AJDRAJNR - American Journal of Neuroradiology

Published ahead of print on October 8, 2008
doi: 10.3174/ajnr.A1324

This Article
Free to Access This article has been Unlocked
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
ajnr.A1324v1
30/2/219    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by White, P.M.
Right arrow Articles by Raymond, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by White, P.M.
Right arrow Articles by Raymond, J.

Review Article

Endovascular Coiling of Cerebral Aneurysms Using "Bioactive" or Coated-Coil Technologies: A Systematic Review of the Literature

P.M. Whitea,b and J. Raymonda

a International Consortium of Neuroendovascular Centres [ICONE], Interventional Neuroradiology Research Unit, Department of Radiology, University of Montreal, CHUM Notre-Dame Hospital, Montreal, Canada
b Department of Clinical Neurosciences, Western General Hospital, Edinburgh, UK

Please address correspondence to P.M. White, MD, Consultant Neuroradiologist, Department of Neuroradiology, Western General Hospital, Edinburgh, EH4 2XU, UK; email: pmw{at}skull.dcn.ed.ac.uk

SUMMARY: Second-generation coils have been available since 2002. We wanted to assess their performance and appraise available evidence. Therefore we performed a systematic review of the literature from 2002 to 2007. There were 27 studies with a total of 2390 patients that met pre-specified inclusion criteria. All studies were classed as having a high risk of bias. There were no randomized trials and for most studies results were not independently assessed and follow-up periods were short (mean 7 months). There were large differences in demographic and aneurysm characteristics, making comparisons between coil cohorts difficult. Procedure-related morbidity and mortality were similar for all coil types. Hemorrhagic events during follow-up were few, in the range of 1%/year for all coil types. The available literature is of poor quality and clinical series provide very little evidence in favor of second-generation coils. Positive randomized trial results are needed to justify routine clinical use. This systematic review illustrates the failure of the industry, the regulatory authorities, and the neurointerventional community combined to provide a reliable and prudent approach to the introduction of new devices.




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
S. Gallas, A.C. Januel, A. Pasco, J. Drouineau, J. Gabrillargues, A. Gaston, C. Cognard, and D. Herbreteau
Long-Term Follow-Up of 1036 Cerebral Aneurysms Treated by Bare Coils: A Multicentric Cohort Treated between 1998 and 2003
AJNR Am. J. Neuroradiol., November 1, 2009; 30(10): 1986 - 1992.
[Abstract] [Full Text] [PDF]