AJDRAJNR - American Journal of Neuroradiology

Published ahead of print on January 15, 2009
doi: 10.3174/ajnr.A1434

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
ajnr.A1434v1
30/4/699    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kollia, K.
Right arrow Articles by Wanke, I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kollia, K.
Right arrow Articles by Wanke, I.

BRAIN

First Clinical Study on Ultra-High-Field MR Imaging in Patients with Multiple Sclerosis: Comparison of 1.5T and 7T

K. Kolliaa, S. Maderwalda,c, N. Putzkib, M. Schlamanna, J.M. Theysohna, O. Kraffa,c, M.E. Ladda,c, M. Forstinga and I. Wankea

a Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
b Department of Neurology, University Hospital Essen, Essen, Germany
c Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany

Please address correspondence to Kiriaki Kollia, Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstr 55, Essen, 45147, Germany; e-mail: kiriaki.kollia{at}uni-due.de

BACKGROUND AND PURPOSE: Higher magnetic field strengths and continuous improvement of high-resolution imaging in multiple sclerosis (MS) are expected to provide unique in-vivo and non-invasive insights in pathogenesis and clinical monitoring. The purpose of this study was to investigate the potential of high-resolution imaging of MS lesions in vivo comparing 7T with conventional 1.5T.

MATERIALS AND METHODS: Twelve consecutive patients with clinically definite MS were scanned on a 7T whole-body scanner and on a 1.5T Avanto. The 1.5T and 7T imaging protocol consisted of high-resolution axial proton density (PD) + T2-weighted turbo spin-echo and T2*-weighted gradient-echo (GRE), and sagittal T1-weighted 3D magnetization-prepared rapid acquisition of gradient echo.

RESULTS: The sequence parameters at 7T had to be modified because of specific absorption rate (SAR) restrictions while keeping contrast parameters equivalent to 1.5T. White matter lesions were better detected and delineated from adjacent structures at 7T compared with 1.5T. There were 42% of the patients who showed additional lesions at 7T: there were 97 white matter lesions detected on 1.5T versus 126 lesions at 7T, an increase of 23%. The perivascular migration of MS lesions was well visualized on T2*-weighted GRE sequences. In larger lesions (10 mm), a multilayer structure was revealed on T2*-weighted GRE not seen at 1.5T. Because of the higher resolution, it was possible to differentiate between juxtacortical white matter lesions and cortical lesions. There were 44% of the subcortical lesions depicted at 7T that showed cortical involvement.

CONCLUSIONS: Ultra-high-field imaging of patients with MS at 7T was well tolerated and provided better visualization of MS lesions in the gray matter and demonstrated structural abnormalities within the MS lesions themselves more effectively.




This article has been cited by other articles:


Home page
BrainHome page
K. Schmierer, H. G. Parkes, P.-W. So, S. F. An, S. Brandner, R. J. Ordidge, T. A. Yousry, and D. H. Miller
High field (9.4 Tesla) magnetic resonance imaging of cortical grey matter lesions in multiple sclerosis
Brain, January 31, 2010; (2010): awp335v1 - awp335.
[Abstract] [Full Text] [PDF]