AJDRAJNR - American Journal of Neuroradiology

This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Di Chiro, G.
Right arrow Articles by Horne, M. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Di Chiro, G.
Right arrow Articles by Horne, M. K., 3d

American Journal of Neuroradiology, Vol 7, Issue 2 193-199, Copyright © 1986 by American Society of Neuroradiology


ARTICLES

Sequential MR studies of intracerebral hematomas in monkeys

G Di Chiro, RA Brooks, ME Girton, T Caporale, DC Wright, AJ Dwyer and MK Horne 3d

It is well recognized that the MR appearance of intracranial bleeding changes with the age of lesion. It is also well known that hemoglobin in stagnating blood undergoes oxidation to methemoglobin, a substance that lowers the relaxation times of surrounding water protons. To study these phenomena in a controlled way, about 3 ml of blood was injected into the right frontal lobe of two rhesus monkeys, and they were scanned sequentially for up to 2 months in a Picker NMR scanner (Bo = 0.25-0.5 T). The image intensity of the blood changed during the first week, consistent with the lowering of T1 and T2. On the inversion- recovery scans the initial appearance of the blood was less bright than was the contralateral white matter, reversing after 3-5 days. The opposite was true on spin-echo images. T1 and T2 values were calculated for all images. In parallel experiments, several milliliters of freshly drawn blood was placed in test tubes and relaxation times were measured in a bench-top analyzer at 0.25 T over a period of 10 days. The relaxation times dropped markedly, at a rate that depended on sterility, temperature, etc., closely approaching the expected result for complete conversion of hemoglobin to methemoglobin. Ten blood samples with different methemoglobin concentrations were prepared by adding varying doses of sodium nitrite. The change in 1/T1 was found to be roughly proportional to the methemoglobin concentration for values up to 40%, and the initial slope was consistent with published data.


This article has been cited by other articles:


Home page
RadiologyHome page
T. Allkemper, B. Tombach, W. Schwindt, H. Kugel, M. Schilling, O. Debus, F. Mollmann, and W. Heindel
Acute and Subacute Intracerebral Hemorrhages: Comparison of MR Imaging at 1.5 and 3.0 T--Initial Experience
Radiology, September 1, 2004; 232(3): 874 - 881.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. J. Johnson, D. K. Kido, W. D. Shannon, M. M. Bahn, M. H. Gado, B. C. P. Lee, C. J. Moran, F. J. Wippold, and B. Littenberg
Evaluation of a Reduced MR Imaging Sequencing Protocol in Adult Patients with Stroke
Radiology, March 1, 2001; 218(3): 791 - 797.
[Abstract] [Full Text]


Home page
StrokeHome page
M. R. Patel, R. R. Edelman, and S. Warach
Detection of Hyperacute Primary Intraparenchymal Hemorrhage by Magnetic Resonance Imaging
Stroke, December 1, 1996; 27(12): 2321 - 2324.
[Abstract] [Full Text]


Home page
ANN INTERN MEDHome page
D. L. KENT and E. B. LARSON
Magnetic Resonance Imaging of the Brain and Spine: Is Clinical Efficacy Established after the First Decade?
Ann Intern Med, March 1, 1988; 108(3): 402 - 424.
[Abstract] [PDF]


Home page
Arch Otolaryngol Head Neck SurgHome page
P. M. Som, J. M. A. Shugar, K. M. Troy, M. Sacher, and A. L. Stollman
The Use of Magnetic Resonance and Computed Tomography in the Management of a Patient With Intrasinus Hemorrhage
Arch Otolaryngol Head Neck Surg, February 1, 1988; 114(2): 200 - 202.
[Abstract] [PDF]


Home page
Arch OphthalmolHome page
N. H. Kolodny, E. S. Gragoudas, D. J. D'Amico, S. J. Kohler, J. M. Seddon, E. J. Murphy, C. Yun, and D. M. Albert
Proton and Sodium 23 Magnetic Resonance Imaging of Human Ocular Tissues: A Model Study
Arch Ophthalmol, November 1, 1987; 105(11): 1532 - 1536.
[Abstract] [PDF]