AJDRAJNR - American Journal of Neuroradiology

Published ahead of print on April 24, 2008
doi: 10.3174/ajnr.A1104

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
ajnr.A1104v1
29/7/1405    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Peluso, J.P.P.
Right arrow Articles by Beute, G.N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Peluso, J.P.P.
Right arrow Articles by Beute, G.N.

INTERVENTIONAL

A New Self-Expandable Nitinol Stent for the Treatment of Wide-Neck Aneurysms: Initial Clinical Experience

J.P.P. Pelusoa, W.J. van Rooija, M. Sluzewskia and G.N. Beuteb

a Department of Radiology, St. Elisabeth Ziekenhuis, Tilburg, the Netherlands
b Department of Neurosurgery, St. Elisabeth Ziekenhuis, Tilburg, the Netherlands

Please address correspondence to Willem Jan van Rooij, MD, PhD, Department of Radiology, St. Elisabeth Ziekenhuis, Hilvarenbeekseweg 60, 5022 GC Tilburg, the Netherlands; e-mail: wjjvanrooij{at}gmail.com

BACKGROUND AND PURPOSE: Stent systems for intracranial use are continuously improved. We report our initial experience using a new self-expanding easy-to-place nitinol stent (Enterprise) in the treatment of wide-neck intracranial aneurysms.

MATERIALS AND METHODS: Between January and October 2007, 16 aneurysms in 15 patients were treated with stent assistance. Aneurysm size was a mean of 13.2 mm (median, 12 mm; range, 7–30 mm). Eight aneurysms had reopened after prior coiling, and 8 aneurysms were primarily treated, 1 after acute subarachnoid hemorrhage. Response to antiplatelet premedication was tested with a P2Y12 assay before stent placement. On a 3D angiographic workstation, stent placement was simulated to assess vessel caliber and appropriate stent length.

RESULTS: In all aneurysms, the stent could be placed at the exact location as predicted from the computer simulation. Stent placement proved to be technically easy without the need for recapture in all patients. Although placement of the microcatheter through the stent struts and subsequent coil placement was challenging in some patients, coiling after stent placement resulted in complete or near-complete occlusion in all aneurysms. There were no technical or clinical complications. At 6 months, angiographic follow-up in 14 aneurysms revealed 4 aneurysms recanalized to 80% occlusion, 3 of which were additionally coiled.

CONCLUSION: In this small series, delivery and deployment of the Enterprise stent was technically easy. There were no technical or clinical complications. The device was valuable in the treatment of wide-neck aneurysms. The need for antiplatelet medication in patients treated with this and other stents remains a significant disadvantage.




This article has been cited by other articles:


Home page
StrokeHome page
A. K. Wakhloo, M. J. Deleo III, and M. M. Brown
Advances in Interventional Neuroradiology
Stroke, May 1, 2009; 40(5): e305 - e312.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
R.G. Nogueira, L.H. Schwamm, and J.A. Hirsch
Endovascular Approaches to Acute Stroke, Part 1: Drugs, Devices, and Data
AJNR Am. J. Neuroradiol., April 1, 2009; 30(4): 649 - 661.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A.J. Fox, J. Millar, J. Raymond, J.C. Pryor, D. Roy, G.A. Tomlinson, J.P. McKay, and A.J. Molyneux
Dangerous Advances in Measurements from Digital Subtraction Angiography: When Is a Millimeter Not a Millimeter?
AJNR Am. J. Neuroradiol., March 1, 2009; 30(3): 459 - 461.
[Abstract] [Full Text] [PDF]