AJDRAJNR - American Journal of Neuroradiology

Published ahead of print on February 4, 2009
doi: 10.3174/ajnr.A1468

This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
ajnr.A1468v1
30/5/900    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nakamizo, A.
Right arrow Articles by Okada, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nakamizo, A.
Right arrow Articles by Okada, Y.

BRAIN

Postoperative Evaluation of Changes in Extracranial-Intracranial Bypass Graft Using Superficial Temporal Artery Duplex Ultrasonography

A. Nakamizoa, T. Inouea, Y. Kikkawaa, K. Udaa, Y. Hirataa, K. Okamuraa, M. Yasakab and Y. Okadab

a Departments of Neurosurgery, Cerebrovascular Center and Clinical Research Institute, National Hospital Organization Kyushu Medical Center, Fukuoka, Japan
b Cerebrovascular Disease, Cerebrovascular Center and Clinical Research Institute, National Hospital Organization Kyushu Medical Center, Fukuoka, Japan

Please address correspondence to Akira Nakamizo, MD, Department of Neurosurgery, National Hospital Organization Kyushu Medical Center, 1-8-1 Jigyohama, Chuo-ku, Fukuoka 810-8563, Japan; e-mail: nakamizo{at}ns.med.kyushu-u.ac.jp

BACKGROUND AND PURPOSE: Extracranial-intracranial (ECIC) bypass grafts have been assessed postoperatively by various neuroradiologic techniques. The aim of this prospective study was to evaluate postoperative changes in ECIC bypass graft by using superficial temporal artery duplex ultrasonography (STDU). Furthermore, this study assessed the ability of STDU to predict cerebrovascular reserve capacity (CVR).

MATERIALS AND METHODS: Forty-five consecutive patients who underwent ECIC bypass procedure for atherosclerotic internal carotid artery occlusion were enrolled in this prospective study. All patients underwent single-photon emission CT and STDU preoperatively, 14 days after, 3 months after, 1 year after, and 2 years after ECIC bypass.

RESULTS: The diameter and flow velocities of the ipsilateral superficial temporal artery (STA), and regional cerebral blood flow (rCBF) showed increase during the first 2 weeks and then remained stable, whereas CVR showed a constant improvement up to 2 years after surgery. The STA diameter and mean STA flow velocity correlated significantly with CVR at 1 year after surgery (r 2 = 0.1232 and r 2 = 0.08716, respectively; P < .05). A cutoff value of 1.8 mm STA diameter was determined as the most reliable value to predict CVR greater than 10% at 1 year after surgery. The positive predictive value was calculated as 96.6%, the negative predictive value as 43.8%, the sensitivity as 75.7%, the specificity as 87.5%, and the likelihood ratio as 6.056.

CONCLUSIONS: ECIC bypass grafts can be assessed postoperatively in a noninvasive fashion with STDU. This technique provides information regarding patency as well as quantitative assessment of bypass function. Moreover, STDU is useful to predict CVR improvement.