Trufill coils treated between May 2003 and December 2004 with the same treatment protocol. Rate of complications, mean aneurysmal volume, packing attenuation, incomplete aneurysmal occlusion at 6 months, and rates of retreatment were compared.

RESULTS: Initial occlusion in aneurysms treated with Nexus coils was (near) complete in 97 aneurysms and incomplete in 4 aneurysms. There were no permanent procedural complications (0/95 patients, 0%; 97.5% CI, 0.0% to 3.3%). Mean aneurysmal volume was 180.2 mm3 (range, 5–1624 mm3). Mean packing was 19.4% (range, 7.5% to 38.9%). Six months’ angiographic follow-up in 87 of 101 aneurysms showed incomplete occlusion in 14 (16%), and 12 (14%) of those had additional coiling. Mean packing of 19.4% of Nexus coils was significantly lower than 22.9% for GDC 10 and 29.7% for Trufill coils. Other clinical results were not significantly different.

CONCLUSION: In this series, PGLA microfilament Nexus coils were safe to use with clinical results comparable with those of standard platinum coils. This study gives additional evidence of the lack of beneficial effect of PGLA addition to reduce the reopening rate of coiled intracranial aneurysms.




This article has been cited by other articles:


Home page
StrokeHome page
S. P. Ferns, M. E.S. Sprengers, W. J. van Rooij, G. J.E. Rinkel, J. C. van Rijn, S. Bipat, M. Sluzewski, and C. B.L.M. Majoie
Coiling of Intracranial Aneurysms: A Systematic Review on Initial Occlusion and Reopening and Retreatment Rates
Stroke, August 1, 2009; 40(8): e523 - e529.
[Abstract] [Full Text] [PDF]


Home page
StrokeHome page
A. K. Wakhloo, M. J. Deleo III, and M. M. Brown
Advances in Interventional Neuroradiology
Stroke, May 1, 2009; 40(5): e305 - e312.
[Abstract] [Full Text] [PDF]